Network Working Group                                       N. Brownlee
Request for Comments: 2123                   The University of Auckland
Category: Informational                                      March 1997


          Traffic Flow Measurement:  Experiences with NeTraMet

Status of this Memo

   This memo provides information for the Internet community.  This memo
   does not specify an Internet standard of any kind.  Distribution of
   this memo is unlimited.

Abstract

   This memo records experiences in implementing and using the Traffic
   Flow Measurement Architecture and Meter MIB. It discusses the
   implementation of NeTraMet (a traffic meter) and NeMaC (a combined
   manager and meter reader), considers the writing of meter rule sets
   and gives some guidance on setting up a traffic flow measurement
   system using NeTraMet.

Table of Contents

 1 Introduction                                                        2
   1.1 NeTraMet structure and development . . . . . . . . . . . . . .  3
   1.2 Scope of this document . . . . . . . . . . . . . . . . . . . .  4
 2 Implementation                                                      4
   2.1 Choice of meter platform . . . . . . . . . . . . . . . . . . .  4
   2.2 Programming support requirements . . . . . . . . . . . . . . .  5
     2.2.1 DOS environment  . . . . . . . . . . . . . . . . . . . . .  6
     2.2.2 Unix environment . . . . . . . . . . . . . . . . . . . . .  7
   2.3 Implementing the meter . . . . . . . . . . . . . . . . . . . .  7
     2.3.1 Data structures  . . . . . . . . . . . . . . . . . . . . .  7
     2.3.2 Packet matching  . . . . . . . . . . . . . . . . . . . . .  8
     2.3.3 Testing groups of rule addresses . . . . . . . . . . . . .  8
     2.3.4 Compression of address masks . . . . . . . . . . . . . . .  9
     2.3.5 Ignoring unwanted flow data  . . . . . . . . . . . . . . . 10
     2.3.6 Observing meter reader activity  . . . . . . . . . . . . . 11
     2.3.7 Meter memory management  . . . . . . . . . . . . . . . . . 12
   2.4 Data collection  . . . . . . . . . . . . . . . . . . . . . . . 14
   2.5 Restarting a meter . . . . . . . . . . . . . . . . . . . . . . 15
   2.6 Performance  . . . . . . . . . . . . . . . . . . . . . . . . . 16
 3 Writing rule sets                                                  16
   3.1 Rule set to observe all flows  . . . . . . . . . . . . . . . . 17
   3.2 Specifying flow direction, using computed attributes . . . . . 18
   3.3 Subroutines  . . . . . . . . . . . . . . . . . . . . . . . . . 21
   3.4 More complicated rule sets . . . . . . . . . . . . . . . . . . 23



Brownlee                     Informational                      [Page 1]


RFC 2123                Traffic Flow Measurement              March 1997


 4 Flow data files                                                    26
   4.1 Sample flow data file  . . . . . . . . . . . . . . . . . . . . 27
   4.2 Flow data file features  . . . . . . . . . . . . . . . . . . . 28
   4.3 Terminating and restarting meter reading . . . . . . . . . . . 29
 5 Analysis applications                                              30
 6 Using NeTraMet in a measurement system                             31
   6.1 Examples of NeTraMet in production use . . . . . . . . . . . . 31
 7 Acknowledgments                                                    33
 8 References                                                         33
 9 Security Considerations                                            34
10 Author's Address                                                   34

1 Introduction

   Early in 1992 my University needed to develop a system for recovering
   the costs of its Internet traffic.  In March of that year I attended
   the Internet Accounting Working Group's session at the San Diego
   IETF, where I was delighted to find that the Group had produced a
   detailed architecture for measuring network traffic and were waiting
   for someone to try implementing it.

   During 1992 I produced a prototype measurement system, using balanced
   binary trees to store information about traffic flows.  This work was
   reported at the Washington IETF in November 1992.  The prototype
   performed well, but it made no attempt to recover memory from old
   flows, and the overheads in managing the balanced trees proved to be
   unacceptably high.  I moved on to develop a production-quality
   system, this time using hash tables to index the flow information.

   This version was called NeTraMet (the Network Traffic Meter), and was
   released as free software in October 1993.  Since then I have
   continued working on NeTraMet, producing new releases two or three
   times each year.  NeTraMet is now in production use at many sites
   around the world.  It is difficult to estimate the number of sites,
   but there is an active NeTraMet mailing list, which had about 130
   subscribers in March 1996.

   Early in 1996 the Realtime Traffic Flow Measurement Working Group
   (RTFM) was chartered to move the Traffic Flow Measurement
   Architecture on to the IETF standards track.  This document records
   traffic flow measurement experience gained through three years
   experience with NeTraMet.









Brownlee                     Informational                      [Page 2]


RFC 2123                Traffic Flow Measurement              March 1997


1.1 NeTraMet structure and development

   The Traffic Flow Architecture document [1] describes four components:

     - METERS, which are attached to the network at the points where
       it is desired to measure the traffic,

     - METER READERS, which read data from meters and store it for later
       use,

     - MANAGERS, which configure meters and control meter readers, and

     - ANALYSIS APPLICATIONS, which process the data from meter readers
       so as to produce whatever reports are required.

   NeTraMet is a computer program which implements the Traffic Meter,
   stores the measured flow data in memory, and provides an SNMP agent
   so as to make it available to Meter Readers.  The NeTraMet
   distribution files include NeMaC, which is a combined Manager and
   Meter Reader capable of managing an arbitrary number of meters, each
   of which may be using its own rule set, and having its flow data
   collected at its own specified intervals.  The NeTraMet distribution
   also includes several rudimentary Analysis Applications, allowing
   users to produce simple plots from NeMaC's flow data files (fd_filter
   and fd_extract) and to monitor - in real time - the flows at a remote
   meter (nm_rc and nifty).

   Since the first release the Traffic Meter MIB [2] has been both
   improved and simplified.  Significant changes have included better
   ways to specify traffic flows (i.e. more actions and better control
   structures for the Packet Matching Engine), and computed attributes
   (class and kind).  These changes have been prompted by operational
   requirements at sites using NeTraMet, and have been tested
   extensively in successive versions of NeTraMet.

   NeTraMet is widely used to collect usage data for Internet Service
   Providers.  This is especially so in Australia and New Zealand, but
   there are also active users at sites around the world, for example in
   Canada, France, Germany and Poland.

   NeTraMet is very useful as a tool for understanding exactly where
   traffic is flowing in large networks.  Since the Traffic Meters
   perform considerable data reduction (as specified by their rule sets)
   they significantly reduce the volume of data to be read by Meter
   Readers.  This characteristic makes NeTraMet particularly effective
   for networks with many remote sites.  An example of this (the
   Kawaihiko network) is briefly described below.




Brownlee                     Informational                      [Page 3]


RFC 2123                Traffic Flow Measurement              March 1997


   As well as providing data for post-observation analysis, NeTraMet can
   be used for real-time network monitoring and trouble-shooting.  The
   NeTraMet distribution includes 'nifty,' an X/Motif application which
   monitors traffic flows and attempts to highlight those which are
   'interesting.'

1.2 Scope of this document

   This document presents the experience gained from three years work
   with the Traffic Flow Measurement Architecture.  Its contents are
   grouped as follows

     - Implementation issues for NeTraMet and NeMaC,

     - How rule files work, and how to write them for particular
       purposes, and

     - How to use NeTraMet and NeMaC for short-term and long-term flow
       measurement.

2 Implementation

2.1 Choice of meter platform

   As pointed out in the Architecture document [1], the goal of the
   Realtime Traffic Flow Measurement Working Group is to develop a
   standard for the Traffic Meter, with the goal of seeing it
   implemented in network devices such as hubs, switches and routers.
   Until the Architecture is well enough developed to allow this, it has
   sufficed to implement the meter as a program running on a general-
   purpose computer system.

   The choice of computer system for NeTraMet was driven by the need to
   choose one which would be widely available within the Internet
   community.  One strong possibility was a Unix system, since these are
   commonly used for a variety of network support and management tasks.
   For the initial implementation, however, Unix would have had some
   disadvantages:

     - The wide variety of different Unix systems can increase the
       difficulties of software support.

     - The cost of a Unix system as a meter is too high to allow users
       to run meters simultaneously at many points within their
       networks.






Brownlee                     Informational                      [Page 4]


RFC 2123                Traffic Flow Measurement              March 1997


   Another factor in choosing the platform was system performance.  When
   I first started implementing NeTraMet it was impossible to predict
   how much processing workload was needed for a viable meter.
   Similarly, I had no idea how much memory would be required for code
   or data.  I therefore chose to implement NeTraMet on a DOS PC. This
   was because:

     - It is a minimum system in all respects.  If the meter works
       well on such a system, it can be implemented on almost any
       hardware (including routers, switches, etc.)

     - It is an inexpensive system.  Sites can easily afford to have
       many meters around their networks.

     - It is a simple system, and one which I had complete control over.
       This allowed me to implement effective instrumentation to monitor
       the meter's performance, and to include a wide variety of
       performance optimisations in the code.

   Once the meter was running I needed a manager to download rule files
   to it.  Since a single manager and meter reader can effectively
   support a large number of meters, a Unix environment for NeMaC was a
   natural choice.  There are fewer software support problems for NeMaC
   than for NeTraMet since NeMaC has minimal support needs - it only
   needs to open a UDP socket to the SNMP port on each controlled meter.

   Early NeTraMet distributions contained only the PC meter and Unix
   manager.  In later releases I ported NeTraMet (the meter) to Unix,
   and extended the control features of NeMaC (the combined manager and
   meter reader).  I have also experimented with porting NeMaC to the
   DOS system.  This is not difficult, but doesn't seem to be worth
   pursuing.

   The current version of NeTraMet is a production-quality traffic
   measurement system which has been in continuous use at the University
   of Auckland for nearly two years.

2.2 Programming support requirements

   To implement the Traffic Flow Meter I needed a programming
   environment providing good support for the following:

     - observation of packet headers on the network;

     - system timer with better than 10 ms resolution;

     - IP (Internet Protocol), for communications with manager and meter
       reader;



Brownlee                     Informational                      [Page 5]


RFC 2123                Traffic Flow Measurement              March 1997


     - SNMP, for the agent implementing the Meter MIB.

2.2.1 DOS environment

   For the PC I chose to use Ethernet as the physical network medium.
   This is simply an initial choice, being the medium used within the
   University of Auckland's data network.  Interfaces for other media
   could easily be added as they are needed.

   In the PC environment a variety of 'generalised' network interfaces
   are available.  I considered those available from companies such as
   Novell, DEC and Microsoft and decided against them, partly because
   they are proprietary, and partly because they did not appear to be
   particularly easy to use.  Instead I chose the CRYNWR Packet Drivers
   [3] .  These are available for a wide variety of interface cards and
   are simple and clearly documented.  They support Ethernet's
   promiscuous mode, allowing one to observe headers for every passing
   packet in a straightforward manner.  One disadvantage of the Packet
   Drivers is that it is harder to use them with newer user shells (such
   as Microsoft Windows), but this was irrelevant since I intended to
   run the meter as the only program on a dedicated machine.

   Timing on the PC presented a challenge since the BIOS timer routines
   only provide a clock tick about 18 times each second, which limits
   the available time resolution.  Initially I made do with a timing
   resolution of one second for packets, since I believed that most
   flows existed for many seconds.  In recent years it has become
   apparent that many flows have lifetimes well under a second.  To
   measure them properly with the Traffic Flow Meter one needs times
   resolved to 10 millisecond intervals, this being the size of
   TimeTicks, the most common time unit within SNMP [4].  Since all the
   details of the original PC are readily available [5], it was not
   difficult to understand the underlying hardware.  I have written PC
   timer routines for NeTraMet which read the hardware timer with 256
   times the resolution of the DOS clock ticks, i.e. about 5 ticks per
   millisecond.

   There are many TCP/IP implementations available for DOS, but most of
   them are commercial software.  Instead I chose Waterloo TCP [6],
   since this was available (including full source code) as public
   domain software.  This was necessary since I needed to modify it to
   allow me to save incoming packet headers at the same time as
   forwarding packets destined for the meter to the IP handler routines.
   For SNMP I chose CMU SNMP [7], since again this was available (with
   full source code) as public domain software.  This made it fairly
   simple to port it from Unix to the PC.





Brownlee                     Informational                      [Page 6]


RFC 2123                Traffic Flow Measurement              March 1997


   Finally, for the NeTraMet development I used Borland's Turbo C and
   Turbo Assembler.  Although many newer C programming environments are
   now available, I have been perfectly happy with Turbo C version 2 for
   the NeTraMet project!

2.2.2 Unix environment

   In implementing the Unix meter, the one obvious problem was 'how do I
   get access to packet headers?'  Early versions of the Unix meter were
   implemented using various system-specific interfaces on a SunOS 4.2
   system.  Later versions use libpcap [8], which provides a portable
   method of obtaining access to packet headers on a wide range of Unix
   systems.  I have verified that this works very well for ethernet
   interfaces on Solaris, SunOS, Irix, DEC Unix and Linux, and for FDDI
   interfaces on Solaris.  libpcap provides timestamps for each packet
   header with resolution determined by the system clock, which is
   certainly better than 10 ms!

   All Unix systems provide TCP/IP capabilities, so that was not an
   issue.  For SNMP I used CMU SNMP, exactly as on the PC.

2.3 Implementing the meter

   This section briefly discusses the data structures used by the meter,
   and the packet matching process.  One very strong concern during the
   evolution of NeTraMet has been the need for the highest possible
   level of meter performance.  A variety of interesting optimisations
   have been developed to achieve this; as discussed below.  Another
   particular concern was the need for efficient and effective memory
   managent; this is discussed in detail below.

2.3.1 Data structures

   All the programs in NeTraMet, NeMaC and their supporting utility
   programs are written in C, partly because C and its run-time
   libraries provides good access to the underlying hardware, and partly
   because I have found it to be a highly portable language.














Brownlee                     Informational                      [Page 7]


RFC 2123                Traffic Flow Measurement              March 1997


   The data for each flow is stored in a C structure.  The structure
   includes all the flow's attribute values (including packet and byte
   counts), together with a link field which can be used to link flows
   into lists.  NeTraMet assumes that Adjacent addresses are 802 MAC
   Addresses, which are all six bytes long.  Similarly, Transport
   addresses are assumes to be two bytes long, which is the case for
   port numbers in IP.  Peer addresses are normally four bytes or less
   in length.  They may, however, be as long as 20 bytes (for CLNS). I
   have chosen to use a fixed Peer address size, defined at compile
   time, so as to avoid the complexity of having variable-sized flow
   structures.

   The flow table itself is an array of pointers to flow data
   structures, which allows indexed access to flows via their flow
   numbers.  There is also a single large hash table, referred to in the
   Architecture document [1] as the flow table's 'search index'.  Each
   hash value in the table points to a circular chain of flows.  To find
   a flow one computes its hash value then searches that value's flow
   chain.

   The meter stores each rule in a C structure.  All the rule components
   have fixed sizes, but address fields must be wide enough to hold any
   type of address - Adjacent, Peer or Transport.  The rule address
   width is defined at compile time, in the same way as flow Peer
   addresses.  Each rule set is implemented as an array of pointers to
   rule data structures, and the rule table is an array of pointers to
   the rule sets.  The size of each rule set is specified by NeMaC
   (before it begins downloading the rule set), but the maximum number
   of rule sets is defined at compile time.

2.3.2 Packet matching

   Packet matching is carried out in NeTraMet exactly as described in
   the Architecture document [1].  Each incoming packet header is
   analysed so as to determine its attribute values.  These values are
   stored in a structure which is passed to the Packet Matching Engine.
   To facilitate matching with source and destination reversed this
   structure contains two substructures, one containing the source
   Adjacent, Peer and Transport address values, the other containing the
   destination address values.

2.3.3 Testing groups of rule addresses

   As described in the Architecture [1] each rule's address will usually
   be tested, i.e. ANDed with the rule's mask and compared with the
   rule's value.  If the comparison fails, the next rule in sequence is
   executed.  This allows one to write rule sets which use a group of
   rules to test an incoming packet to see whether one of its addresses



Brownlee                     Informational                      [Page 8]


RFC 2123                Traffic Flow Measurement              March 1997


   - e.g. its SourcePeerAddress - is one of a set of specified IP
   addresses.  Such groups of related rules can grow quite large,
   containing hundreds of rules.  It was clear that sequential execution
   of such groups of rules would be slow, and that something better was
   essential.

   The optimisation implemented in NeTraMet is to find groups of rules
   which test the same attribute with the same mask, and convert them
   into a single hashed search of their values.  The overhead of setting
   up hash tables (one for each group) is incurred once, just before the
   meter starts running a new rule set.  When a 'group' test is to be
   performed, the meter ANDs the incoming attribute value, computes a
   hash value from it, and uses this to search the group's hash table.
   Early tests showed that the rule hash chains were usually very short,
   usually having only one or two members.  The effect is to reduce
   large sequences of tests to a hash computation and lookup, with a
   very small number of compares; in short this is an essential
   optimisation for any traffic meter!

   There is, of course, overhead associated with performing the hashed
   compare.  NeTraMet handles this by having a minimum group size
   defined at compile time.  If the group is too small it is not
   combined into a hashed group.

   In early versions of NeTraMet I did not allow Gotos into a hashed
   group of rules, which proved to be an unnecessarily conservative
   position.  NeTraMet stores each group's hash table in a separate
   memory area, and keeps a pointer to the hash table in the first rule
   of the group.  (The rules data structure has an extra component to
   hold this hash table pointer).  Rules within the group don't have
   hash table pointers; when they are executed as the target of a Goto
   rule they behave as ordinary rules, i.e. their tests are performed
   normally.

2.3.4 Compression of address masks

   When the Packet Matching Engine has decided that an incoming packet
   belongs to a flow which is to be measured, it searches the flow table
   to determine whether or not the flow is already present.  It does
   this by computing a hash from the packet and using it for access to
   the flow table's search index.

   When designing a hash table, one normally assumes that the objects in
   the table have a constant size.  For NeTraMet's flow table this would
   mean that each flow would contain a value for every attribute.  This,
   however, is not the case, since only those attribute values 'pushed'
   by rules during packet matching are stored for a flow.




Brownlee                     Informational                      [Page 9]


RFC 2123                Traffic Flow Measurement              March 1997


   To demonstrate this problem , let us assume that every flow in the
   table contains a value for only one attribute, SourcePeerAddress, and
   that the rule set decides whether flows belong to a specified list of
   IP networks, in which case only their network numbers are pushed.
   The rules perform this test using a variety of masks, since the
   network number allocations range from 16 to 24 bits in width.  In
   searching the flow table, the meter must distinguish between zeroes
   in the address and 'don't care' bits which had been ANDed out.  To
   achieve this it must store SourcePeerMask values in the flow table as
   well as the ANDed SourcePeerAddress values.

   In early versions of NeTraMet this problem was side-stepped by using
   multiple hash tables and relying on the user to write rules which
   used the same set of attributes and masks for all the flows in each
   table.  This was effective, but clumsy and difficult to explain.
   Later versions changed to using a single hash table, and storing the
   mask values for all the address attributes in each flow.

   The current version of the meter stores the address masks in
   compressed form.  After examining a large number of rule sets I
   realised that although a rule set may have many rules, it usually has
   a very small number of address masks.  It is a simple matter to build
   a table of address masks, and store an index to this 'mask table'
   instead of a complete mask.  NeTraMet's maximum number of masks is
   defined at compile time, up to a maximum of 256.  This allows me to
   use a single byte for each mask in the flow data structure,
   significantly reducing the structure's size.  As well as this size
   reduction, two masks can be compared by comparing their indices in
   the mask table, i.e. it reduces to a single-byte comparison.
   Overall, using a mask table seems to provide useful improvements in
   storage efficiency and execution speed.

2.3.5 Ignoring unwanted flow data

   As described in the Architecture document [1], every incoming packet
   is tested against the current rule set by the Packet Matching Engine.
   This section explains my efforts to improve NeTraMet performance on
   the PC by reducing the amount of processing required by each incoming
   packet.

   On the PC each incoming packet causes an interrupt, which NeTraMet
   must process so as to collect information about the packet.  In early
   versions I used a ring buffer with 512 slots for packet headers, and
   simply copied each packet's first 64 bytes into the next free slot.
   The packet headers were later taken from the buffer, attribute values
   were extracted from them, and the resulting 'incoming attribute
   values' records were passed to the Packet Matching Engine.




Brownlee                     Informational                     [Page 10]


RFC 2123                Traffic Flow Measurement              March 1997


   I modified the interrupt handling code to extract the attribute
   values and store them in a 'buffer slot.'  This reduced the amount of
   storage required in each slot, allowing more space for storing flows.
   It did increase slightly the amount of processing done for each
   packet interrupt, but this has not caused any problems.

   In later versions I realised that if one is only interested in
   measuring IP packets, there is no point in storing (and later
   processing) Novell or EtherTalk packets!  It is a simple matter for
   the meter to inspect a rule set and determine which Peer types are of
   interest.  If there are PushRule rules which test SourcePeerType (or
   DestPeerType), they specify which types are of interest.  If there
   are no such rules, every packet type is of interest.  The PC NeTraMet
   has a set of Boolean variables, one for each protocol it can handle.
   The values of these 'protocol' variables are determined when the
   meter begins running a new rule set.  For each incoming packet, the
   interrupt handler determines the Peer type.  If the protocol is not
   of interest, no further processing is done - the packet is simply
   ignored.  In a similar manner, if Adjacent addresses are never tested
   there is no point in copying them into the packet buffer slot.

   The overall effect of these optimisations is most noticeable for rule
   files which measure IP flows on a network segment which also carries
   a lot of traffic for other network protocols; this situation is
   common on multiprotocol Local Area networks.  On the Unix version of
   NeTraMet the Operating System does all the packet interrupt
   processing, and libpcap [8] delivers packet headers directly to
   NeTraMet.  The 'protocol' and 'adjacent address' optimisations are
   still performed, at the point when NeTraMet receives the packet
   headers from libpcap.

2.3.6 Observing meter reader activity

   The Architecture document [1] explains that a flow data record must
   be held in the meter until its data has been read by a meter reader.
   A meter must therefore have a reliable way of deciding when flow data
   has been read.  The problem is complicated by the fact that there may
   be more than one meter reader, and that meter readers collect their
   data asynchronously.












Brownlee                     Informational                     [Page 11]


RFC 2123                Traffic Flow Measurement              March 1997


   Early versions of NeTraMet solved this problem by having a single MIB
   variable which a meter reader could set to indicate that it was
   beginning a data collection.  In response to such an SNMP SET
   request, NeTraMet would update its 'collectors' table.  This had an
   entry for each meter reader, and variables recording the start time
   for the last two collections.  The most recent collection might still
   be in progress, but its start time provides a safe estimate of the
   time when the one before it actually finished.  Space used for flows
   which have been idle since the penultimate collection started can be
   recovered by the meter's garbage collector, as described below.

   The Meter MIB [2] specifies a more general table of meter reader
   information.  A meter reader wishing to collect data from a meter
   must inform the meter of its intention by creating a row in the
   table, then setting a LastTime variable in that row to indicate the
   start of a collection.  The meter handles such a SET request exactly
   as described above.  If there are multiple meter readers the meter
   can easily find the earliest time any of them started its penultimate
   collection, and may recover flows idle since then.  Should a meter
   reader fail, NeTraMet will eventually time out its entry in the meter
   reader info table, and delete it.  This avoids a situation where the
   meter can't recover flows until they have been collected by several
   meter readers, one of which has failed.

2.3.7 Meter memory management

   In principle, the size of the flow table (i.e. the maximum number of
   flows) could be changed dynamically.  This would involve allocating
   space for the flow table's new pointer array and copying the old
   pointers into it.  NeTraMet does not implement this.  Instead the
   maximum number of flows is set from the command line when it starts
   execution.  If no maximum is specified, a compile-time default number
   is used.

   Memory for flow data structures (i.e. 'flows') is allocated
   dynamically.  NeTraMet requests the C run-time system for blocks of
   several hundred flows, and links them into a free list.  When a new
   flow is needed NeTraMet gets memory space from the free list, then
   searches the flow table's pointer array for an unused flow pointer.
   In practice a 'last-allocated' index is used to point to the flow
   table, so a simple linear search suffices.  The flow index is saved
   in the flow's data record, and its other attribute values are set to
   zero.








Brownlee                     Informational                     [Page 12]


RFC 2123                Traffic Flow Measurement              March 1997


   To release a flow data record it must first be removed from any hash
   list it is part of - this is straightforward since those lists are
   circular.  The flow's entry in the flow table pointer array is then
   set to zero (NULL pointer), and its space is returned to the free
   list.

   Once a flow data record is created it could continue to exist
   indefinitely.  In time, however, the meter would run out of space.
   To deal with this problem NeTraMet uses an incremental garbage
   collector to reclaim memory.

   At regular intervals specified by a 'GarbageCollectInterval' variable
   the garbage collector procedure is invoked.  This searches through
   the flow table looking for flows which might be recovered.  To
   control the resources consumed by garbage collection there are limits
   on the number of in-use and idle flows which the garbage collector
   may inspect  these are set either when NeTraMet is started (as
   options on the command line) or dynamically by NeMaC (using variables
   in an Enterprise MIB for NeTraMet)

   To decide whether a flow can be recovered, the garbage collector
   considers how long it has been idle (no packets in either direction),
   and when its data was last collected.  If it has been collected by
   all known meter readers since its LastTime, its memory may be
   recovered.  This alogrithm is implemented using a variable called
   'GarbageCollectTime,' which normally contains the meter's UpTime when
   the penultimate collection (i.e. the one before last) was started.
   See the section on observing meter reader activity (above) for more
   details.

   Should flows not be collected often enough the meter could run out of
   space.  NeTraMet attempts to prevent this by having a low-priority
   background process check the percentage of flows active and compare
   it with the HighWaterMark MIB variable.  If the percentage of active
   flows is greater than the high-water mark, 'GarbageCollectTime' is
   incremented by the current value of the InactivityTimeout MIB
   variable.

   The Meter MIB [2] specifies that a meter should switch to using a
   'standby' rule set if the percentage of active flows rises above
   HighWaterMark.  In using NeTraMet to measure traffic flows to and
   from the University of Auckland it has not been difficult to create
   standby rules which are very similar to the 'production' rule file,
   differing only in that they push much less information about flows.
   This has, on several occasions, allowed the meter to continue running
   for one or two days after the meter reader failed.  When the meter
   reader restarted, it was able to collect all the accumulated flow
   data!



Brownlee                     Informational                     [Page 13]


RFC 2123                Traffic Flow Measurement              March 1997


   The MIB also specifies that the meter should take some action when
   the active flow percentage rises above its FloodMark value.  If this
   were not done, the meter could spend a rapidly increasing proportion
   of its time garbage collecting, to the point where its ability to
   respond to requests from its manager would be compromised.  NeTraMet
   switches to the default rule set when its FloodMark is reached.

   A potentially large number of new flows may be created when the meter
   switches to a standby rule set.  It is important to set a
   HighWaterMark so as to allow enough flow table space for this.  In
   practice, a HighWaterMark of 65% and a FloodMark of 95% seem to work
   well.

2.4 Data collection

   As explained above, a meter reader wishing to collect flows begins
   each collection by setting the LastTime variable in its
   ReaderInfoTable row, then works its way through the flow table
   collecting data.  A number of algorithms can be used to examine the
   flow table; these are presented below.

   The simplest approach is a linear scan of the table, reading the
   LastTime variable for each row.  If the read fails the row is
   inactive.  If it succeeds, it is of interest if its LastTime value is
   greater than the time of the last collection.  Although this method
   is simple it is also rather slow, requiring an SNMP GET request for
   every possible flow; this renders it impractical.

   Early versions of NeTraMet used two 'windows' into the flow table to
   find flows which were of interest.  Both windows were SNMP tables,
   indexed by a variable which specified a time.  A succession of
   GETNEXT requests on one of these windows allowed NeMaC (the meter
   reader) to find the flow indices for all flows which had been active
   since the specified time.  The two windows were the ActivityTime
   window (which located active flows), and the CreateTime window (which
   located new flows).  Knowing the index of an active flow, the meter
   reader can GET the values for all the attributes of interest.  NeMaC
   allows the user to specify which these are, rather than simply read
   all the attributes.

   Having the two windows allowed NeMaC to read attributes which remain
   constant - such as the flow's address attributes - when the flow is
   created, but to only read attributes which change with time - such as
   its packet and byte counts - during later collections.  Experience
   has shown, however, that many flows have rather short lifetimes; one
   effect of this is that the improved efficiency of using two windows
   does not result in any worthwhile improvement in collection
   performance.



Brownlee                     Informational                     [Page 14]


RFC 2123                Traffic Flow Measurement              March 1997


   The current version of the Meter MIB [2] uses a TimeFilter variable
   in the flow table entries.  This can be used with GETNEXT requests to
   find all flows which have been active since a specified time
   directly, without requiring the extra 'window' SNMP variables.  It
   can be combined with SNMPv2's GETBULK request to further reduce the
   number of SNMP packets needed for each collection; I have yet to
   implement this in NeTraMet.

   A disadvantage of using SNMP to collect data from the meter is that
   SNMP packets impose a high overhead.  For example, if we wish to read
   an Integer32 variable (four bytes of data), it will be returned with
   its object identifier, type and length, i.e. at least ten bytes of
   superfluous data.  One way to reduce this overhead is to use an
   Opaque object to return a collection of data.  NeTraMet uses this
   approach to retrieve 'column activity data' from the meter, as
   follows.

   Each packet of column activity data contains data values for a
   specified attribute, and each value is preceded by its flow number.
   The flow table can be regarded as a two-dimensional array, with a
   column for each flow attribute.  Column activity data objects allow
   the meter reader to read columns of the flow table, so as to collect
   only those attributes specified by the user.  The actual
   implementation is complicated by the fact that since the flow table
   is read column by column, rows can become active after the first
   column has been read.  NeMaC reads the widest columns (those with
   greatest size in bytes, e.g. PeerAddress) first, and ignores any rows
   which appear in later columns.  Newly active rows will, of course, be
   read in the next collection.

   Using Opaque objects in this way dramatically reduces the number of
   SNMP packets required to read a meter.  This has proved worthwhile in
   situations where the number of flows is large (for example on busy
   LANs), and where the meter(s) are physically dispersed over slow WAN
   links.  It has the disadvantage that general-purpose MIB browsers
   cannot understand the column activity variables, but this seems a
   small price to pay for the improved data collection performance.

2.5 Restarting a meter

   If a meter fails, for example because of a power failure, it will
   restart and begin running rule set 1, the default rule set which is
   built into the meter.  Its manager must recognise that this has
   happened, and respond with some suitable action.

   NeMaC allows the user to specify a 'keepalive' interval.  After every
   such interval NeMaC reads the meter's sysUptime and compares it with
   the last sysUptime.  If the new sysUptime is less than the last one,



Brownlee                     Informational                     [Page 15]


RFC 2123                Traffic Flow Measurement              March 1997


   NeMaC decides that the meter has restarted.  It downloads the meter's
   backup rule set and production rule set, then requests the meter to
   start running the production rule set.  In normal use we use a
   keepalive interval of five minutes and a collection interval of 15
   minutes.  If a meter restarts, we lose up to five minutes data before
   the rules sets are downloaded.

   Having the meter run the default rule set on startup is part of the
   Traffic Flow Measurement Architecture [1], in keeping with the notion
   that meters are very simple devices which do not have disk storage.
   Since disks are now very cheap, it may be worth considering whether
   the architecture should allow a meter to save its configuration
   (including rule sets) on disk.

2.6 Performance

   The PC version of the meter, NeTraMet, continually measures how much
   processor time is being used.  Whenever there is no incoming packet
   data to process, 'dummy' packets are generated and placed in the
   input buffer.  These packets are processed normally by the Packet
   Matching Engine; they have a PeerType of 'dummy.'  The numbers of
   dummy and normal packets are counted by the meter; their ratio is
   used as an estimate of the processor time which is 'idle,' i.e. not
   being used to process incoming packets.  The Unix version is intended
   to run as a process in a multiprocessing system, so it cannot busy-
   wait in this way.

   The meter also collects several other performance measures; these can
   be displayed on the meter console in response to keyboard requests.

   The PC meter can be used with a 10 MHz 286 machine, on which it can
   handle a steady load of about 750 packets per second.  On a 25 MHz
   386SX it will handle about 1250 packets per second.  Users have
   reported that a 40 MHz 486 can handle peaks of about 3,000 packets
   per second without packet loss.  The Unix meter has been tested
   metering traffic on a (lightly loaded) FDDI interface; it uses about
   one percent of the processor time on a SPARC 10 system running
   Solaris.

3 Writing rule sets

   The Traffic Meter provides a versatile device for measuring a user-
   specified set of traffic flows, and performing useful data reduction
   on them.  This data reduction capability not only minimises the
   volume of data to be collected by meter readers, but also simplifies
   the later processing of traffic flow data.





Brownlee                     Informational                     [Page 16]


RFC 2123                Traffic Flow Measurement              March 1997


   The flows of interest, and the processing to be performed, are
   specified in a 'rule set' which is downloaded to the meter (NeTraMet)
   by the manager (NeMaC). This section explains what is involved in
   writing rule sets.

   NeTraMet is limited to metering packets observed on a network
   segment.  This means that for all the observed flows, Source and Dest
   Type attributes (e.g. SourcePeerType and DestPeerType) have the same
   value.

   The NeTraMet implementation uses single variables in its flow data
   structure for AdjacentType, SourceType and TransType.  Nonetheless,
   the rule sets discussed below push values for both Source and Dest
   Type attributes; this make sure that packet matching works properly
   with the directions reversed, even for a meter which allows Source
   and Dest Type values to be different.

3.1 Rule set to observe all flows

   NeMaC reads rule sets from text files which contain the rules, the
   set number which the meter (and meter reader) will identify them by,
   and a 'format,' i.e. a list specifying which attributes the meter
   reader should collect and write to the flow data file.  The #
   character indicates the start of a comment; NeMaC ignores the rest of
   the line.

     SET 2
     #
     RULES
     #
       SourcePeerType & 255 = Dummy:   Ignore, 0;
       Null & 0 = 0:  GotoAct, Next;
     #
       SourcePeerType     & 255             = 0: PushPkttoAct, Next;
       DestPeerType       & 255             = 0: PushPkttoAct, Next;
       SourcePeerAddress  & 255.255.255.255 = 0: PushPkttoAct, Next;
       DestPeerAddress    & 255.255.255.255 = 0: PushPkttoAct, Next;
       SourceTransType    & 255             = 0: PushPkttoAct, Next;
       DestTransType      & 255             = 0: PushPkttoAct, Next;
       SourceTransAddress & 255.255         = 0: PushPkttoAct, Next;
       DestTransAddress   & 255.255         = 0: CountPkt, 0;
     #
     FORMAT FlowRuleSet FlowIndex FirstTime "  "
        SourcePeerType SourcePeerAddress DestPeerAddress "  "
        SourceTransType SourceTransAddress DestTransAddress "  "
        ToPDUs FromPDUs "  " ToOctets FromOctets;





Brownlee                     Informational                     [Page 17]


RFC 2123                Traffic Flow Measurement              March 1997


   The first rule tests the incoming packet's SourcePeerType to see
   whether it is 'dummy.'  If it is, the packet is ignored, otherwise
   the next rule is executed.

   The second rule tests the Null attribute.  Such a test always
   succeeds, so the rule simply jumps to the action of the next rule.
   (The keyword 'next' is converted by NeMaC into the number of the
   following rule.)

   The third rule pushes the packet's SourcePeerType value, then jumps
   to the action of the next rule.  The user does not know in advance
   what the value of PushPkt rules will be, which is why the value
   appearing in them is always zero.  The user must take care not to
   write rule sets which try to perform the test in a PushPkt rule.
   This is a very common error in a rule set, so NeMaC tests for it and
   displays an error message.

   The following rules push a series of attribute values from the
   packet, and the last rule also Counts the packet, i.e. it tells the
   Packet Matching Engine (PME) that the packet has been successfully
   matched.  The PME responds by searching the flow table to see whether
   the flow is already current (i.e. in the table), creating a new flow
   data record for it should this be necessary, and incrementing its
   packet and byte counters.

   Overall this rule set simply classifies the packet (i.e. decides
   whether or not it is to be counted), then pushes all the Peer and
   Transport attribute values for it.  It makes no attempt to specify a
   direction for the flow - this is left to the PME, as described in
   [1].  The resulting flow data file will have each flow's source and
   destination addresses in the order of the first packet the meter
   observed for the flow.

3.2 Specifying flow direction, using computed attributes

   As indicated above, the Packet Matching Engine will reliably
   determine the flow, and the direction within that flow, for every
   packet seen by a meter.  If the rule set does not specify a direction
   for the flow, the PME simply assumes that the first packet observed
   for a flow is travelling forward, i.e. from source to destination.
   In later analysis of the flow data, however, one is usually
   interested in traffic to or from a particular source.

   One can achieve this in a simple manner by writing a rule set to
   specify the source for flows.  All that is required is to have rules
   which succeed if the packet is travelling in the required direction,
   and which execute a 'Fail' action otherwise.  This is demonstrated in
   the following two examples.



Brownlee                     Informational                     [Page 18]


RFC 2123                Traffic Flow Measurement              March 1997


   (Note that early versions of NeMaC allowed 'Retry' as a synonym for
   'Fail.'  The current version also allows 'NoMatch,' which seems a
   better way to imply "fail, allowing PME to try a second match with
   directions reversed.")

     #  Count IP packets from network 130.216.0.0
     #
     SourcePeerType & 255 = IP: Pushto, ip_pkt;
     Null & 0 = 0: Ignore, 0;
     #
     ip_pkt:
       SourcePeerAddress & 255.255.0.0 = 130.216.0.0: Goto c_pkt;
       Null & 0 = 0: NoMatch, 0;
     #
     c_pkt:
       SourcePeerAddress & 255.255.255.255 = 0: PushPkttoAct, Next;
       DestPeerAddress & 255.255.255.255 = 0: CountPkt, 0;

   The rule labelled ip_pkt tests whether the packet came from network
   130.216.  If it did not, the test fails and the following rule
   executes a NoMatch action, causing the PME to retry the match with
   the directions reversed.  If the second match fails the packet did
   not have 130.216 as an end-point, and is ignored.

   The next rule set meters IP traffic on a network segment which
   connects two routers, g1 and g2.  It classifies flows into three
   groups - those travelling from g1 to g2, those whose source is g1 and
   those whose source is g2.























Brownlee                     Informational                     [Page 19]


RFC 2123                Traffic Flow Measurement              March 1997


     #  Count IP packets between two gateways
     #
     #     -------+-------------------+------------------+-------
     #            |                   |                  |
     #       +----+-----+        +----+-----+        +---+---+
     #       |   g1     |        |    g2    |        | meter |
     #       +-+-+-+-+--+        +-+-+-+-+--+        +-------+
     #
     SourcePeerType & 255 = IP: Pushto, ip_pkt;
     Null & 0 = 0: Ignore, 0;
     #
     ip_pkt:
       SourceAdjacentAddress & FF-FF-FF-FF-FF-FF = 00-80-48-81-0E-7C:
           Goto, s1;
       Null & 0 = 0: Goto, s2;
     s1:
       DestAdjacentAddress & FF-FF-FF-FF-FF-FF = 02-07-01-04-ED-4A
           GotoAct, g3;
       Null & 0 = 0: GotoAct, g1;
     s2:
       SourceAdjacentAddress & FF-FF-FF-FF-FF-FF = 02-07-01-04-ED-4A:
           Goto, s3;
       Null & 0 = 0: NoMatch, 0;
     s3:
       DestAdjacentAddress & FF-FF-FF-FF-FF-FF = 00-80-48-81-0E-7C:
           NoMatch, 0;
       Null & 0 = 0: GotoAct, g2;
     #
     g1: FlowClass & 255 = 1:  PushtoAct, c_pkt;  # From g1
     g2: FlowClass & 255 = 2:  PushtoAct, c_pkt;  # From g2
     g3: FlowClass & 255 = 3:  PushtoAct, c_pkt;  # g1 to g2
     #
     c_pkt:
       SourceAdjacentAddress & FF-FF-FF-FF-FF-FF = 0:
           PushPkttoAct, Next;
       DestAdjacentAddress & FF-FF-FF-FF-FF-FF = 0: PushPkttoAct, Next;
       SourcePeerAddress & 255.255.255.255 = 0: PushPkttoAct, Next;
       DestPeerAddress & 255.255.255.255 = 0: PushPkttoAct, Next;
       Null & 0 = 0:  Count, 0

   The first two rules ignore non-IP packets.  The next two rules Goto
   s1 if the packet's source was g1, or to s2 otherwise.  The rule
   labelled s2 tests whether the packet's source was g2; if not a
   NoMatch action is executed, allowing the PME to try the match with
   the packet's direction reversed.  If the match fails on the second
   try the packet didn't come from (or go to) g1 or g2, and is ignored.





Brownlee                     Informational                     [Page 20]


RFC 2123                Traffic Flow Measurement              March 1997


   Packets which come from g1 are tested by the rule labelled s1, and
   the PME will Goto either g3 or g1.

   Packets which came from g2 are tested by the rule labelled s3.  If
   they are not going to g1 the PME will Goto g2.  If they are going to
   g1 a NoMatch action is executed - we want them counted as backward-
   travelling packets for the g1-g2 flow.

   The rules at g1, g2 and g3 push the value 1, 2 or 3 from their rule
   into the flow's FlowClass attribute.  This value can be used by an
   Analysis Application to separate the flows into the three groups of
   interest.  FlowClass is an example of a 'computed' attribute, i.e.
   one whose value is Pushed by the PME during rule matching.

   The remaining rules Push the values of other attributes required for
   later analysis, then Count the flow.

3.3 Subroutines

   Subroutines are implemented in the PME in much the same way as in
   BASIC.  A subroutine body is just a sequence of statements, supported
   by the GoSub and Return actions.  'GoSub' saves the PME's running
   environment and jumps to the first rule of the subroutine body.
   Subroutine calls may be nested as required - NeTraMet defines the
   maximum nesting at compile time.  'Return n' restores the environment
   and jumps to the action part of the nth rule after the Gosub, where n
   is the index value from the Return rule.

   The Return action provides a way of influencing the flow of control
   in a rule set, rather like a FORTRAN Computed Goto.  This is one way
   in which a subroutine can return a result.  The other way is by
   Pushing a value in either a computed attribute (as demonstrated in
   the preceding section), or in a flow attribute.

   One common use for a subroutine is to test whether a packet attribute
   matches one of a set of values.  Such a subroutine becomes much more
   useful if it can be used to test one of several attributes.  The PME
   architecture provides for this by using 'meter variables' to hold the
   names of the attributes to be tested.  The meter variables are called
   V1, V2, V3, V4 and V5, and the Assign action is provided to set their
   values.  If, for example, we need a subroutine to test either
   SourcePeerAddress or DestPeerAddress, we write its rules to test V1
   instead.  Before calling the subroutine we Assign SourcePeerAddress
   to V1; later tests of V1 are converted by the PME into tests on
   SourcePeerAddress.  Note that since meter variables may be reassigned
   in a subroutine, their values are part of the environment which must
   be saved by a Gosub action.




Brownlee                     Informational                     [Page 21]


RFC 2123                Traffic Flow Measurement              March 1997


   The following rule set demonstrates the use of a subroutine ..

     #  Rule specification file to tally IP packets in three groups:
     #     UA to AIT, UA to elsewhere, AIT to elsewhere
     #
     #     -------+-------------------+-----------------+--------
     #            |                   |                 |
     #       +----+-----+        +----+-----+        +---+---+
     #       |   UA     |        |   AIT    |        | meter |
     #       +-+-+-+-+--+        +-+-+-+-+--+        +-------+
     #
       SourcePeerType & 255 = IP:      PushtoAct, ip_pkt;
       Null & 0 = 0:                   Ignore, 0;
     #
     ip_pkt:
       v1 & 0 = SourcePeerAddress:  AssignAct, Next;
       Null & 0 = 0:  Gosub, classify;
         Null & 0 = 0:  GotoAct, from_ua;    # 1 ua
         Null & 0 = 0:  GotoAct, from_ait;   # 2 ait
         Null & 0 = 0:  NoMatch, 0;          # 3 other
     #
     from_ua:
       v1 & 0 = DestPeerAddress:  AssignAct, Next;
       Null & 0 = 0:  Gosub, classify;
         Null & 0 = 0:  Ignore, 0;            # 1 ua-ua
         Null & 0 = 0:  GotoAct, ok_pkt;      # 2 ua-ait
         Null & 0 = 0:  Gotoact, ok_pkt;      # 3 ua-other
     #
     from_ait:
       v1 & 0 = DestPeerAddress:  AssignAct, Next;
       Null & 0 = 0:  Gosub, classify;
         Null & 0 = 0:  NoMatch, 0;           # 1 ait-ua
         Null & 0 = 0:  Ignore, 0;            # 2 ait-ait
         Null & 0 = 0:  GotoAct, ok_pkt;      # 3 ait-other
     #
     ok_pkt:
       Null & 0 = 0:                   Count, 0;

   The subroutine begins at the rule labelled classify (shown below).
   It returns to the first, second or third rule after the invoking
   Gosub rule, depending on whether the tested PeerAddress is in the UA,
   AIT, or 'other' group of networks.  In the listing below only one
   network is tested in each of the groups - it is trivial to add more
   rules (one per network) into either of the first two groups.  In this
   example the subroutine Pushes the network number from the packet into
   the tested attribute before returning.





Brownlee                     Informational                     [Page 22]


RFC 2123                Traffic Flow Measurement              March 1997


   The first invocation of classify (above) begins at the rule labelled
   ip_pkt.  It Assigns SourcePeerAddress to V1 then executes a Gosub
   action.  Classify returns to one of the three following rules.  They
   will Goto from_ua or from_ait if the packet came from the UA or AIT
   groups, otherwise the PME will retry the match.  This means that
   matched flows will have a UA or AIT network as their source, and
   flows between other networks will be ignored.

   The next two invocations of 'classify' test the packet's
   DestPeerAddress.  Packets from AIT to UA are Retried, forcing them to
   be counted as AU to AIT flows.  Packets from UA to UA are ignored, as
   are packets from AIT to AIT.

     classify:
       v1 & 255.255.0.0 = 130.216.0.0:  GotoAct, ua;   # ua
       v1 & 255.255.0.0 = 156.62.0.0:   GotoAct, ait;  # ait
       Null & 0 = 0:                    Return, 3;     # other
     ua:
       v1 & 255.255.0.0 = 0:            PushPkttoAct, Next;
       Null & 0 = 0:                    Return, 1;
     ait:
       v1 & 255.255.0.0 = 0:            PushPkttoAct, Next;
       Null & 0 = 0:                    Return, 2;

3.4 More complicated rule sets

   The next example demonstrates a way of grouping IP flows together
   depending on their Transport Address, i.e. their IP port number.
   Simply Pushing every flow's SourceTransAddress and DestTransAddress
   would produce a large number of flows, most of which differ only in
   one of their transport addresses (the one which is not a well-known
   port).

   Instead we Push the well-known port number into each flow's
   SourceTransAddress; its DestTransAddress will be zero by default.

     SourcePeerType & 255 = dummy:      Ignore, 0;
     SourcePeerType & 255 = IP:         Pushto, IP_pkt;
     Null & 0 = 0:   GotoAct, Next;
     SourcePeerType & 255 = 0:      PushPkttoAct, Next;
     Null & 0 = 0:  Count, 0;  # Count others by protocol type
  #
  IP_pkt:
    SourceTransType & 255 = tcp:    Pushto, tcp_udp;
    SourceTransType & 255 = udp:    Pushto, tcp_udp;
    SourceTransType & 255 = icmp:   CountPkt, 0;
    SourceTransType & 255 = ospf:   CountPkt, 0;
    Null & 0 = 0:  GotoAct, c_unknown;  #  Unknown transport type



Brownlee                     Informational                     [Page 23]


RFC 2123                Traffic Flow Measurement              March 1997


  #
  tcp_udp:
  s_domain:
    SourceTransAddress & 255.255 = domain:  PushtoAct, c_well_known;
  s_ftp:
    SourceTransAddress & 255.255 = ftp:     PushtoAct, c_well_known;
  s_imap:
    SourceTransAddress & 255.255 = 113:     PushtoAct, c_well_known;
  s_nfs
    SourceTransAddress & 255.255 = 2049:    PushtoAct, c_well_known;
  s_pop:
    SourceTransAddress & 255.255 = 110:     PushtoAct, c_well_known;
  s_smtp:
    SourceTransAddress & 255.255 = smtp:    PushtoAct, c_well_known;
  s_telnet:
    SourceTransAddress & 255.255 = telnet:  PushtoAct, c_well_known;
  s_www:
    SourceTransAddress & 255.255 = www:     PushtoAct, c_well_known;
  s_xwin
    SourceTransAddress & 255.255 = 6000:    PushtoAct, c_well_known;
  #
    DestTransAddress & 255.255 = domain:    GotoAct, s_domain;
    DestTransAddress & 255.255 = ftp:       GotoAct, s_ftp;
    DestTransAddress & 255.255 = 113:       GotoAct, s_imap;
    DestTransAddress & 255.255 = 2049:      GotoAct, s_nfs;
    DestTransAddress & 255.255 = 110:       GotoAct, s_pop;
    DestTransAddress & 255.255 = smtp:      GotoAct, s_smtp;
    DestTransAddress & 255.255 = telnet:    GotoAct, s_telnet;
    DestTransAddress & 255.255 = www:       GotoAct, s_www;
    DestTransAddress & 255.255 = 6000:      GotoAct, s_xwin;
  #
    Null & 0 = 0:  GotoAct, c_unknown;  #  'Unusual' port
  #
  c_unknown:
    SourceTransType    & 255 = 0:     PushPkttoAct, Next;
    DestTransType      & 255 = 0:     PushPkttoAct, Next;
    SourceTransAddress & 255.255 = 0: PushPkttoAct, Next;
    DestTransAddress   & 255.255 = 0: CountPkt, 0;
  #
  c_well_known:
    Null & 0 = 0:  Count, 0
  #

   The first few rules ignore dummy packets, select IP packets for
   further processing, and count packets for other protocols in a single
   flow for each PeerType.  TCP and UDP packets cause the PME to Push
   their TransType and Goto tcp_udp.  ICMP and OSPF packets are counted
   in flows which have only their TransType Pushed.



Brownlee                     Informational                     [Page 24]


RFC 2123                Traffic Flow Measurement              March 1997


   At tcp_udp the packets' SourceTransAddress is tested to see whether
   it is included in a set of 'interesting' port numbers.  If it is, the
   port number is pushed from the rule into the SourceTransAddress
   attribute, and the packet is counted at c_well_known.  (NeMaC accepts
   Pushto as a synonym for PushRuleto).

   This testing is repeated for the packet's DestTransAddress; if one of
   these tests succeeds the PME Goes to the corresponding rule above and
   Pushes the port number into the flow's SourceTransAddress.  If these
   tests fail the packet is counted at c_unknown, where all the flow's
   Trans attributes are pushed.  For production use more well-known
   ports would need to be included in the tests above - c_unknown is
   intended only for little-used exception flows!

   Note that these rules only Push a value into a flow's
   SourceTransAddress, and they don't contain any NoMatch actions.  They
   therefore don't specify a packet's direction, and they could be used
   in other rule sets to group together flows for well-known ports.

   The last example (below) meters flows from a remote router, and
   demonstrates another approach to grouping well-known ports.

    SourceAdjacentAddress & FF-FF-FF-FF-FF-FF =
        00-60-3E-10-E0-A1:  Goto, gateway;  # tmkr2 router
    DestAdjacentAddress & FF-FF-FF-FF-FF-FF = 00-60-3E-10-E0-A1:
        Goto, gateway;  # Source is tmkr2
    Null & 0 = 0:  Ignore, 0;
  #
  gateway:
    SourcePeerType & 255 = IP:  GotoAct, IP_pkt;
    Null & 0 = 0:  GotoAct, Next;
    SourcePeerType & 255 = 0:  CountPkt, 0;
  #
  IP_pkt:
    SourceTransType & 255 = tcp:    PushRuleto, tcp_udp;
    SourceTransType & 255 = udp:    PushRuleto, tcp_udp;
    Null & 0 = 0:  GotoAct, not_wkp;  #  Unknown transport type
  #
  tcp_udp:
    SourceTransAddress & FC-00 = 0:  GotoAct, well_known_port;
    DestTransAddress & FC-00 = 0:  NoMatch, 0;
    Null & 0 = 0:  GotoAct, not_wkp;
  #
  not_wkp:
    DestTransAddress   & 255.255       = 0: PushPkttoAct, Next;
  well_known_port:
    SourcePeerType     & 255           = 0: PushPkttoAct, Next;
    DestPeerType       & 255           = 0: PushPkttoAct, Next;



Brownlee                     Informational                     [Page 25]


RFC 2123                Traffic Flow Measurement              March 1997


    SourcePeerAddress  & 255.255.255.0 = 0: PushPkttoAct, Next;
    DestPeerAddress    & 255.255.255.0 = 0: PushPkttoAct, Next;
    SourceTransType    & 255           = 0: PushPkttoAct, Next;
    DestTransType      & 255           = 0: PushPkttoAct, Next;
    SourceTransAddress & 255.255       = 0: CountPkt, 0;

   The first group of rules test incoming packet's AdjacentAddresses to
   see whether they belong to a flow with an end point at the specified
   router.  Any which don't are ignored.  Non-IP packets are counted in
   flows which only have their PeerType Pushed; these will produce one
   flow for each non-IP protocol.  IP packets with TransTypes other than
   UDP and TCP are counted at not_wkp, where all their address
   attributes are pushed.

   The high-order six bits of SourceTransAddress for UDP and TCP packets
   are compared with zero.  If this succeeds their source port number is
   less than 1024, so they are from a well-known port.  The port number
   is pushed from the rule into the flow's SourceTransAddress attribute,
   and the packet is counted at well_known_port.  If the test fails, it
   is repeated on the packet's DestTransAddress.  If the destination is
   a well-known port the match is Retried, and will succeed with the
   well-known port as the flow's source.

   If later analysis were to show that a high proportion of the observed
   flows were from non-well-known ports, further pairs of rules could be
   added to perform a test in each direction for other heavily-used
   ports.

4 Flow data files

   Although the Architecture document [1] specifies - in great detail -
   how the Traffic Flow Meter works, and how a meter reader should
   collect flow data from a meter, it does not say anything about how
   the collected data should be stored.  NeMaC uses a simple, self-
   documenting file format, which has proved to be very effective in
   use.

   There are two kinds of records in a flow data file:  flow records and
   information records.  Each flow record is simply a sequence of
   attribute values with separators (these can be specified in a NeMaC
   rule file) or spaces between them, terminated by a newline.

   Information records all start with a cross-hatch.  The file's first
   record begins with ##, and identifies the file as being a file of
   data from NeTraMet.  It records NeMaC's parameters and the time this
   collection was started.  The file's second record begins with
   #Format: and is a copy of the Format statement used by NeMaC to
   collect the data.



Brownlee                     Informational                     [Page 26]


RFC 2123                Traffic Flow Measurement              March 1997


   The rest of the file is a sequence of collected data sets.  Each of
   these starts with a #Time:  record, giving the time-of-day the
   collection was started, the meter name, and the range of meter times
   this collection represents.  These from and to times are meter
   UpTimes, i.e. they are times in hundredths of seconds since the meter
   commenced operation.  Most analysis applications have simply used the
   collection start times (which are ASCII time-of-day values), but the
   from and to times could be used to convert Uptime values to time-of-
   day.  The flow records which comprise a data set follow the #Time
   record.

4.1 Sample flow data file

   A sample flow data file appears below.  Most of the flow records have
   been deleted, but lines of dots show where they were.

  ##NeTraMet v3.2.  -c300 -r rules.lan -e rules.default
    test_meter -i eth0  4000 flows  starting at 12:31:27 Wed 1 Feb 95
  #Format: flowruleset flowindex firsttime  sourcepeertype
    sourcepeeraddress destpeeraddress  topdus frompdus
    tooctets fromoctets
  #Time: 12:31:27 Wed  1 Feb 95 130.216.14.251 Flows
    from 1 to 3642
  1 2 13  5 31.32.0.0 33.34.0.0  1138 0  121824 0
  1 3 13  2 11.12.0.0 13.14.0.0  4215 0  689711 0
  1 4 13  7 41.42.0.0 43.34.0.0  1432 0  411712 0
  1 5 13  6 21.22.0.0 23.24.0.0  8243 0  4338744 0
  3 6 3560  2 130.216.14.0 130.216.3.0  0 10  0 1053
  3 7 3560  2 130.216.14.0 130.216.76.0  59 65  4286 3796
  3 8 3560  7 0.0.255.0 1.144.200.0  0 4  0 222
  3 9 3560  2 130.216.14.0 130.216.14.0  118 1  32060 60
  3 10 3560  6 130.216.0.28 130.216.0.192  782 1  344620 66
  3 11 3560  7 0.0.255.0 0.128.113.0  0 1  0 73
  3 12 3560  5 59.3.13.0 4.1.152.0  1 1  60 60
  3 13 3560  7 0.128.94.0 0.129.27.0  2 2  120 158
  3 14 3560  5 59.3.40.0 4.1.153.0  2 2  120 120
  3 15 3560  5 0.0.0.0 4.1.153.0  0 1  0 60
  3 16 3560  5 4.1.152.0 59.2.189.0  2 2  120 120
       .  .  .  .  .  .  .  .  .
  3 42 3560  7 0.128.42.0 0.129.34.0  0 1  0 60
  3 43 3560  7 0.128.42.0 0.128.43.0  0 1  0 60
  3 44 3560  7 0.128.42.0 0.128.41.0  0 1  0 60
  3 45 3560  7 0.128.42.0 0.129.2.0  0 1  0 60
  3 46 3560  5 4.1.152.0 59.2.208.0  2 2  120 120
  3 47 3560  5 59.3.46.0 4.1.150.0  2 2  120 120
  3 48 3560  5 4.1.152.0 59.2.198.0  2 2  120 120
  3 49 3560  5 0.0.0.0 59.2.120.0  0 1  0 60
  3 50 3664  5 4.1.152.0 59.2.214.0  0 1  0 60



Brownlee                     Informational                     [Page 27]


RFC 2123                Traffic Flow Measurement              March 1997


  3 51 3664  5 0.0.0.0 4.2.142.0  0 1  0 60
  3 52 3664  5 4.1.153.0 59.3.45.0  4 4  240 240
  #Time: 12:36:25 Wed  1 Feb 95 130.216.14.251 Flows
    from 3641 to 33420
  3 6 3560  2 130.216.14.0 130.216.3.0  0 21  0 2378
  3 7 3560  2 130.216.14.0 130.216.76.0  9586 7148  1111118 565274
  3 8 3560  7 0.0.255.0 1.144.200.0  0 26  0 1983
  3 9 3560  2 130.216.14.0 130.216.14.0  10596 1  2792846 60
  3 10 3560  6 130.216.0.28 130.216.0.192  16589 1  7878902 66
  3 11 3560  7 0.0.255.0 0.128.113.0  0 87  0 16848
  3 12 3560  5 59.3.13.0 4.1.152.0  20 20  1200 1200
  3 13 3560  7 0.128.94.0 0.129.27.0  15 14  900 1144
  3 14 3560  5 59.3.40.0 4.1.153.0  38 38  2280 2280
  3 15 3560  5 0.0.0.0 4.1.153.0  0 30  0 1800
  3 16 3560  5 4.1.152.0 59.2.189.0  20 20  1200 1200
  3 17 3560  5 0.0.0.0 59.2.141.0  0 11  0 660
      .  .  .  .  .  .  .  .  .
  3 476 26162  7 0.129.113.0 0.128.37.0  0 1  0 82
  3 477 27628  7 0.128.41.0 0.128.46.0  1 1  543 543
  3 478 27732  7 0.128.211.0 0.128.46.0  1 1  543 543
  3 479 31048  7 0.128.47.0 2.38.221.0  1 1  60 60
  3 480 32717  2 202.14.100.0 130.216.76.0  0 4  0 240
  3 481 32717  2 130.216.76.0 130.216.3.0  0 232  0 16240
  #Time: 12:41:25 Wed  1 Feb 95 130.216.14.251 Flows
    from 33419 to 63384
  3 6 3560  2 130.216.14.0 130.216.3.0  51 180  3079 138195
  3 7 3560  2 130.216.14.0 130.216.76.0  21842 18428  2467693 1356570
  3 8 3560  7 0.0.255.0 1.144.200.0  0 30  0 2282
  3 9 3560  2 130.216.14.0 130.216.14.0  24980 1  5051834 60
  3 10 3560  6 130.216.0.28 130.216.0.192  20087 1  8800070 66
  3 11 3560  7 0.0.255.0 0.128.113.0  0 164  0 32608
  3 12 3560  5 59.3.13.0 4.1.152.0  41 41  2460 2460
  3 14 3560  5 59.3.40.0 4.1.153.0  82 82  4920 4920
  3 15 3560  5 0.0.0.0 4.1.153.0  0 60  0 3600
      .  .  .  .  .  .  .  .  .

4.2 Flow data file features

   Several features of NeMaC's flow data files (as indicated above) are
   worthy of note:

  - Collection times overlap slightly between samples.  This allows for
    flows which were created after the collection started, and makes
    sure that flows are not missed from a collection.







Brownlee                     Informational                     [Page 28]


RFC 2123                Traffic Flow Measurement              March 1997


  - The rule set may change during a run.  The above shows flows from
    rule set 1 - the default set - in the first collection, followed by
    the first flows created by rule set 3 (which has just been
    downloaded by NeMaC).

  - FlowIndexes may be reused by the meter once their flows have been
    recovered by the garbage collector.  The combination of
    FlowRuleSet, FlowIndex and StartTime are needed to identify a flow
    uniquely.

  - Packet and Byte counters are 32-bit unsigned integers, and are
    never reset by the meter.  Computing the counts occurring within a
    collection interval requires taking the difference between the
    collected count and its value when the flow was last collected.
    Note that counter wrap-around can be allowed for by simply
    performing an unsigned subtraction and ignoring any carry.

  - In the sample flow data file above I have used double spaces as
    separators between the flow identifiers, peer addresses, pdu counts
    and packet counts.

  - The format of addresses in the flow data file depends on the type
    of address.  NeMaC always displays Adjacent addresses as six hex
    bytes separated by hyphens, and Transport addresses as (16-bit)
    integers.  The format of a Peer address depends on its PeerType,
    e.g. dotted decimal for IP. To facilitate this NeMaC needs to know
    the PeerType for each flow; the user must request NeMaC to collect
    it.

4.3 Terminating and restarting meter reading

   When NeMaC first starts collecting from a meter, it reads the flow
   data for all active flows.  This provides a starting point for
   analysis applications to compute the counts between successive
   collections.

   From time to time the user needs to terminate a flow data file and
   begin a new one.  For example, a user might need to generate a
   separate file for each day of metering.  NeMaC provides for this by
   closing the file after each collection, then opening it and appending
   the data from the next collection.  To terminate a file the user
   simply renames it.  The Unix system will effect the name change
   either immediately (if the file was closed) or as soon as the current
   collection is complete (and the file is closed).

   When NeMaC begins its next collection it observes that the file has
   disappeared, so it creates a new one and writes the # header records
   before writing the collected data.



Brownlee                     Informational                     [Page 29]


RFC 2123                Traffic Flow Measurement              March 1997


   There is one aspect of the above which requires some care on the
   user's part.  The last data set in a file is not duplicated as the
   first data set of the next file.  In other words, analysis
   applications must either look ahead at the first data set of the next
   file, or begin by reading the last data set of the previous file.  If
   they fail to do this they will loose one collection's worth of flow
   data at each change of file.

5 Analysis applications

   Most analysis applications will be unique, taking data produced by a
   locally-developed rule set and producing reports to satisfy specific
   local requirements.  The NeTraMet distribution files include three
   applications which are of general use, as follows:

  - fd_filter computes data rates, i.e. the differences between
    successive data sets in a flow data file.  It also allows the user
    to assign a 'tag' number to each flow; these are 'computed'
    attributes similar to FlowClass and FlowKind - the only difference
    is that they are computed from the collected data sets.

  - fd_extract takes 'tagged' files from fd_filter and produces simple
    'column list' files for use by other programs.  One common use for
    fd_extract is to produce time-series data files which can be plotted
    by utilities like GNUPlot.

  - nm_rc is a 'remote console' for a NeTraMet meter.  It is a slightly
    simplified version of NeMaC combined with fd_filter.  It can be used
    to monitor any meter, and will display (as lines of text
    characters) information about the n busiest flows observed during
    each collection interval.

  - nifty is a traffic flow analyser, which (like nm_rc) displays data
    from a NeTraMet meter.  nifty is an X/Motif application, which
    produces displays like 'Packet rate (pps) vs Flow lifetime
    (minutes),' so as to highlight those flows which are 'interesting.'

   These applications are useful in themselves, and they provide a good
   starting point for users who wish to write their own analysis
   applications.











Brownlee                     Informational                     [Page 30]


RFC 2123                Traffic Flow Measurement              March 1997


6 Using NeTraMet in a measurement system

   This section gives a brief summary of the steps involved in setting
   up a traffic measurement system using NeTraMet.  These are:

  - Decide what is to be measured.  One good way to approach this is to
    specify exactly which flows are to be measured, and what reports
    will be required.  Specifying the flows should make it obvious
    where meters will have to be placed so that the flows can be
    observed, whether PCs will be adequate for the task, etc..

  - Install meters.  As well as actually placing the meter hosts this
    includes making sure that they are configured correctly, with
    appropriate IP addresses, SNMP community strings, etc.

  - Develop the rule set (and a standby rule set).  The degree of
    difficulty here depends on how much is known in advance about the
    traffic.  One possible approach is to start with the meter default
    rule set and measure how much traffic there is for each PeerType.
    (This is a good way to verify that NeTraMet and NeMaC are working
    properly).  You can now add rules so as to increase the granularity
    of the flows; this will of course increase the number of flows to
    be collected, and force the meter's garbage collector to work
    harder.  Another approach is to try a rule set with very fine
    granularity (i.e. one which Pushes all the address attributes),
    then observing how many flows are collected every few minutes.

  - Develop a strategy for controlling meter reader.  This means
    setting the meter's maximum number of flows, the collection
    interval, how breaks between flow data files will be handled, how
    often NeMaC should check that the meter is running, etc.

  - Develop application(s) to process the collected flow data and
    produce the required files and reports.

  - Test run.  Monitor the system, then refine the rule sets and meter
    reading strategy until the overall system performance is
    satisfactory.

   This process can take quite a long time, but the overall result is
   well worth the effort.

6.1 Examples of NeTraMet in production use

   At the University of Auckland we run two sets of meters.  One of
   these measures the traffic entering and leaving our University
   network, and generates usage reports for all our Internet users.
   This has been in production since early 1994.



Brownlee                     Informational                     [Page 31]


RFC 2123                Traffic Flow Measurement              March 1997


   The other set consists of meters which are distributed at
   Universities throughout New Zealand.  They provide continuous traffic
   flow measurements at five-minute intervals for all the links making
   up the Universities' network (Kawaihiko); this system has been in
   production since January 1996, and has already proved very useful in
   planning the network's development.

   The Kawaihiko Network provides IP connectivity for the New Zealand
   Universities.  They are linked via a Frame Relay cloud, using a
   partial mesh of permanent virtual circuits.  There is a NeTraMet
   meter at each site, metering inward and outward traffic.  All the
   meters are managed from Auckland, and they all run copies of the same
   rule set.

   The rule set has about 650 rules, most of which are in a single
   subroutine which classifies PeerAddresses into three categories -
   'Kawaihiko network,' 'other New Zealand network' and 'non-New Zealand
   network.'  Inside New Zealand IP addresses lie within six CIDR
   blocks, and there are about four hundred older networks which have
   addresses outside those blocks.  The rules are arranged in groups by
   subnet size, i.e. all the /24 networks are tested first, then the /23
   networks, etc, finishing with the /16 networks.  This means that
   although there are about 600 networks, any PeerAddress can be
   classified with only nine tests.

   The Kawaihiko rule set classifies flows, using computed attributes to
   indicate the network 'kind' (Kawaihiko / New Zealand / international)
   for each flow's SourcePeerAddress and DestPeerAddress, and to
   indicate whether the flow is a 'network news' flow or not.

   Flow data is collected from all of the meters every five minutes, and
   is used to produce weekly reports, as follows:

  - Traffic Plots.  Plots of the 5-minute traffic rates for each site,
    showing international traffic in and out, news traffic in and out,
    and total traffic in and out of the site.

  - Traffic Matrices.  Two of these are produced, one for news traffic,
    the other for total traffic.  They show the traffic rates from
    every site (including 'other New Zealand' and 'international') to
    every other site.  The mean, third quartile and maximum are printed
    for every cell in the matrices.









Brownlee                     Informational                     [Page 32]


RFC 2123                Traffic Flow Measurement              March 1997


7 Acknowledgments

   This memo documents the implementation work on traffic flow
   measurement here at the University of Auckland.  Many of my
   University colleagues have contributed significantly to this work,
   especially Russell Fulton (who developed the rules sets, Perl scripts
   and Cron jobs which produce our traffic usage reports automatically
   week after week) and John White (for his patient help in documenting
   the project).

8 References

    [1] Brownlee, N., Mills, C., and G. Ruth, "Traffic Flow
    Measurement: Architecture", RFC 2063, The University of Auckland,
    Bolt Beranek and Newman Inc., GTE Laboratories, Inc, January 1997.

    [2] Brownlee, N., "Traffic Flow Measurement:  Meter MIB",
    RFC 2064, The University of Auckland, January 1997.

    [3] CRYNWR Packer Drivers distribution site:
    http://www.crynwr.com/

    [4] Case J., McCloghrie K., Rose M., and Waldbusser S.,
    "Structure of Management Information for version 2 of the
    Simple Network Managemenet Protocol", RFC 1902, SNMP Research
    Inc., Hughes LAN Systems, Dover Beach Consulting, Carnegie
    Mellon University, April 1993.

    [5] IBM Corporation, "IBM PC Technical Reference Manual," 1984.

    [6] Waterloo TCP distribution site:
    http://mvmpc9.ciw.uni-karlsruhe.de:80/d:/public/tcp_ip/wattcp

    [7] CMU SNMP distribution site:
    ftp://lancaster.andrew.cmu.edu/pub/snmp-dist

    [8] libpcap distribution site:
    ftp://ftp.ee.lbl.gov/libpcap-*.tar.gz













Brownlee                     Informational                     [Page 33]


RFC 2123                Traffic Flow Measurement              March 1997


9 Security Considerations

   Security issues are not discussed in detail in this document.  The
   meter's management and collection protocols are responsible for
   providing sufficient data integrity and confidentiality.

10 Author's Address

   Nevil Brownlee
   The University of Auckland

   Phone: +64 9 373 7599 x8941
   Email: n.brownlee@auckland.ac.nz






































Brownlee                     Informational                     [Page 34]