This is a purely informative rendering of an RFC that includes verified errata. This rendering may not be used as a reference.

The following 'Verified' errata have been incorporated in this document: EID 4172
Network Working Group                                 R. Herriot, Editor
Request for Comments: 2910                             Xerox Corporation
Obsoletes: 2565                                                S. Butler
Category: Standards Track                                Hewlett-Packard
                                                                P. Moore
                                             Peerless Systems Networking
                                                               R. Turner
                                                               2wire.com
                                                                 J. Wenn
                                                       Xerox Corporation
                                                          September 2000


         Internet Printing Protocol/1.1: Encoding and Transport

Status of this Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (2000).  All Rights Reserved.

Abstract

   This document is one of a set of documents, which together describe
   all aspects of a new Internet Printing Protocol (IPP). IPP is an
   application level protocol that can be used for distributed printing
   using Internet tools and technologies. This document defines the
   rules for encoding IPP operations and IPP attributes into a new
   Internet mime media type called "application/ipp".  This document
   also defines the rules for transporting over Hypertext Transfer
   Protocol (HTTP) a message body whose Content-Type is
   "application/ipp". This document defines a new scheme named 'ipp' for
   identifying IPP printers and jobs.

   The full set of IPP documents includes:

   Design Goals for an Internet Printing Protocol [RFC2567]
   Rationale for the Structure and Model and Protocol for the Internet
   Printing Protocol [RFC2568]
   Internet Printing Protocol/1.1: Model and Semantics [RFC2911]
   Internet Printing Protocol/1.1: Encoding and Transport (this
   document)
   Internet Printing Protocol/1.1: Implementer's Guide [ipp-iig]
   Mapping between LPD and IPP Protocols [RFC2569]

   The document, "Design Goals for an Internet Printing Protocol", takes
   a broad look at distributed printing functionality, and it enumerates
   real-life scenarios that help to clarify the features that need to be
   included in a printing protocol for the Internet. It identifies
   requirements for three types of users: end users, operators, and
   administrators. It calls out a subset of end user requirements that
   are satisfied in IPP/1.1. A few OPTIONAL operator operations have
   been added to IPP/1.1.

   The document, "Rationale for the Structure and Model and Protocol for
   the Internet Printing Protocol", describes IPP from a high level
   view, defines a roadmap for the various documents that form the suite
   of IPP specification documents, and gives background and rationale
   for the IETF working group's major decisions.

   The document, "Internet Printing Protocol/1.1: Model and Semantics",
   describes a simplified model with abstract objects, their attributes,
   and their operations that are independent of encoding and transport.
   It introduces a Printer and a Job object. The Job object optionally
   supports multiple documents per Job. It also addresses security,
   internationalization, and directory issues.

   The document "Internet Printing Protocol/1.1: Implementer's Guide",
   gives advice to implementers of IPP clients and IPP objects.

   The document "Mapping between LPD and IPP Protocols", gives some
   advice to implementers of gateways between IPP and LPD (Line Printer
   Daemon) implementations.

Table of Contents

   1. Introduction ...................................................4
   2. Conformance Terminology ........................................4
   3. Encoding of  the Operation Layer ...............................4
      3.1  Picture of the Encoding ...................................6
         3.1.1 Request and Response...................................6
         3.1.2 Attribute Group........................................6
         3.1.3 Attribute..............................................7
         3.1.4 Picture of the Encoding of an Attribute-with-one-value.7
         3.1.5 Additional-value.......................................8
         3.1.6 Alternative Picture of the Encoding of a Request Or a
               Response...............................................9
      3.2  Syntax of Encoding ........................................9
      3.3  Attribute-group ..........................................11
      3.4  Required Parameters ......................................12
         3.4.1 Version-number........................................12
         3.4.2 Operation-id..........................................12
         3.4.3 Status-code...........................................12
         3.4.4 Request-id............................................13
      3.5  Tags .....................................................13
         3.5.1 Delimiter Tags........................................13
         3.5.2 Value Tags............................................14
      3.6  Name-Length ..............................................16
      3.7  (Attribute) Name .........................................16
      3.8  Value Length .............................................16
      3.9  (Attribute) Value ........................................17
      3.10 Data .....................................................18
   4. Encoding of Transport Layer ...................................18
      4.1  Printer-uri and job-uri ..................................19
   5. IPP URL Scheme ................................................20
   6. IANA Considerations ...........................................22
   7. Internationalization Considerations ...........................23
   8. Security Considerations .......................................23
      8.1  Security Conformance Requirements ........................23
         8.1.1 Digest Authentication.................................23
         8.1.2 Transport Layer Security (TLS)........................24
      8.2  Using IPP with TLS .......................................25
   9. Interoperability with IPP/1.0 Implementations .................25
      9.1  The "version-number" Parameter ...........................25
      9.2  Security and URL Schemes .................................26
   10. References ...................................................27
   11. Authors' Addresses ...........................................29
   12. Other Participants: ..........................................31
   13. Appendix A: Protocol Examples ................................33
      13.1 Print-Job Request ........................................33
      13.2 Print-Job Response (successful) ..........................34
      13.3 Print-Job Response (failure) .............................35

      13.4 Print-Job Response (success with attributes ignored) .....36
      13.5 Print-URI Request ........................................38
      13.6 Create-Job Request .......................................39
      13.7 Get-Jobs Request .........................................40
      13.8 Get-Jobs Response ........................................41
   14. Appendix B: Registration of MIME Media Type Information for
       "application/ipp".............................................42
   15. Appendix C: Changes from IPP/1.0 .............................44
   16. Full Copyright Statement .....................................45

1. Introduction

   This document contains the rules for encoding IPP operations and
   describes two layers: the transport layer and the operation layer.

   The transport layer consists of an HTTP/1.1 request or response. RFC
   2616 [RFC2616] describes HTTP/1.1. This document specifies the HTTP
   headers that an IPP implementation supports.

   The operation layer consists of a message body in an HTTP request or
   response.  The document "Internet Printing Protocol/1.1: Model and
   Semantics" [RFC2911] defines the semantics of such a message body and
   the supported values. This document specifies the encoding of an IPP
   operation. The aforementioned document [RFC2911] is henceforth
   referred to as the "IPP model document" or simply "model document".

   Note:  the version number of IPP (1.1) and HTTP (1.1) are not linked.
   They both just happen to be 1.1.

2. Conformance Terminology

   The key words "MUST", "MUST NOT", "REQUIRED", "SHOULD", "SHOULD NOT",
   "RECOMMENDED", "MAY", and  "OPTIONAL" in this document are to be
   interpreted as described in RFC 2119 [RFC2119].

3. Encoding of the Operation Layer

   The operation layer is the message body part of the HTTP request or
   response and it MUST contain a single IPP operation request or IPP
   operation response.  Each request or response consists of a sequence
   of values and attribute groups. Attribute groups consist of a
   sequence of attributes each of which is a name and value.  Names and
   values are ultimately sequences of octets.

   The encoding consists of octets as the most primitive type. There are
   several types built from octets, but three important types are
   integers, character strings and octet strings, on which most other
   data types are built. Every character string in this encoding MUST be

   a sequence of characters where the characters are associated with
   some charset and some natural language. A character string MUST be in
   "reading order" with the first character in the value (according to
   reading order) being the first character in the encoding. A character
   string whose associated charset is US-ASCII whose associated natural
   language is US English is henceforth called a US-ASCII-STRING. A
   character string whose associated charset and natural language are
   specified in a request or response as described in the model document
   is henceforth called a LOCALIZED-STRING.  An octet string MUST be in
   "IPP model document order" with the first octet in the value
   (according to the IPP model document order) being the first octet in
   the encoding. Every integer in this encoding MUST be encoded as a
   signed integer using two's-complement binary encoding with big-endian
   format (also known as "network order" and "most significant byte
   first"). The number of octets for an integer MUST be 1, 2 or 4,
   depending on usage in the protocol. Such one-octet integers,
   henceforth called SIGNED-BYTE, are used for the version-number and
   tag fields. Such two-byte integers, henceforth called SIGNED-SHORT
   are used for the operation-id, status-code and length fields. Four
   byte integers, henceforth called SIGNED-INTEGER, are used for value
   fields and the request-id.

   The following two sections present the encoding of the operation
   layer in two ways:

      -  informally through pictures and description
      -  formally through Augmented Backus-Naur Form (ABNF), as
         specified by RFC 2234 [RFC2234]

   An operation request or response MUST use the encoding described in
   these two sections.

3.1 Picture of the Encoding

3.1.1 Request and Response

   An operation request or response is encoded as follows:

   -----------------------------------------------
   |                  version-number             |   2 bytes  - required
   -----------------------------------------------
   |               operation-id (request)        |
   |                      or                     |   2 bytes  - required
   |               status-code (response)        |
   -----------------------------------------------
   |                   request-id                |   4 bytes  - required
   -----------------------------------------------
   |                 attribute-group             |   n bytes - 0 or more
   -----------------------------------------------
   |              end-of-attributes-tag          |   1 byte   - required
   -----------------------------------------------
   |                     data                    |   q bytes  - optional
   -----------------------------------------------

   The first three fields in the above diagram contain the value of
   attributes described in section 3.1.1 of the Model document.

   The fourth field is the "attribute-group" field, and it occurs 0 or
   more times. Each "attribute-group" field represents a single group of
   attributes, such as an Operation Attributes group or a Job Attributes
   group (see the Model document). The IPP model document specifies the
   required attribute groups and their order for each operation request
   and response.

   The "end-of-attributes-tag" field is always present, even when the
   "data" is not present.  The Model document specifies for each
   operation request and response whether the "data" field is present or
   absent.

3.1.2 Attribute Group

   Each "attribute-group" field is encoded as follows:

   -----------------------------------------------
   |           begin-attribute-group-tag         |  1 byte
   ----------------------------------------------------------
   |                   attribute                 |  p bytes |- 0 or more
   ----------------------------------------------------------

   The "begin-attribute-group-tag" field marks the beginning of an
   "attribute-group" field and its value identifies the type of
   attribute group, e.g. Operations Attributes group versus a Job
   Attributes group.  The "begin-attribute-group-tag" field also marks
   the end of the previous attribute group except for the "begin-
   attribute-group-tag" field in the first "attribute-group" field of a
   request or response.  The "begin-attribute-group-tag" field acts as
   an "attribute-group" terminator because an "attribute-group" field
   cannot nest inside another "attribute-group" field.

   An "attribute-group" field contains zero or more "attribute" fields.

   Note, the values of the "begin-attribute-group-tag" field and the
   "end-of-attributes-tag" field are called "delimiter-tags".

3.1.3 Attribute

   An "attribute" field is encoded as follows:

   -----------------------------------------------
   |          attribute-with-one-value           |  q bytes
   ----------------------------------------------------------
   |             additional-value                |  r bytes |- 0 or more
   ----------------------------------------------------------

   When an attribute is single valued (e.g. "copies" with value of 10)
   or multi-valued with one value (e.g. "sides-supported" with just the
   value 'one-sided') it is encoded with just an "attribute-with-one-
   value" field. When an attribute is multi-valued with n values (e.g.
   "sides-supported" with the values 'one-sided' and 'two-sided-long-
   edge'), it is encoded with an "attribute-with-one-value" field
   followed by n-1 "additional-value" fields.

3.1.4 Picture of the Encoding of an Attribute-with-one-value

   Each "attribute-with-one-value" field is encoded as follows:

   -----------------------------------------------
   |                   value-tag                 |   1 byte
   -----------------------------------------------
   |               name-length  (value is u)     |   2 bytes
   -----------------------------------------------
   |                     name                    |   u bytes
   -----------------------------------------------
   |              value-length  (value is v)     |   2 bytes
   -----------------------------------------------
   |                     value                   |   v bytes
   -----------------------------------------------

   An "attribute-with-one-value" field is encoded with five subfields:

      The "value-tag" field specifies the attribute syntax, e.g. 0x44
      for the attribute syntax 'keyword'.

      The "name-length" field specifies the length of the "name" field
      in bytes, e.g. u in the above diagram or 15 for the name "sides-
      supported".

      The "name" field contains the textual name of the attribute, e.g.
      "sides-supported".

      The "value-length" field specifies the length of the "value" field
      in bytes, e.g. v in the above diagram or 9 for the (keyword) value
      'one-sided'.

      The "value" field contains the value of the attribute, e.g. the
      textual value 'one-sided'.

3.1.5 Additional-value

   Each "additional-value" field is encoded as follows:

   -----------------------------------------------
   |                   value-tag                 |   1 byte
   -----------------------------------------------
   |            name-length  (value is 0x0000)   |   2 bytes
   -----------------------------------------------
   |              value-length (value is w)      |   2 bytes
   -----------------------------------------------
   |                     value                   |   w bytes
   -----------------------------------------------

   An "additional-value" is encoded with four subfields:

      The "value-tag" field specifies the attribute syntax, e.g. 0x44
      for the attribute syntax 'keyword'.

      The "name-length" field has the value of 0 in order to signify
      that it is an "additional-value". The value of the "name-length"
      field distinguishes an "additional-value" field ("name-length" is
      0) from an "attribute-with-one-value" field ("name-length" is not
      0).

      The "value-length" field specifies the length of the "value" field
      in bytes, e.g. w in the above diagram or 19 for the (keyword)
      value 'two-sided-long-edge'.

      The "value" field contains the value of the attribute, e.g. the
      textual value 'two-sided-long-edge'.

3.1.6 Alternative Picture of the Encoding of a Request Or a Response

   From the standpoint of a parser that performs an action based on a
   "tag" value, the encoding consists of:

   -----------------------------------------------
   |                  version-number             |   2 bytes  - required
   -----------------------------------------------
   |               operation-id (request)        |
   |                      or                     |   2 bytes  - required
   |               status-code (response)        |
   -----------------------------------------------
   |                   request-id                |   4 bytes  - required
   -----------------------------------------------------------
   |        tag (delimiter-tag or value-tag)     |   1 byte  |
   -----------------------------------------------           |-0 or more
   |           empty or rest of attribute        |   x bytes |
   -----------------------------------------------------------
   |              end-of-attributes-tag          |   1 byte   - required
   -----------------------------------------------
   |                     data                    |   y bytes  - optional
   -----------------------------------------------

   The following show what fields the parser would expect after each
   type of  "tag":

      -  "begin-attribute-group-tag": expect zero or more "attribute"
         fields
      -  "value-tag": expect the remainder of an "attribute-with-one-
         value" or  an "additional-value".
      -  "end-of-attributes-tag": expect that "attribute" fields are
         complete and there is optional "data"

3.2 Syntax of Encoding

   The syntax below is ABNF [RFC2234] except 'strings of literals' MUST
   be case sensitive. For example 'a' means lower case  'a' and not
   upper case 'A'.   In addition, SIGNED-BYTE and SIGNED-SHORT fields
   are represented as '%x' values which show their range of values.

      ipp-message = ipp-request / ipp-response
      ipp-request = version-number operation-id request-id
               *attribute-group end-of-attributes-tag data
      ipp-response = version-number status-code request-id
               *attribute-group end-of-attributes-tag data

      attribute-group = begin-attribute-group-tag *attribute

      version-number = major-version-number minor-version-number
      major-version-number = SIGNED-BYTE
      minor-version-number = SIGNED-BYTE

      operation-id = SIGNED-SHORT    ; mapping from model defined below
      status-code = SIGNED-SHORT  ; mapping from model defined below
      request-id = SIGNED-INTEGER ; whose value is > 0

      attribute = attribute-with-one-value *additional-value

      attribute-with-one-value = value-tag name-length name
          value-length value
      additional-value = value-tag zero-name-length value-length value

      name-length = SIGNED-SHORT    ; number of octets of 'name'
      name = LALPHA *( LALPHA / DIGIT / "-" / "_" / "." )
      value-length = SIGNED-SHORT   ; number of octets of 'value'
      value = OCTET-STRING

      data = OCTET-STRING

      zero-name-length = %x00.00            ; name-length of 0
      value-tag = %x10-FF                  ;see section 3.7.2
      begin-attribute-group-tag = %x00-02 / %04-0F ; see section 3.7.1
      end-of-attributes-tag = %x03                  ; tag of 3
                                    ; see section 3.7.1
      SIGNED-BYTE = BYTE
      SIGNED-SHORT = 2BYTE
      SIGNED-INTEGER = 4BYTE
      DIGIT = %x30-39    ;  "0" to "9"
      LALPHA = %x61-7A   ;  "a" to "z"
      BYTE = %x00-FF
      OCTET-STRING = *BYTE

   The syntax below defines additional terms that are referenced in this
   document. This syntax provides an alternate grouping of the delimiter
   tags.

      delimiter-tag = begin-attribute-group-tag  / ; see section 3.7.1
                end-of-attributes-tag
      delimiter-tag = %x00-0F                      ; see section 3.7.1

      begin-attribute-group-tag = %x00 / operation-attributes-tag /
         job-attributes-tag / printer-attributes-tag /
         unsupported-attributes-tag /  %x06-0F
      operation-attributes-tag =  %x01              ; tag of 1

      job-attributes-tag    =  %x02                 ; tag of 2
      printer-attributes-tag =  %x04                ; tag of 4
      unsupported-attributes-tag =  %x05            ; tag of 5

3.3 Attribute-group

   Each "attribute-group" field MUST be encoded with the "begin-
   attribute-group-tag" field followed by zero or more "attribute" sub-
   fields.

   The table below maps the model document group name to value of the
   "begin-attribute-group-tag" field:

      Model Document Group            "begin-attribute-group-tag" field
                                      values

      Operation Attributes            "operations-attributes-tag"
      Job Template Attributes         "job-attributes-tag"
      Job Object Attributes           "job-attributes-tag"
      Unsupported Attributes          "unsupported-attributes-tag"
      Requested Attributes            "job-attributes-tag"
      (Get-Job-Attributes)
      Requested Attributes            "printer-attributes-tag"
      (Get-Printer-Attributes)
      Document Content                in a special position as
                                      described above

   For each operation request and response, the model document
   prescribes the required and optional attribute groups, along with
   their order.  Within each attribute group, the model document
   prescribes the required and optional attributes, along with their
   order.

   When the Model document requires an attribute group in a request or
   response and the attribute group contains zero attributes, a request
   or response SHOULD encode the attribute group with the "begin-
   attribute-group-tag" field followed by zero "attribute" fields.  For
   example, if the client requests a single unsupported attribute with
   the Get-Printer-Attributes operation, the Printer MUST return no
   "attribute" fields, and it SHOULD return a "begin-attribute-group-
   tag" field for the Printer Attributes Group. The Unsupported
   Attributes group is not such an example. According to the model
   document, the Unsupported Attributes Group SHOULD be present only if
   the unsupported attributes group contains at least one attribute.

   A receiver of a request MUST be able to process the following as
   equivalent empty attribute groups:

      a) A "begin-attribute-group-tag" field with zero following
         "attribute" fields.

      b) An expected but missing "begin-attribute-group-tag" field.

   When the Model document requires a sequence of an unknown number of
   attribute groups, each of the same type, the encoding MUST contain
   one "begin-attribute-group-tag" field for each attribute group even
   when an "attribute-group" field contains zero "attribute" sub-fields.
   For example, for the Get-Jobs operation may return zero attributes
   for some jobs and not others. The "begin-attribute-group-tag" field
   followed by zero "attribute" fields tells the recipient that there is
   a job in queue for which no information is available except that it
   is in the queue.

3.4 Required Parameters

   Some operation elements are called parameters in the model document
   [RFC2911]. They MUST be encoded in a special position and they MUST
   NOT appear as operation attributes.  These parameters are described
   in the subsections below.

3.4.1 Version-number

   The "version-number" field MUST consist of a major and minor
   version-number, each of which MUST be represented by a SIGNED-BYTE.
   The major version-number MUST be the first byte of the encoding and
   the minor version-number MUST be the second byte of the encoding. The
   protocol described in this document MUST have a major version-number
   of 1 (0x01) and a minor version-number of 1 (0x01).  The ABNF for
   these two bytes MUST be %x01.01.

3.4.2 Operation-id

   The "operation-id" field MUST contain an operation-id value defined
   in the model document. The value MUST be encoded as a SIGNED-SHORT
   and it MUST be in the third and fourth bytes of the encoding of an
   operation request.

3.4.3 Status-code

   The "status-code" field MUST contain a status-code value defined in
   the model document. The value MUST be encoded as a SIGNED-SHORT and
   it MUST be in the third and fourth bytes of the encoding of an
   operation response.

   The status-code is an operation attribute in the model document. In
   the protocol, the status-code is in a special position, outside of
   the operation attributes.

   If an IPP status-code is returned, then the HTTP Status-Code MUST be
   200 (successful-ok). With any other HTTP Status-Code value, the HTTP
   response MUST NOT contain an IPP message-body, and thus no IPP
   status-code is returned.

3.4.4 Request-id

   The "request-id" field MUST contain a request-id value as defined in
   the model document. The value MUST be encoded as a SIGNED-INTEGER and
   it MUST be in the fifth through eighth bytes of the encoding.

3.5 Tags

EID 4172 (Verified) is as follows:

Section: 3.5

Original Text:

   a value that the parser treats atomically.  Values from 0x00 to
   0x37777777 are reserved for definition in future IETF standard track
   documents.  The values 0x40000000 to 0x7FFFFFFF are reserved for
   vendor extensions.

Corrected Text:

   a value that the parser treats atomically.  Values from 0x00 to
   0x3FFFFFFF are reserved for definition in future IETF Standards Track
   documents.  The values 0x40000000 to 0x7FFFFFFF are reserved for
   vendor extensions.
Notes:
There are two kinds of tags: - delimiter tags: delimit major sections of the protocol, namely attributes and data - value tags: specify the type of each attribute value 3.5.1 Delimiter Tags The following table specifies the values for the delimiter tags: Tag Value (Hex) Meaning 0x00 reserved for definition in a future IETF standards track document 0x01 "operation-attributes-tag" 0x02 "job-attributes-tag" 0x03 "end-of-attributes-tag" 0x04 "printer-attributes-tag" 0x05 "unsupported-attributes-tag" 0x06-0x0f reserved for future delimiters in IETF standards track documents When a "begin-attribute-group-tag" field occurs in the protocol, it means that zero or more following attributes up to the next delimiter tag MUST be attributes belonging to the attribute group specified by the value of the "begin-attribute-group-tag". For example, if the value of "begin-attribute-group-tag" is 0x01, the following attributes MUST be members of the Operations Attributes group. The "end-of-attributes-tag" (value 0x03) MUST occur exactly once in an operation. It MUST be the last "delimiter-tag". If the operation has a document-content group, the document data in that group MUST follow the "end-of-attributes-tag". The order and presence of "attribute-group" fields (whose beginning is marked by the "begin-attribute-group-tag" subfield) for each operation request and each operation response MUST be that defined in the model document. For further details, see section 3.7 "(Attribute) Name" and 13 "Appendix A: Protocol Examples". A Printer MUST treat a "delimiter-tag" (values from 0x00 through 0x0F) differently from a "value-tag" (values from 0x10 through 0xFF) so that the Printer knows that there is an entire attribute group that it doesn't understand as opposed to a single value that it doesn't understand. 3.5.2 Value Tags The remaining tables show values for the "value-tag" field, which is the first octet of an attribute. The "value-tag" field specifies the type of the value of the attribute. The following table specifies the "out-of-band" values for the "value-tag" field. Tag Value (Hex) Meaning 0x10 unsupported 0x11 reserved for 'default' for definition in a future IETF standards track document 0x12 unknown 0x13 no-value 0x14-0x1F reserved for "out-of-band" values in future IETF standards track documents. The following table specifies the integer values for the "value-tag" field: Tag Value (Hex) Meaning 0x20 reserved for definition in a future IETF standards track document 0x21 integer 0x22 boolean 0x23 enum 0x24-0x2F reserved for integer types for definition in future IETF standards track documents NOTE: 0x20 is reserved for "generic integer" if it should ever be needed. The following table specifies the octetString values for the "value- tag" field: Tag Value (Hex) Meaning 0x30 octetString with an unspecified format 0x31 dateTime 0x32 resolution 0x33 rangeOfInteger 0x34 reserved for definition in a future IETF standards track document 0x35 textWithLanguage 0x36 nameWithLanguage 0x37-0x3F reserved for octetString type definitions in future IETF standards track documents The following table specifies the character-string values for the "value-tag" field: Tag Value (Hex) Meaning 0x40 reserved for definition in a future IETF standards track document 0x41 textWithoutLanguage 0x42 nameWithoutLanguage 0x43 reserved for definition in a future IETF standards track document 0x44 keyword 0x45 uri 0x46 uriScheme 0x47 charset 0x48 naturalLanguage 0x49 mimeMediaType 0x4A-0x5F reserved for character string type definitions in future IETF standards track documents NOTE: 0x40 is reserved for "generic character-string" if it should ever be needed. NOTE: an attribute value always has a type, which is explicitly specified by its tag; one such tag value is "nameWithoutLanguage". An attribute's name has an implicit type, which is keyword. The values 0x60-0xFF are reserved for future type definitions in IETF standards track documents. The tag 0x7F is reserved for extending types beyond the 255 values available with a single byte. A tag value of 0x7F MUST signify that the first 4 bytes of the value field are interpreted as the tag value. Note this future extension doesn't affect parsers that are unaware of this special tag. The tag is like any other unknown tag, and the value length specifies the length of a value, which contains a value that the parser treats atomically. Values from 0x00 to 0x37777777 are reserved for definition in future IETF standard track documents. The values 0x40000000 to 0x7FFFFFFF are reserved for vendor extensions. 3.6 Name-Length The "name-length" field MUST consist of a SIGNED-SHORT. This field MUST specify the number of octets in the immediately following "name" field. The value of this field excludes the two bytes of the "name- length" field. For example, if the "name" field contains "sides", the value of this field is 5. If a "name-length" field has a value of zero, the following "name" field MUST be empty, and the following value MUST be treated as an additional value for the attribute encoded in the nearest preceding "attribute-with-one-value" field. Within an attribute group, if two or more attributes have the same name, the attribute group is mal- formed (see [RFC2911] section 3.1.3). The zero-length name is the only mechanism for multi-valued attributes. 3.7 (Attribute) Name The "name" field MUST contain the name of an attribute. The model document [RFC2911] specifies such names. 3.8 Value Length The "value-length" field MUST consist of a SIGNED-SHORT. This field MUST specify the number of octets in the immediately following "value" field. The value of this field excludes the two bytes of the "value-length" field. For example, if the "value" field contains the keyword (text) value 'one-sided', the value of this field is 9. For any of the types represented by binary signed integers, the sender MUST encode the value in exactly four octets. For any of the types represented by character-strings, the sender MUST encode the value with all the characters of the string and without any padding characters. For "out-of-band" "value-tag" fields defined in this document, such as "unsupported", the "value-length" MUST be 0 and the "value" empty; the "value" has no meaning when the "value-tag" has one of these "out-of-band" values. For future "out-of-band" "value-tag" fields, the same rule holds unless the definition explicitly states that the "value-length" MAY be non-zero and the "value" non-empty. 3.9 (Attribute) Value The syntax types (specified by the "value-tag" field) and most of the details of the representation of attribute values are defined in the IPP model document. The table below augments the information in the model document, and defines the syntax types from the model document in terms of the 5 basic types defined in section 3, "Encoding of the Operation Layer". The 5 types are US-ASCII-STRING, LOCALIZED-STRING, SIGNED-INTEGER, SIGNED-SHORT, SIGNED-BYTE, and OCTET-STRING. Syntax of Attribute Encoding Value textWithoutLanguage, LOCALIZED-STRING. nameWithoutLanguage textWithLanguage OCTET-STRING consisting of 4 fields: a. a SIGNED-SHORT which is the number of octets in the following field b. a value of type natural-language, c. a SIGNED-SHORT which is the number of octets in the following field, d. a value of type textWithoutLanguage. The length of a textWithLanguage value MUST be 4 + the value of field a + the value of field c. nameWithLanguage OCTET-STRING consisting of 4 fields: a. a SIGNED-SHORT which is the number of octets in the following field b. a value of type natural-language, c. a SIGNED-SHORT which is the number of octets in the following field d. a value of type nameWithoutLanguage. The length of a nameWithLanguage value MUST be 4 + the value of field a + the value of field c. charset, US-ASCII-STRING. naturalLanguage, mimeMediaType, keyword, uri, and uriScheme Syntax of Attribute Encoding Value boolean SIGNED-BYTE where 0x00 is 'false' and 0x01 is 'true'. integer and enum a SIGNED-INTEGER. dateTime OCTET-STRING consisting of eleven octets whose contents are defined by "DateAndTime" in RFC 1903 [RFC1903]. resolution OCTET-STRING consisting of nine octets of 2 SIGNED-INTEGERs followed by a SIGNED-BYTE. The first SIGNED-INTEGER contains the value of cross feed direction resolution. The second SIGNED-INTEGER contains the value of feed direction resolution. The SIGNED-BYTE contains the units rangeOfInteger Eight octets consisting of 2 SIGNED-INTEGERs. The first SIGNED-INTEGER contains the lower bound and the second SIGNED-INTEGER contains the upper bound. 1setOf X Encoding according to the rules for an attribute with more than 1 value. Each value X is encoded according to the rules for encoding its type. octetString OCTET-STRING The attribute syntax type of the value determines its encoding and the value of its "value-tag". 3.10 Data The "data" field MUST include any data required by the operation 4. Encoding of Transport Layer HTTP/1.1 [RFC2616] is the transport layer for this protocol. The operation layer has been designed with the assumption that the transport layer contains the following information: - the URI of the target job or printer operation - the total length of the data in the operation layer, either as a single length or as a sequence of chunks each with a length. It is REQUIRED that a printer implementation support HTTP over the IANA assigned Well Known Port 631 (the IPP default port), though a printer implementation may support HTTP over some other port as well. Each HTTP operation MUST use the POST method where the request-URI is the object target of the operation, and where the "Content-Type" of the message-body in each request and response MUST be "application/ipp". The message-body MUST contain the operation layer and MUST have the syntax described in section 3.2 "Syntax of Encoding". A client implementation MUST adhere to the rules for a client described for HTTP1.1 [RFC2616]. A printer (server) implementation MUST adhere the rules for an origin server described for HTTP1.1 [RFC2616]. An IPP server sends a response for each request that it receives. If an IPP server detects an error, it MAY send a response before it has read the entire request. If the HTTP layer of the IPP server completes processing the HTTP headers successfully, it MAY send an intermediate response, such as "100 Continue", with no IPP data before sending the IPP response. A client MUST expect such a variety of responses from an IPP server. For further information on HTTP/1.1, consult the HTTP documents [RFC2616]. An HTTP server MUST support chunking for IPP requests, and an IPP client MUST support chunking for IPP responses according to HTTP/1.1 [RFC2616]. Note: this rule causes a conflict with non-compliant implementations of HTTP/1.1 that don't support chunking for POST methods, and this rule may cause a conflict with non-compliant implementations of HTTP/1.1 that don't support chunking for CGI scripts. 4.1 Printer-uri and job-uri All Printer and Job objects are identified by a Uniform Resource Identifier (URI) [RFC2396] so that they can be persistently and unambiguously referenced. Since every URL is a specialized form of a URI, even though the more generic term URI is used throughout the rest of this document, its usage is intended to cover the more specific notion of URL as well. Some operation elements are encoded twice, once as the request-URI on the HTTP Request-Line and a second time as a REQUIRED operation attribute in the application/ipp entity. These attributes are the target URI for the operation and are called printer-uri and job-uri. Note: The target URI is included twice in an operation referencing the same IPP object, but the two URIs NEED NOT be literally identical. One can be a relative URI and the other can be an absolute URI. HTTP/1.1 allows clients to generate and send a relative URI rather than an absolute URI. A relative URI identifies a resource with the scope of the HTTP server, but does not include scheme, host or port. The following statements characterize how URLs should be used in the mapping of IPP onto HTTP/1.1: 1. Although potentially redundant, a client MUST supply the target of the operation both as an operation attribute and as a URI at the HTTP layer. The rationale for this decision is to maintain a consistent set of rules for mapping application/ipp to possibly many communication layers, even where URLs are not used as the addressing mechanism in the transport layer. 2. Even though these two URLs might not be literally identical (one being relative and the other being absolute), they MUST both reference the same IPP object. However, a Printer NEED NOT verify that the two URLs reference the same IPP object, and NEED NOT take any action if it determines the two URLs to be different. 3. The URI in the HTTP layer is either relative or absolute and is used by the HTTP server to route the HTTP request to the correct resource relative to that HTTP server. The HTTP server need not be aware of the URI within the operation request. 4. Once the HTTP server resource begins to process the HTTP request, it might get the reference to the appropriate IPP Printer object from either the HTTP URI (using to the context of the HTTP server for relative URLs) or from the URI within the operation request; the choice is up to the implementation. 5. HTTP URIs can be relative or absolute, but the target URI in the operation MUST be an absolute URI. 5. IPP URL Scheme The IPP/1.1 document defines a new scheme 'ipp' as the value of a URL that identifies either an IPP printer object or an IPP job object. The IPP attributes using the 'ipp' scheme are specified below. Because the HTTP layer does not support the 'ipp' scheme, a client MUST map 'ipp' URLs to 'http' URLs, and then follows the HTTP [RFC2616][RFC2617] rules for constructing a Request-Line and HTTP headers. The mapping is simple because the 'ipp' scheme implies all of the same protocol semantics as that of the 'http' scheme [RFC2616], except that it represents a print service and the implicit (default) port number that clients use to connect to a server is port 631. In the remainder of this section the term 'ipp-URL' means a URL whose scheme is 'ipp' and whose implicit (default) port is 631. The term 'http-URL' means a URL whose scheme is 'http', and the term 'https- URL' means a URL whose scheme is 'https', A client and an IPP object (i.e. the server) MUST support the ipp-URL value in the following IPP attributes. job attributes: job-uri job-printer-uri printer attributes: printer-uri-supported operation attributes: job-uri printer-uri Each of the above attributes identifies a printer or job object. The ipp-URL is intended as the value of the attributes in this list, and for no other attributes. All of these attributes have a syntax type of 'uri', but there are attributes with a syntax type of 'uri' that do not use the 'ipp' scheme, e.g. 'job-more-info'. If a printer registers its URL with a directory service, the printer MUST register an ipp-URL. User interfaces are beyond the scope of this document. But if software exposes the ipp-URL values of any of the above five attributes to a human user, it is REQUIRED that the human see the ipp-URL as is. When a client sends a request, it MUST convert a target ipp-URL to a target http-URL for the HTTP layer according to the following rules: 1. change the 'ipp' scheme to 'http' 2. add an explicit port 631 if the URL does not contain an explicit port. Note: port 631 is the IANA assigned Well Known Port for the 'ipp' scheme. The client MUST use the target http-URL in both the HTTP Request- Line and HTTP headers, as specified by HTTP [RFC2616] [RFC2617] . However, the client MUST use the target ipp-URL for the value of the "printer-uri" or "job-uri" operation attribute within the application/ipp body of the request. The server MUST use the ipp-URL for the value of the "printer-uri", "job-uri" or "printer-uri- supported" attributes within the application/ipp body of the response. For example, when an IPP client sends a request directly (i.e. no proxy) to an ipp-URL "ipp://myhost.com/myprinter/myqueue", it opens a TCP connection to port 631 (the ipp implicit port) on the host "myhost.com" and sends the following data: POST /myprinter/myqueue HTTP/1.1 Host: myhost.com:631 Content-type: application/ipp Transfer-Encoding: chunked ... "printer-uri" "ipp://myhost.com/myprinter/myqueue" (encoded in application/ipp message body) ... As another example, when an IPP client sends the same request as above via a proxy "myproxy.com", it opens a TCP connection to the proxy port 8080 on the proxy host "myproxy.com" and sends the following data: POST http://myhost.com:631/myprinter/myqueue HTTP/1.1 Host: myhost.com:631 Content-type: application/ipp Transfer-Encoding: chunked ... "printer-uri" "ipp://myhost.com/myprinter/myqueue" (encoded in application/ipp message body) ... The proxy then connects to the IPP origin server with headers that are the same as the "no-proxy" example above. 6. IANA Considerations This section describes the procedures for allocating encoding for the following IETF standards track extensions and vendor extensions to the IPP/1.1 Encoding and Transport document: 1. attribute syntaxes - see [RFC2911] section 6.3 2. attribute groups - see [RFC2911] section 6.5 3. out-of-band attribute values - see [RFC2911] section 6.7 These extensions follow the "type2" registration procedures defined in [RFC2911] section 6. Extensions registered for use with IPP/1.1 are OPTIONAL for client and IPP object conformance to the IPP/1.1 Encoding and Transport document. These extension procedures are aligned with the guidelines as set forth by the IESG [IANA-CON]. The [RFC2911] Section 11 describes how to propose new registrations for consideration. IANA will reject registration proposals that leave out required information or do not follow the appropriate format described in [RFC2911] Section 11. The IPP/1.1 Encoding and Transport document may also be extended by an appropriate RFC that specifies any of the above extensions. 7. Internationalization Considerations See the section on "Internationalization Considerations" in the document "Internet Printing Protocol/1.1: Model and Semantics" [RFC2911] for information on internationalization. This document adds no additional issues. 8. Security Considerations The IPP Model and Semantics document [RFC2911] discusses high level security requirements (Client Authentication, Server Authentication and Operation Privacy). Client Authentication is the mechanism by which the client proves its identity to the server in a secure manner. Server Authentication is the mechanism by which the server proves its identity to the client in a secure manner. Operation Privacy is defined as a mechanism for protecting operations from eavesdropping. 8.1 Security Conformance Requirements This section defines the security requirements for IPP clients and IPP objects. 8.1.1 Digest Authentication IPP clients MUST support: Digest Authentication [RFC2617]. MD5 and MD5-sess MUST be implemented and supported. The Message Integrity feature NEED NOT be used. IPP Printers SHOULD support: Digest Authentication [RFC2617]. MD5 and MD5-sess MUST be implemented and supported. The Message Integrity feature NEED NOT be used. The reasons that IPP Printers SHOULD (rather than MUST) support Digest Authentication are: 1. While Client Authentication is important, there is a certain class of printer devices where it does not make sense. Specifically, a low-end device with limited ROM space and low paper throughput may not need Client Authentication. This class of device typically requires firmware designers to make trade-offs between protocols and functionality to arrive at the lowest-cost solution possible. Factored into the designer's decisions is not just the size of the code, but also the testing, maintenance, usefulness, and time-to- market impact for each feature delivered to the customer. Forcing such low-end devices to provide security in order to claim IPP/1.1 conformance would not make business sense and could potentially stall the adoption of the standard. 2. Print devices that have high-volume throughput and have available ROM space have a compelling argument to provide support for Client Authentication that safeguards the device from unauthorized access. These devices are prone to a high loss of consumables and paper if unauthorized access should occur. 8.1.2 Transport Layer Security (TLS) IPP Printers SHOULD support Transport Layer Security (TLS) [RFC2246] for Server Authentication and Operation Privacy. IPP Printers MAY also support TLS for Client Authentication. If an IPP Printer supports TLS, it MUST support the TLS_DHE_DSS_WITH_3DES_EDE_CBC_SHA cipher suite as mandated by RFC 2246 [RFC2246]. All other cipher suites are OPTIONAL. An IPP Printer MAY support Basic Authentication (described in HTTP/1.1 [RFC2617]) for Client Authentication if the channel is secure. TLS with the above mandated cipher suite can provide such a secure channel. If a IPP client supports TLS, it MUST support the TLS_DHE_DSS_WITH_3DES_EDE_CBC_SHA cipher suite as mandated by RFC 2246 [RFC2246]. All other cipher suites are OPTIONAL. The IPP Model and Semantics document defines two printer attributes ("uri-authentication-supported" and "uri-security-supported") that the client can use to discover the security policy of a printer. That document also outlines IPP-specific security considerations and should be the primary reference for security implications with regard to the IPP protocol itself. For backward compatibility with IPP version 1.0, IPP clients and printers may also support SSL3 [ssl]. This is in addition to the security required in this document. 8.2 Using IPP with TLS IPP/1.1 uses the "Upgrading to TLS Within HTTP/1.1" mechanism [RFC2817]. An initial IPP request never uses TLS. The client requests a secure TLS connection by using the HTTP "Upgrade" header, while the server agrees in the HTTP response. The switch to TLS occurs either because the server grants the client's request to upgrade to TLS, or a server asks to switch to TLS in its response. Secure communication begins with a server's response to switch to TLS. 9. Interoperability with IPP/1.0 Implementations It is beyond the scope of this specification to mandate conformance with previous versions. IPP/1.1 was deliberately designed, however, to make supporting previous versions easy. It is worth noting that, at the time of composing this specification (1999), we would expect IPP/1.1 Printer implementations to: understand any valid request in the format of IPP/1.0, or 1.1; respond appropriately with a response containing the same "version-number" parameter value used by the client in the request. And we would expect IPP/1.1 clients to: understand any valid response in the format of IPP/1.0, or 1.1. 9.1 The "version-number" Parameter The following are rules regarding the "version-number" parameter (see section 3.3): 1. Clients MUST send requests containing a "version-number" parameter with a '1.1' value and SHOULD try supplying alternate version numbers if they receive a 'server-error-version-not- supported' error return in a response. 2. IPP objects MUST accept requests containing a "version-number" parameter with a '1.1' value (or reject the request for reasons other than 'server-error-version-not-supported'). 3. It is recommended that IPP objects accept any request with the major version '1' (or reject the request for reasons other than 'server-error-version-not-supported'). See [RFC2911] "versions" sub-section. 4. In any case, security MUST NOT be compromised when a client supplies a lower "version-number" parameter in a request. For example, if an IPP/1.1 conforming Printer object accepts version '1.0' requests and is configured to enforce Digest Authentication, it MUST do the same for a version '1.0' request. 9.2 Security and URL Schemes The following are rules regarding security, the "version-number" parameter, and the URL scheme supplied in target attributes and responses: 1. When a client supplies a request, the "printer-uri" or "job- uri" target operation attribute MUST have the same scheme as that indicated in one of the values of the "printer-uri- supported" Printer attribute. 2. When the server returns the "job-printer-uri" or "job-uri" Job Description attributes, it SHOULD return the same scheme ('ipp', 'https', 'http', etc.) that the client supplied in the "printer-uri" or "job-uri" target operation attributes in the Get-Job-Attributes or Get-Jobs request, rather than the scheme used when the job was created. However, when a client requests job attributes using the Get-Job-Attributes or Get-Jobs operations, the jobs and job attributes that the server returns depends on: (1) the security in effect when the job was created, (2) the security in effect in the query request, and (3) the security policy in force. 3. It is recommended that if a server registers a non-secure ipp- URL with a directory service (see [RFC2911] "Generic Directory Schema" Appendix), then it also register an http-URL for interoperability with IPP/1.0 clients (see section 9). 4. In any case, security MUST NOT be compromised when a client supplies an 'http' or other non-secure URL scheme in the target "printer-uri" and "job-uri" operation attributes in a request. 10. References [dpa] ISO/IEC 10175 Document Printing Application (DPA), June 1996. [iana] IANA Registry of Coded Character Sets: ftp://ftp.isi.edu/in-notes/iana/assignments/character- sets. [IANA-CON] Narten, T. and H. Alvestrand, "Guidelines for Writing an IANA Considerations Section in RFCs", BCP 26, RFC 2434, October 1998. [ipp-iig] Hastings, Tom, et al., "Internet Printing Protocol/1.1: Implementer's Guide", Work in Progress. [RFC822] Crocker, D., "Standard for the Format of ARPA Internet Text Messages", STD 11, RFC 822, August 1982. [RFC1123] Braden, S., "Requirements for Internet Hosts - Application and Support", STD 3, RFC 1123, October, 1989. [RFC1179] McLaughlin, L. III, (editor), "Line Printer Daemon Protocol", RFC 1179, August 1990. [RFC2223] Postel, J. and J. Reynolds, "Instructions to RFC Authors", RFC 2223, October 1997. [RFC1738] Berners-Lee, T., Masinter, L. and M. McCahill, "Uniform Resource Locators (URL)", RFC 1738, December 1994. [RFC1759] Smith, R., Wright, F., Hastings, T., Zilles, S. and J. Gyllenskog, "Printer MIB", RFC 1759, March 1995. [RFC1766] Alvestrand, H., "Tags for the Identification of Languages", RFC 1766, March 1995. [RFC1808] Fielding, R., "Relative Uniform Resource Locators", RFC 1808, June 1995. [RFC1903] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Textual Conventions for Version 2 of the Simple Network Management Protocol (SNMPv2)", RFC 1903, January 1996. [RFC2046] Freed, N. and N. Borenstein, "Multipurpose Internet Mail Extensions (MIME) Part Two: Media Types", RFC 2046, November 1996. [RFC2048] Freed, N., Klensin, J. and J. Postel, "Multipurpose Internet Mail Extension (MIME) Part Four: Registration Procedures", BCP 13, RFC 2048, November 1996. [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, March 1997. [RFC2184] Freed, N. and K. Moore, "MIME Parameter Value and Encoded Word Extensions: Character Sets, Languages, and Continuations", RFC 2184, August 1997. [RFC2234] Crocker, D. and P. Overall, "Augmented BNF for Syntax Specifications: ABNF", RFC 2234, November 1997. [RFC2246] Dierks, T. and C. Allen, "The TLS Protocol", RFC 2246. January 1999. [RFC2396] Berners-Lee, T., Fielding, R. and L. Masinter, "Uniform Resource Identifiers (URI): Generic Syntax", RFC 2396, August 1998. [RFC2565] Herriot, R., Butler, S., Moore, P. and R. Turner, "Internet Printing Protocol/1.0: Encoding and Transport", RFC 2565, April 1999. [RFC2566] deBry, R., Hastings, T., Herriot, R., Isaacson, S. and P. Powell, "Internet Printing Protocol/1.0: Model and Semantics", RFC 2566, April 1999. [RFC2567] Wright, D., "Design Goals for an Internet Printing Protocol", RFC2567, April 1999. [RFC2568] Zilles, S., "Rationale for the Structure and Model and Protocol for the Internet Printing Protocol", RFC 2568, April 1999. [RFC2569] Herriot, R., Hastings, T., Jacobs, N. and J. Martin, "Mapping between LPD and IPP Protocols", RFC 2569, April 1999. [RFC2616] Fielding, R., Gettys, J., Mogul, J., Frystyk, H., Masinter, L., Leach, P. and T. Berners-Lee, "Hypertext Transfer Protocol - HTTP/1.1", RFC 2616, June 1999. [RFC2617] Franks, J., Hallam-Baker, P., Hostetler, J., Lawrence, S., Leach, P., Luotonen, A. and L. Stewart, "HTTP Authentication: Basic and Digest Access Authentication", RFC 2617, June 1999. [RFC2817] Khare, R. and S. Lawrence, "Upgrading to TLS Within HTTP/1.1", RFC 2817, May 2000. [RFC2910] Herriot, R., Butler, S., Moore, P., Turner, R. and J. Wenn, "Internet Printing Protocol/1.1: Encoding and Transport", RFC 2910, September 2000. [RFC2911] Hastings, T., Herriot, R., deBry, R., Isaacson, S. and P. Powell, "Internet Printing Protocol/1.1: Model and Semantics", RFC 2911, September 2000. [SSL] Netscape, The SSL Protocol, Version 3, (Text version 3.02), November 1996. 11. Authors' Addresses Robert Herriot, Editor Xerox Corporation 3400 Hillview Ave., Bldg #1 Palo Alto, CA 94304 Phone: 650-813-7696 Fax: 650-813-6860 EMail: robert.herriot@pahv.xerox.com Sylvan Butler Hewlett-Packard 11311 Chinden Blvd. Boise, ID 83714 Phone: 208-396-6000 Fax: 208-396-3457 EMail: sbutler@boi.hp.com Paul Moore Peerless Systems Networking 10900 NE 8th St #900 Bellevue, WA 98004 Phone: 425-462-5852 EMail: pmoore@peerless.com Randy Turner 2Wire, Inc. 694 Tasman Dr. Milpitas, CA 95035 Phone: 408-546-1273 John Wenn Xerox Corporation 737 Hawaii St El Segundo, CA 90245 Phone: 310-333-5764 Fax: 310-333-5514 EMail: jwenn@cp10.es.xerox.com IPP Web Page: http://www.pwg.org/ipp/ IPP Mailing List: ipp@pwg.org To subscribe to the ipp mailing list, send the following email: 1) send it to majordomo@pwg.org 2) leave the subject line blank 3) put the following two lines in the message body: subscribe ipp end 12. Other Participants: Chuck Adams - Tektronix Shivaun Albright - HP Stefan Andersson - Axis Jeff Barnett - IBM Ron Bergman - Hitachi Koki Imaging Dennis Carney - IBM Systems Keith Carter - IBM Angelo Caruso - Xerox Rajesh Chawla - TR Computing Nancy Chen - Okidata Solutions Josh Cohen - Microsoft Jeff Copeland - QMS Andy Davidson - Tektronix Roger deBry - IBM Maulik Desai - Auco Mabry Dozier - QMS Lee Farrell - Canon Information Satoshi Fujitami - Ricoh Systems Steve Gebert - IBM Sue Gleeson - Digital Charles Gordon - Osicom Brian Grimshaw - Apple Jerry Hadsell - IBM Richard Hart - Digital Tom Hastings - Xerox Henrik Holst - I-data Stephen Holmstead Zhi-Hong Huang - Zenographics Scott Isaacson - Novell Babek Jahromi - Microsoft Swen Johnson - Xerox David Kellerman - Northlake Software Robert Kline - TrueSpectra Charles Kong - Panasonic Carl Kugler - IBM Dave Kuntz - Hewlett-Packard Takami Kurono - Brother Rick Landau - Digital Scott Lawrence - Agranot Systems Greg LeClair - Epson Dwight Lewis - Lexmark Harry Lewis - IBM Tony Liao - Vivid Image Roy Lomicka - Digital Pete Loya - HP Ray Lutz - Cognisys Mike MacKay - Novell, Inc. David Manchala - Xerox Carl-Uno Manros - Xerox Jay Martin - Underscore Stan McConnell - Xerox Larry Masinter - Xerox Sandra Matts - Hewlett Packard Peter Michalek - Shinesoft Ira McDonald - High North Inc. Mike Moldovan - G3 Nova Tetsuya Morita - Ricoh Yuichi Niwa - Ricoh Pat Nogay - IBM Ron Norton - Printronics Hugo Parra, Novell Bob Pentecost - Hewlett-Packard Patrick Powell - Astart Jeff Rackowitz - Intermec Technologies Eric Random - Peerless Rob Rhoads - Intel Xavier Riley - Xerox Gary Roberts - Ricoh David Roach - Unisys Stuart Rowley - Kyocera Yuji Sasaki - Japan Computer Richard Schneider - Epson Industry Kris Schoff - HP Katsuaki Sekiguchi - Canon Information Systems Bob Setterbo - Adobe Gail Songer - Peerless Hideki Tanaka - Cannon Information Devon Taylor - Novell, Inc. Systems Mike Timperman - Lexmark Atsushi Uchino - Epson Shigeru Ueda - Canon Bob Von Andel - Allegro Software William Wagner - NetSilicon/DPI Jim Walker - DAZEL Chris Wellens - Interworking Labs Trevor Wells - Hewlett Packard Craig Whittle - Sharp Labs Rob Whittle - Novell, Inc. Jasper Wong - Xionics Don Wright - Lexmark Michael Wu - Heidelberg Digital Rick Yardumian - Xerox Michael Yeung - Canon Information Lloyd Young - Lexmark Systems Atsushi Yuki - Kyocera Peter Zehler - Xerox William Zhang - Canon Information Frank Zhao - Panasonic Systems Steve Zilles - Adobe Rob Zirnstein - Canon Information Systems 13. Appendix A: Protocol Examples 13.1 Print-Job Request The following is an example of a Print-Job request with job-name, copies, and sides specified. The "ipp-attribute-fidelity" attribute is set to 'true' so that the print request will fail if the "copies" or the "sides" attribute are not supported or their values are not supported. Octets Symbolic Value Protocol field 0x0101 1.1 version-number 0x0002 Print-Job operation-id 0x00000001 1 request-id 0x01 start operation-attributes operation-attributes-tag 0x47 charset type value-tag 0x0012 name-length attributes- attributes-charset name charset 0x0008 value-length us-ascii US-ASCII value 0x48 natural-language type value-tag 0x001B name-length attributes- name natural- attributes-natural-language language 0x0005 value-length en-us en-US value 0x45 uri type value-tag 0x000B name-length printer-uri printer-uri name 0x0015 value-length ipp://forest/ printer pinetree value pinetree 0x42 nameWithoutLanguage type value-tag 0x0008 name-length job-name job-name name 0x0006 value-length foobar foobar value 0x22 boolean type value-tag 0x0016 name-length ipp-attribute- ipp-attribute-fidelity name fidelity 0x0001 value-length 0x01 true value Octets Symbolic Value Protocol field 0x02 start job-attributes job-attributes-tag 0x21 integer type value-tag 0x0006 name-length copies copies name 0x0004 value-length 0x00000014 20 value 0x44 keyword type value-tag 0x0005 name-length sides sides name 0x0013 value-length two-sided- two-sided-long-edge value long-edge 0x03 end-of-attributes end-of-attributes-tag %!PS... <PostScript> data 13.2 Print-Job Response (successful) Here is an example of a successful Print-Job response to the previous Print-Job request. The printer supported the "copies" and "sides" attributes and their supplied values. The status code returned is 'successful-ok'. Octets Symbolic Value Protocol field 0x0101 1.1 version-number 0x0000 successful-ok status-code 0x00000001 1 request-id 0x01 start operation-attributes operation-attributes-tag 0x47 charset type value-tag 0x0012 name-length attributes- attributes-charset name charset 0x0008 value-length us-ascii US-ASCII value 0x48 natural-language type value-tag 0x001B name-length attributes- attributes-natural- name natural-language language 0x0005 value-length en-us en-US value 0x41 textWithoutLanguage type value-tag 0x000E name-length status-message status-message name 0x000D value-length Octets Symbolic Value Protocol field successful-ok successful-ok value 0x02 start job-attributes job-attributes-tag 0x21 integer value-tag 0x0006 name-length job-id job-id name 0x0004 value-length 147 147 value 0x45 uri type value-tag 0x0007 name-length job-uri job-uri name 0x0019 value-length ipp://forest/ job 123 on pinetree value pinetree/123 0x23 enum type value-tag 0x0009 name-length job-state job-state name 0x0004 value-length 0x0003 pending value 0x03 end-of-attributes end-of-attributes-tag 13.3 Print-Job Response (failure) Here is an example of an unsuccessful Print-Job response to the previous Print-Job request. It fails because, in this case, the printer does not support the "sides" attribute and because the value '20' for the "copies" attribute is not supported. Therefore, no job is created, and neither a "job-id" nor a "job-uri" operation attribute is returned. The error code returned is 'client-error- attributes-or-values-not-supported' (0x040B). 0x0101 1.1 version-number 0x040B client-error-attributes-or- status-code values-not-supported 0x00000001 1 request-id 0x01 start operation-attributes operation-attributes tag 0x47 charset type value-tag 0x0012 name-length attributes- attributes-charset name charset 0x0008 value-length us-ascii US-ASCII value Octets Symbolic Value Protocol field 0x48 natural-language type value-tag 0x001B name-length attributes- attributes-natural-language name natural- language 0x0005 value-length en-us en-US value 0x41 textWithoutLanguage type value-tag 0x000E name-length status- status-message name message 0x002F value-length client-error- value attributes- values-not-supported or-values- client-error-attributes-or- not-supported 0x05 start unsupported-attributes unsupported-attributes tag 0x21 integer type value-tag 0x0006 name-length copies copies name 0x0004 value-length 0x00000014 20 value 0x10 unsupported (type) value-tag 0x0005 name-length sides sides name 0x0000 value-length 0x03 end-of-attributes end-of-attributes-tag 13.4 Print-Job Response (success with attributes ignored) Here is an example of a successful Print-Job response to a Print-Job request like the previous Print-Job request, except that the value of 'ipp-attribute-fidelity' is false. The print request succeeds, even though, in this case, the printer supports neither the "sides" attribute nor the value '20' for the "copies" attribute. Therefore, a job is created, and both a "job-id" and a "job-uri" operation attribute are returned. The unsupported attributes are also returned in an Unsupported Attributes Group. The error code returned is 'successful-ok-ignored-or-substituted-attributes' (0x0001). Octets Symbolic Value Protocol field 0x0101 1.1 version-number 0x0001 successful-ok-ignored-or- status-code Octets Symbolic Value Protocol field substituted-attributes 0x00000001 1 request-id 0x01 start operation-attributes operation-attributes-tag 0x47 charset type value-tag 0x0012 name-length attributes- attributes-charset name charset 0x0008 value-length us-ascii US-ASCII value 0x48 natural-language type value-tag 0x001B name-length attributes- attributes-natural- name natural-language language 0x0005 value-length en-us en-US value 0x41 textWithoutLanguage type value-tag 0x000E name-length status-message status-message name 0x002F value-length successful-ok- successful-ok-ignored-or- value ignored-or- substituted-attributes substituted- attributes 0x05 start unsupported- unsupported-attributes attributes tag 0x21 integer type value-tag 0x0006 name-length copies copies name 0x0004 value-length 0x00000014 20 value 0x10 unsupported (type) value-tag 0x0005 name-length sides sides name 0x0000 value-length 0x02 start job-attributes job-attributes-tag 0x21 integer value-tag 0x0006 name-length job-id job-id name 0x0004 value-length 147 147 value 0x45 uri type value-tag 0x0007 name-length job-uri job-uri name 0x0019 value-length ipp://forest/ job 123 on pinetree value pinetree/123 Octets Symbolic Value Protocol field 0x23 enum type value-tag 0x0009 name-length job-state job-state name 0x0004 value-length 0x0003 pending value 0x03 end-of-attributes end-of-attributes-tag 13.5 Print-URI Request The following is an example of Print-URI request with copies and job-name parameters: Octets Symbolic Value Protocol field 0x0101 1.1 version-number 0x0003 Print-URI operation-id 0x00000001 1 request-id 0x01 start operation-attributes operation-attributes-tag 0x47 charset type value-tag 0x0012 name-length attributes- attributes-charset name charset 0x0008 value-length us-ascii US-ASCII value 0x48 natural-language type value-tag 0x001B name-length attributes- attributes-natural-language name natural- language 0x0005 value-length en-us en-US value 0x45 uri type value-tag 0x000B name-length printer-uri printer-uri name 0x0015 value-length ipp://forest/ printer pinetree value pinetree 0x45 uri type value-tag 0x000C name-length document-uri document-uri name 0x0011 value-length ftp://foo.com ftp://foo.com/foo value Octets Symbolic Value Protocol field /foo 0x42 nameWithoutLanguage type value-tag 0x0008 name-length job-name job-name name 0x0006 value-length foobar foobar value 0x02 start job-attributes job-attributes-tag 0x21 integer type value-tag 0x0006 name-length copies copies name 0x0004 value-length 0x00000001 1 value 0x03 end-of-attributes end-of-attributes-tag 13.6 Create-Job Request The following is an example of Create-Job request with no parameters and no attributes: Octets Symbolic Value Protocol field 0x0101 1.1 version-number 0x0005 Create-Job operation-id 0x00000001 1 request-id 0x01 start operation-attributes operation-attributes-tag 0x47 charset type value-tag 0x0012 name-length attributes- attributes-charset name charset 0x0008 value-length us-ascii US-ASCII value 0x48 natural-language type value-tag 0x001B name-length attributes- attributes-natural-language name natural- language 0x0005 value-length en-us en-US value 0x45 uri type value-tag 0x000B name-length printer-uri printer-uri name 0x0015 value-length ipp://forest/ printer pinetree value pinetree Octets Symbolic Value Protocol field inetree 0x03 end-of-attributes end-of-attributes-tag 13.7 Get-Jobs Request The following is an example of Get-Jobs request with parameters but no attributes: Octets Symbolic Value Protocol field 0x0101 1.1 version-number 0x000A Get-Jobs operation-id 0x00000123 0x123 request-id 0x01 start operation-attributes operation-attributes-tag 0x47 charset type value-tag 0x0012 name-length attributes- attributes-charset name charset 0x0008 value-length us-ascii US-ASCII value 0x48 natural-language type value-tag 0x001B name-length attributes- attributes-natural-language name natural- language 0x0005 value-length en-us en-US value 0x45 uri type value-tag 0x000B name-length printer-uri printer-uri name 0x0015 value-length ipp://forest/ printer pinetree value pinetree 0x21 integer type value-tag 0x0005 name-length limit limit name 0x0004 value-length 0x00000032 50 value 0x44 keyword type value-tag 0x0014 name-length requested- requested-attributes name attributes 0x0006 value-length Octets Symbolic Value Protocol field job-id job-id value 0x44 keyword type value-tag 0x0000 additional value name-length 0x0008 value-length job-name job-name value 0x44 keyword type value-tag 0x0000 additional value name-length 0x000F value-length document-format document-format value 0x03 end-of-attributes end-of-attributes-tag 13.8 Get-Jobs Response The following is an of Get-Jobs response from previous request with 3 jobs. The Printer returns no information about the second job (because of security reasons): Octets Symbolic Value Protocol field 0x0101 1.1 version-number 0x0000 successful-ok status-code 0x00000123 0x123 request-id (echoed back) 0x01 start operation-attributes operation-attributes-tag 0x47 charset type value-tag 0x0012 name-length attributes- attributes-charset name charset 0x000A value-length ISO-8859-1 ISO-8859-1 value 0x48 natural-language type value-tag 0x001B name-length attributes- attributes-natural-language name natural- language 0x0005 value-length en-us en-US value 0x41 textWithoutLanguage type value-tag 0x000E name-length status-message status-message name 0x000D value-length successful-ok successful-ok value 0x02 start job-attributes (1st job-attributes-tag Octets Symbolic Value Protocol field object) 0x21 integer type value-tag 0x0006 name-length job-id job-id name 0x0004 value-length 147 147 value 0x36 nameWithLanguage value-tag 0x0008 name-length job-name job-name name 0x000C value-length 0x0005 sub-value-length fr-ca fr-CA value 0x0003 sub-value-length fou fou name 0x02 start job-attributes (2nd job-attributes-tag object) 0x02 start job-attributes (3rd job-attributes-tag object) 0x21 integer type value-tag 0x0006 name-length job-id job-id name 0x0004 value-length 148 149 value 0x36 nameWithLanguage value-tag 0x0008 name-length job-name job-name name 0x0012 value-length 0x0005 sub-value-length de-CH de-CH value 0x0009 sub-value-length isch guet isch guet name 0x03 end-of-attributes end-of-attributes-tag 14. Appendix B: Registration of MIME Media Type Information for "application/ipp" This appendix contains the information that IANA requires for registering a MIME media type. The information following this paragraph will be forwarded to IANA to register application/ipp whose contents are defined in Section 3 "Encoding of the Operation Layer" in this document: MIME type name: application MIME subtype name: ipp A Content-Type of "application/ipp" indicates an Internet Printing Protocol message body (request or response). Currently there is one version: IPP/1.1, whose syntax is described in Section 3 "Encoding of the Operation Layer" of [RFC2910], and whose semantics are described in [RFC2911]. Required parameters: none Optional parameters: none Encoding considerations: IPP/1.1 protocol requests/responses MAY contain long lines and ALWAYS contain binary data (for example attribute value lengths). Security considerations: IPP/1.1 protocol requests/responses do not introduce any security risks not already inherent in the underlying transport protocols. Protocol mixed-version interworking rules in [RFC2911] as well as protocol encoding rules in [RFC2910] are complete and unambiguous. Interoperability considerations: IPP/1.1 requests (generated by clients) and responses (generated by servers) MUST comply with all conformance requirements imposed by the normative specifications [RFC2911] and [RFC2910]. Protocol encoding rules specified in [RFC2910] are comprehensive, so that interoperability between conforming implementations is guaranteed (although support for specific optional features is not ensured). Both the "charset" and "natural-language" of all IPP/1.1 attribute values which are a LOCALIZED-STRING are explicit within IPP protocol requests/responses (without recourse to any external information in HTTP, SMTP, or other message transport headers). Published specifications: [RFC2911] Hastings, T., Herriot, R., deBry, R., Isaacson, S. and P. Powell, "Internet Printing Protocol/1.1: Model and Semantics", RFC 2911, September 2000. [RFC2910] Herriot, R., Butler, S., Moore, P., Turner, R. and J. Wenn, "Internet Printing Protocol/1.1: Encoding and Transport", RFC 2910, September 2000. Applications which use this media type: Internet Printing Protocol (IPP) print clients and print servers, communicating using HTTP/1.1 (see [RFC2910]), SMTP/ESMTP, FTP, or other transport protocol. Messages of type "application/ipp" are self-contained and transport-independent, including "charset" and "natural-language" context for any LOCALIZED-STRING value. Person & email address to contact for further information: Tom Hastings Xerox Corporation 737 Hawaii St. ESAE-231 El Segundo, CA Phone: 310-333-6413 Fax: 310-333-5514 EMail: hastings@cp10.es.xerox.com or Robert Herriot Xerox Corporation 3400 Hillview Ave., Bldg #1 Palo Alto, CA 94304 Phone: 650-813-7696 Fax: 650-813-6860 EMail: robert.herriot@pahv.xerox.com Intended usage: COMMON 15. Appendix C: Changes from IPP/1.0 IPP/1.1 is identical to IPP/1.0 [RFC2565] with the follow changes: 1. Attributes values that identify a printer or job object use a new 'ipp' scheme. The 'http' and 'https' schemes are supported only for backward compatibility. See section 5. 2. Clients MUST support of Digest Authentication, IPP Printers SHOULD support Digest Authentication. See Section 8.1.1 3. TLS is recommended for channel security. In addition, SSL3 may be supported for backward compatibility. See Section 8.1.2 4. It is recommended that IPP/1.1 objects accept any request with major version number '1'. See section 9.1. 5. IPP objects SHOULD return the URL scheme requested for "job- printer-uri" and "job-uri" Job Attributes, rather than the URL scheme used to create the job. See section 9.2. 6. The IANA and Internationalization sections have been added. The terms "private use" and "experimental" have been changed to "vendor extension". The reserved allocations for attribute group tags, attribute syntax tags, and out-of-band attribute values have been clarified as to which are reserved to future IETF standards track documents and which are reserved to vendor extension. Both kinds of extensions use the type2 registration procedures as defined in [RFC2911]. 7. Clarified that future "out-of-band" value definitions may use the value field if additional information is needed. Full Copyright Statement Copyright (C) The Internet Society (2000). All Rights Reserved. This document and translations of it may be copied and furnished to others, and derivative works that comment on or otherwise explain it or assist in its implementation may be prepared, copied, published and distributed, in whole or in part, without restriction of any kind, provided that the above copyright notice and this paragraph are included on all such copies and derivative works. However, this document itself may not be modified in any way, such as by removing the copyright notice or references to the Internet Society or other Internet organizations, except as needed for the purpose of developing Internet standards in which case the procedures for copyrights defined in the Internet Standards process must be followed, or as required to translate it into languages other than English. The limited permissions granted above are perpetual and will not be revoked by the Internet Society or its successors or assigns. This document and the information contained herein is provided on an "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Acknowledgement Funding for the RFC Editor function is currently provided by the Internet Society.

mirror server hosted at Truenetwork, Russian Federation.