Network Working Group K. S. Teow Request for Comments: 2837 Brocade Communications Systems, Inc. Category: Standards Track May 2000 Definitions of Managed Objects for the Fabric Element in Fibre Channel Standard Status of this Memo This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited. Copyright Notice Copyright (C) The Internet Society (2000). All Rights Reserved. Abstract This memo defines an extension to the Management Information Base (MIB) for use with network management protocols in TCP/IP-based internets. In particular, it defines the objects for managing the operations of the Fabric Element portion of the Fibre Channel Standards. Table of Contents 1. The SNMP Management Framework ..................................2 2. Overview .......................................................3 2.1 Management View of a Fabric Element ...........................4 2.2 Structure of the Fabric Element MIB ...........................5 3. Object Definitions .............................................6 The Configuration Group ......................................8 The Module Table ...........................................9 The FxPort Configuration Table ............................12 The Status Group ............................................16 The FxPort Status Table ...................................16 The FxPort Physical Level Table ...........................18 The FxPort Fabric Login Table .............................20 The Error Group .............................................24 The Accounting Groups........................................27 The Class 1 Accounting Table ..............................27 The Class 2 Accounting Table ..............................31 The Class 3 Accounting Table ..............................33 The Capability Group ........................................35 Teow Standards Track [Page 1]
RFC 2837 FC Fabric Element MIB May 2000 Conformance information .....................................38 4. Security Considerations .......................................43 5. Intellectual Property .........................................44 6. Acknowledgements ..............................................44 7. References ....................................................45 7.1 IETF References ..............................................45 7.2 Approved ANSI/NCITS References ...............................46 7.3 ANSI/NCITS References Under Development ......................47 8. Editors' Addresses ............................................47 9. Full Copyright Statement ......................................48 1. The SNMP Management Framework The SNMP Management Framework presently consists of five major components: o An overall architecture, described in RFC 2571 [1]. o Mechanisms for describing and naming objects and events for the purpose of management. The first version of this Structure of Management Information (SMI) is called SMIv1 and described in STD 16, RFC 1155 [2], STD 16, RFC 1212 [3] and RFC 1215 [4]. The second version, called SMIv2, is described in STD 58, RFC 2578 [5], STD 58, RFC 2579 [6] and STD 58, RFC 2580 [7]. o Message protocols for transferring management information. The first version of the SNMP message protocol is called SNMPv1 and described in STD 15, RFC 1157 [8]. A second version of the SNMP message protocol, which is not an Internet standards track protocol, is called SNMPv2c and described in RFC 1901 [9] and RFC 1906 [10]. The third version of the message protocol is called SNMPv3 and described in RFC 1906 [10], RFC 2572 [11] and RFC 2574 [12]. o Protocol operations for accessing management information. The first set of protocol operations and associated PDU formats is described in STD 15, RFC 1157 [8]. A second set of protocol operations and associated PDU formats is described in RFC 1905 [13]. o A set of fundamental applications described in RFC 2573 [14] and the view-based access control mechanism described in RFC 2575 [15]. A more detailed introduction to the current SNMP Management Framework can be found in RFC 2570 [16]. Teow Standards Track [Page 2]
RFC 2837 FC Fabric Element MIB May 2000 Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. Objects in the MIB are defined using the mechanisms defined in the SMI. This memo specifies a MIB module that is compliant to the SMIv2. A MIB conforming to the SMIv1 can be produced through the appropriate translations. The resulting translated MIB must be semantically equivalent, except where objects or events are omitted because no translation is possible (use of Counter64). Some machine readable information in SMIv2 will be converted into textual descriptions in SMIv1 during the translation process. However, this loss of machine readable information is not considered to change the semantics of the MIB. 2. Overview A Fibre Channel Fabric is an entity which interconnects Node Ports (N_Ports) or Node Loop Ports (NL_Ports). It provides transport and routing functions. In essence, a Fabric is a network of N_Ports and/or NL_Ports to communicate with one another. A Fabric is composed of one or more Fabric Element that are interconnected via Inter-element Links (IEL). A Fabric Element is the smallest unit of a Fabric that meets the definition of a Fabric. It must consist of at least three external ports to connect to either N_Ports, NL_Ports or other Fabric Elements. In general, a Fabric Element port may be of one of the following types: (1) F_Port, a fabric port to connect to an N_Port ([17], [21], [22]); (2) FL_Port, a fabric port that also supports a FC Arbitrated Loop consisting of one or more NL_Ports ([20], [24]). (3) E_Port, an expansion port to connect to another Fabric Element ([18], [23]); This memo shall define objects related to a Fabric Element, its F_Ports and FL_Ports. Objects related to other types of FC ports shall be defined in future. For the rest of the document, the term, "FxPort", will be used to refer to both F_Port and FL_Port where the distinction is not necessary. The term, "NxPort" will be used to refer to both N_Port and NL_Port in the similar fashion. Teow Standards Track [Page 3]
RFC 2837 FC Fabric Element MIB May 2000 2.1. Management View of a Fabric Element From the management perspective, it is helpful to view a Fabric Element to be consisting of multiple "modules". Each module is a grouping, either physical or logical, of one or more ports that may be managed as a sub-entity within the Fabric Element. This module mapping is recommended but optional. A vendor may elect to put all ports into a single module, or to divide the ports into modules that do not match physical divisions. The object fcFeModuleCapacity indicates the maximum number of modules that a given Fabric Element may contain. This value must remain constant from one management restart to the next. Each module is uniquely identified by a module number in the range of 1 through fcFeModuleCapacity inclusive. Modules may come and go without causing a management reset (of sysUpTime), and may be sparsely numbered within the Fabric Element. That is, the module numbering is not required to be contiguous. For instance, if a module is mapped physically to a field-replaceable card and in a 13- card cage Fabric Element, cards 3, 5, 6 and 7 may be installed. The vendor may choose to label them as modules 3, 5, 6 and 7 respectively. In this example, the value of fcFeModuleCapacity is 13. Note that the object fcFeModuleLastChange acts as the discontinuity indicator for all counter objects in this MIB. A Fabric Element may also provide a proxy management on behalf of another management entity by presenting it as one of its Fabric Element modules. The object fcFeModuleFxPortCapacity indicates the maximum number of ports that a given module may contain. The value of fcFeModuleFxPortCapacity must not change for a given module. However, a module may be deleted from the Fabric Element and replaced with a module containing a different number of ports. The value of fcFeModuleLastChange will indicate that a change took place. Each port within the Fabric Element is uniquely identified by a combination of module index and port index, where port index is an integer in the range (1..fcFeModuleFxPortCapacity). As with modules within a Fabric Element, ports within a module may be sparsely numbered. That is the port numbering is not required to be contiguous. Likewise, ports may come and go within a module without causing a management reset. Teow Standards Track [Page 4]
RFC 2837 FC Fabric Element MIB May 2000 In terms of attachment, an F_Port will be attached to another N_Port; and an FL_Port will be attached to one or up to 126 NL_Ports. In general, an FxPort may be attached to one or more NxPorts. Each NxPort associated with an FxPort will be uniquely identified by a combination of module index, FxPort index and NxPort index. An NxPort index is an integer in the range (1..126). The following diagram illustrates the management view of a Fabric Element. #=======================================================# # +----------------- - - - -----------------+ # # | Module 1 [1] . . . [i] | # # +----------------- - - - -----------------+ # # o o o # # +---------------------- - - - --------+ # # | Module M [1] . . . [n] | # # +---------------------- - - - -----^--+ # #=====================================|=================# | One or more NxPorts { [1] . . . [L] }<-+ - - - - - - - - - where "i", "n", "M" and "L" are some arbitrary sample integer values, and "L" must be less than 127. 2.2. Structure of the Fabric Element MIB This memo assumes that a Fabric Element has an SNMP entity associated with its managed objects. The managed objects are divided as follow: - the Configuration group - the Status group - the Error group - the Accounting group - the Capability group In each group, scalar objects and table entries are defined. The Configuration group contains configuration and service parameters for the Fabric Element, modules and the FxPorts. The Operation group contains the operational status and parameters of an FxPort. The group also contains the service parameters that have been established between the FxPort and its attached NxPort, if applicable. The Error group contains counters tracking various types of errors detected by each FxPort. The information may be used for diagnostics and/or to derive the quality of the link between an FxPort and one or more attached NxPorts. Teow Standards Track [Page 5]
RFC 2837 FC Fabric Element MIB May 2000 The Accounting group contains statistic data suitable for deriving accounting and performance information. The Capability group contains parameters indicating the inherent capability of the Fabric Element and each FxPort. 3. Object Definitions FIBRE-CHANNEL-FE-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Counter32, Gauge32, Integer32, mib-2 FROM SNMPv2-SMI TEXTUAL-CONVENTION, TruthValue, TimeStamp FROM SNMPv2-TC SnmpAdminString FROM SNMP-FRAMEWORK-MIB -- rfc2571 MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF; fcFeMIB MODULE-IDENTITY LAST-UPDATED "200005180000Z" ORGANIZATION "IETF IPFC Working Group" CONTACT-INFO "Kha Sin Teow Brocade Communications Systems, 1901 Guadalupe Parkway, San Jose, CA 95131 U.S.A Tel: +1 408 487 8180 Fax: +1 408 487 8190 Email: khasin@Brocade.COM WG Mailing list:ipfc@standards.gadzoox.com To Subscribe: ipfc-request@standards.gadzoox.com In Body: subscribe" DESCRIPTION "The MIB module for Fibre Channel Fabric Element." REVISION "200005180000Z" DESCRIPTION "Initial revision, published as RFC 2837." ::= { mib-2 75 } fcFeMIBObjects OBJECT IDENTIFIER ::= { fcFeMIB 1 } -- Note: -- fcFeMIBConformance OBJECT IDENTIFIER ::= { fcFeMIB 2 } -- see at the end of the module -- Groups under fcFeMIBObjects Teow Standards Track [Page 6]
RFC 2837 FC Fabric Element MIB May 2000 fcFeConfig OBJECT IDENTIFIER ::= { fcFeMIBObjects 1 } fcFeStatus OBJECT IDENTIFIER ::= { fcFeMIBObjects 2 } fcFeError OBJECT IDENTIFIER ::= { fcFeMIBObjects 3 } fcFeAccounting OBJECT IDENTIFIER ::= { fcFeMIBObjects 4 } fcFeCapabilities OBJECT IDENTIFIER ::= { fcFeMIBObjects 5 } -- Textual Conventions MilliSeconds ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents time unit value in milliseconds." SYNTAX Unsigned32 MicroSeconds ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents time unit value in microseconds." SYNTAX Unsigned32 FcNameId ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the Worldwide Name associated with a Fibre Channel (FC) entity." SYNTAX OCTET STRING (SIZE (8)) FcAddressId ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents Fibre Channel Address ID, a 24-bit value unique within the address space of a Fabric." SYNTAX OCTET STRING (SIZE (3)) FcRxDataFieldSize ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the receive data field size of an NxPort or FxPort." SYNTAX Integer32 (128..2112) FcBbCredit ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the buffer-to-buffer credit of an NxPort or FxPort." SYNTAX Integer32 (0..32767) FcphVersion ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the version of FC-PH supported by an NxPort or FxPort." SYNTAX Integer32 (0..255) FcStackedConnMode ::= TEXTUAL-CONVENTION Teow Standards Track [Page 7]
RFC 2837 FC Fabric Element MIB May 2000 STATUS current DESCRIPTION "Represents an enumerated value used to indicate the Class 1 Stacked Connect Mode supported by an NxPort or FxPort." SYNTAX INTEGER { none(1), transparent(2), lockedDown(3) } FcCosCap ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the class of service capability of an NxPort or FxPort." SYNTAX BITS { classF(0), class1(1), class2(2), class3(3), class4(4), class5(5), class6(6) } FcFeModuleCapacity ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the maximum number of modules within a Fabric Element." SYNTAX Unsigned32 FcFeFxPortCapacity ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the maximum number of FxPorts within a module." SYNTAX Unsigned32 FcFeModuleIndex ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the module index within a conceptual table." SYNTAX Unsigned32 FcFeFxPortIndex ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the FxPort index within a conceptual table." SYNTAX Unsigned32 FcFeNxPortIndex ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the NxPort index within a conceptual table." SYNTAX Integer32 (1..126) FcBbCreditModel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the BB_Credit model of an FxPort." SYNTAX INTEGER { regular(1), alternate (2) } Teow Standards Track [Page 8]
RFC 2837 FC Fabric Element MIB May 2000 -- The Configuration group -- This group consists of scalar objects and tables. -- It contains the configuration and service parameters -- of the Fabric Element and the FxPorts. -- The group represents a set of parameters associated with -- the Fabric Element or an FxPort to support its NxPorts. fcFeFabricName OBJECT-TYPE SYNTAX FcNameId MAX-ACCESS read-write STATUS current DESCRIPTION "The Name_Identifier of the Fabric to which this Fabric Element belongs." ::= { fcFeConfig 1 } fcFeElementName OBJECT-TYPE SYNTAX FcNameId MAX-ACCESS read-write STATUS current DESCRIPTION "The Name_Identifier of the Fabric Element." ::= { fcFeConfig 2 } fcFeModuleCapacity OBJECT-TYPE SYNTAX FcFeModuleCapacity MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of modules in the Fabric Element, regardless of their current state." ::= { fcFeConfig 3 } -- The Module Table. -- This table contains one entry for each module, -- information of the modules. fcFeModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFeModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each module in the Fabric Element, information of the modules." ::= { fcFeConfig 4 } fcFeModuleEntry OBJECT-TYPE Teow Standards Track [Page 9]
RFC 2837 FC Fabric Element MIB May 2000 SYNTAX FcFeModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing the configuration parameters of a module." INDEX { fcFeModuleIndex } ::= { fcFeModuleTable 1 } FcFeModuleEntry ::= SEQUENCE { fcFeModuleIndex FcFeModuleIndex, fcFeModuleDescr SnmpAdminString, fcFeModuleObjectID OBJECT IDENTIFIER, fcFeModuleOperStatus INTEGER, fcFeModuleLastChange TimeStamp, fcFeModuleFxPortCapacity FcFeFxPortCapacity, fcFeModuleName FcNameId } fcFeModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the module within the Fabric Element for which this entry contains information. This value is never greater than fcFeModuleCapacity." ::= { fcFeModuleEntry 1 } fcFeModuleDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the module. This value should include the full name and version identification of the module." ::= { fcFeModuleEntry 2 } Teow Standards Track [Page 10]
RFC 2837 FC Fabric Element MIB May 2000 fcFeModuleObjectID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The vendor's authoritative identification of the module. This value may be allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides a straight-forward and unambiguous means for determining what kind of module is being managed. For example, this object could take the value 1.3.6.1.4.1.99649.3.9 if vendor 'Neufe Inc.' was assigned the subtree 1.3.6.1.4.1.99649, and had assigned the identifier 1.3.6.1.4.1.99649.3.9 to its 'FeFiFo-16 PlugInCard.'" ::= { fcFeModuleEntry 3 } fcFeModuleOperStatus OBJECT-TYPE SYNTAX INTEGER { online (1), -- functional offline (2), -- not available testing (3), -- under testing faulty (4) -- defective } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the operational status of the module: online(1) the module is functioning properly; offline(2) the module is not available; testing(3) the module is under testing; and faulty(4) the module is defective in some way." ::= { fcFeModuleEntry 4 } fcFeModuleLastChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the value of sysUpTime when the module entered its current operational status. A value of zero indicates that the operational status of the module has not changed since the agent last restarted." ::= { fcFeModuleEntry 5 } fcFeModuleFxPortCapacity OBJECT-TYPE SYNTAX FcFeFxPortCapacity Teow Standards Track [Page 11]
RFC 2837 FC Fabric Element MIB May 2000 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of FxPort that can be contained within the module. Within each module, the ports are uniquely numbered in the range from 1 to fcFeModuleFxPortCapacity inclusive. However, the numbers are not required to be contiguous." ::= { fcFeModuleEntry 6 } fcFeModuleName OBJECT-TYPE SYNTAX FcNameId MAX-ACCESS read-write STATUS current DESCRIPTION "The Name_Identifier of the module." ::= { fcFeModuleEntry 7 } -- the FxPort Configuration Table. -- This table contains, one entry for each FxPort, -- configuration parameters of the ports. fcFxPortTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, configuration and service parameters of the FxPorts." ::= { fcFeConfig 5 } fcFxPortEntry OBJECT-TYPE SYNTAX FcFxPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing the configuration and service parameters of a FxPort." INDEX { fcFeModuleIndex, fcFxPortIndex } ::= { fcFxPortTable 1 } FcFxPortEntry ::= SEQUENCE { fcFxPortIndex FcFeFxPortIndex, fcFxPortName FcNameId, Teow Standards Track [Page 12]
RFC 2837 FC Fabric Element MIB May 2000 -- FxPort common service parameters fcFxPortFcphVersionHigh FcphVersion, fcFxPortFcphVersionLow FcphVersion, fcFxPortBbCredit FcBbCredit, fcFxPortRxBufSize FcRxDataFieldSize, fcFxPortRatov MilliSeconds, fcFxPortEdtov MilliSeconds, -- FxPort class service parameters fcFxPortCosSupported FcCosCap, fcFxPortIntermixSupported TruthValue, fcFxPortStackedConnMode FcStackedConnMode, fcFxPortClass2SeqDeliv TruthValue, fcFxPortClass3SeqDeliv TruthValue, -- other configuration parameters fcFxPortHoldTime MicroSeconds } fcFxPortIndex OBJECT-TYPE SYNTAX FcFeFxPortIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the FxPort within the module. This number ranges from 1 to the value of fcFeModulePortCapacity for the associated module. The value remains constant for the identified FxPort until the module is re-initialized." ::= { fcFxPortEntry 1 } fcFxPortName OBJECT-TYPE SYNTAX FcNameId MAX-ACCESS read-only STATUS current DESCRIPTION "The World_wide Name of this FxPort. Each FxPort has a unique Port World_wide Name within the Fabric." ::= { fcFxPortEntry 2 } Teow Standards Track [Page 13]
RFC 2837 FC Fabric Element MIB May 2000 -- FxPort common service parameters fcFxPortFcphVersionHigh OBJECT-TYPE SYNTAX FcphVersion MAX-ACCESS read-only STATUS current DESCRIPTION "The highest or most recent version of FC-PH that the FxPort is configured to support." ::= { fcFxPortEntry 3 } fcFxPortFcphVersionLow OBJECT-TYPE SYNTAX FcphVersion MAX-ACCESS read-only STATUS current DESCRIPTION "The lowest or earliest version of FC-PH that the FxPort is configured to support." ::= { fcFxPortEntry 4 } fcFxPortBbCredit OBJECT-TYPE SYNTAX FcBbCredit UNITS "buffers" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of receive buffers available for holding Class 1 connect-request, Class 2 or 3 frames from the attached NxPort. It is for buffer-to-buffer flow control in the direction from the attached NxPort (if applicable) to FxPort." ::= { fcFxPortEntry 5 } fcFxPortRxBufSize OBJECT-TYPE SYNTAX FcRxDataFieldSize UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The largest Data_Field Size (in octets) for an FT_1 frame that can be received by the FxPort." ::= { fcFxPortEntry 6 } fcFxPortRatov OBJECT-TYPE SYNTAX MilliSeconds UNITS "milliseconds" MAX-ACCESS read-only STATUS current Teow Standards Track [Page 14]
RFC 2837 FC Fabric Element MIB May 2000 DESCRIPTION "The Resource_Allocation_Timeout Value configured for the FxPort. This is used as the timeout value for determining when to reuse an NxPort resource such as a Recovery_Qualifier. It represents E_D_TOV (see next object) plus twice the maximum time that a frame may be delayed within the Fabric and still be delivered." ::= { fcFxPortEntry 7 } fcFxPortEdtov OBJECT-TYPE SYNTAX MilliSeconds UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The E_D_TOV value configured for the FxPort. The Error_Detect_Timeout Value is used as the timeout value for detecting an error condition." ::= { fcFxPortEntry 8 } -- FxPort class service parameters fcFxPortCosSupported OBJECT-TYPE SYNTAX FcCosCap MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating the set of Classes of Service supported by the FxPort." ::= { fcFxPortEntry 9 } fcFxPortIntermixSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not the FxPort supports an Intermixed Dedicated Connection." ::= { fcFxPortEntry 10 } fcFxPortStackedConnMode OBJECT-TYPE SYNTAX FcStackedConnMode MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating the mode of Stacked Connect supported by the FxPort." Teow Standards Track [Page 15]
RFC 2837 FC Fabric Element MIB May 2000 ::= { fcFxPortEntry 11 } fcFxPortClass2SeqDeliv OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not Class 2 Sequential Delivery is supported by the FxPort." ::= { fcFxPortEntry 12 } fcFxPortClass3SeqDeliv OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not Class 3 Sequential Delivery is supported by the FxPort." ::= { fcFxPortEntry 13 } -- other FxPort parameters fcFxPortHoldTime OBJECT-TYPE SYNTAX MicroSeconds UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum time (in microseconds) that the FxPort shall hold a frame before discarding the frame if it is unable to deliver the frame. The value 0 means that the FxPort does not support this parameter." ::= { fcFxPortEntry 14 } -- the Status group -- This group consists of tables that contains operational -- status and established service parameters for the Fabric -- Element and the attached NxPorts. -- The FxPort Status table -- This table contains, one entry for each FxPort, -- the operational status and parameters of the FxPorts. fcFxPortStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortStatusEntry Teow Standards Track [Page 16]
RFC 2837 FC Fabric Element MIB May 2000 MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, operational status and parameters of the FxPorts." ::= { fcFeStatus 1 } fcFxPortStatusEntry OBJECT-TYPE SYNTAX FcFxPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing operational status and parameters of a FxPort." AUGMENTS { fcFxPortEntry } ::= { fcFxPortStatusTable 1 } FcFxPortStatusEntry ::= SEQUENCE { fcFxPortID FcAddressId, fcFxPortBbCreditAvailable Gauge32, fcFxPortOperMode INTEGER, fcFxPortAdminMode INTEGER } fcFxPortID OBJECT-TYPE SYNTAX FcAddressId MAX-ACCESS read-only STATUS current DESCRIPTION "The address identifier by which this FxPort is identified within the Fabric. The FxPort may assign its address identifier to its attached NxPort(s) during Fabric Login." ::= { fcFxPortStatusEntry 1 } fcFxPortBbCreditAvailable OBJECT-TYPE SYNTAX Gauge32 UNITS "buffers" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of buffers currently available for receiving Teow Standards Track [Page 17]
RFC 2837 FC Fabric Element MIB May 2000 frames from the attached port in the buffer-to-buffer flow control. The value should be less than or equal to fcFxPortBbCredit." ::= { fcFxPortStatusEntry 2 } fcFxPortOperMode OBJECT-TYPE SYNTAX INTEGER { unknown(1), fPort(2), flPort(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational mode of the FxPort." ::= { fcFxPortStatusEntry 3 } fcFxPortAdminMode OBJECT-TYPE SYNTAX INTEGER { fPort(2), flPort(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired operational mode of the FxPort." ::= { fcFxPortStatusEntry 4 } -- the FxPort Physical Level table -- This table contains, one entry for each FxPort in the -- Fabric Element, the physical level status and parameters -- of the FxPorts. fcFxPortPhysTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortPhysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, physical level status and parameters of the FxPorts." ::= { fcFeStatus 2 } fcFxPortPhysEntry OBJECT-TYPE SYNTAX FcFxPortPhysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing physical level status and parameters of a FxPort." AUGMENTS { fcFxPortEntry } ::= { fcFxPortPhysTable 1 } FcFxPortPhysEntry ::= Teow Standards Track [Page 18]
RFC 2837 FC Fabric Element MIB May 2000 SEQUENCE { fcFxPortPhysAdminStatus INTEGER, fcFxPortPhysOperStatus INTEGER, fcFxPortPhysLastChange TimeStamp, fcFxPortPhysRttov MilliSeconds } fcFxPortPhysAdminStatus OBJECT-TYPE SYNTAX INTEGER { online (1), -- place port online offline (2), -- take port offline testing (3) -- initiate test procedures } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired state of the FxPort. A management station may place the FxPort in a desired state by setting this object accordingly. The testing(3) state indicates that no operational frames can be passed. When a Fabric Element initializes, all FxPorts start with fcFxPortPhysAdminStatus in the offline(2) state. As the result of either explicit management action or per configuration information accessible by the Fabric Element, fcFxPortPhysAdminStatus is then changed to either the online(1) or testing(3) states, or remains in the offline state." ::= { fcFxPortPhysEntry 1 } fcFxPortPhysOperStatus OBJECT-TYPE SYNTAX INTEGER { online (1), -- Login may proceed offline (2), -- Login cannot proceed testing (3), -- port is under test linkFailure (4) -- failure after online/testing } MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational status of the FxPort. The testing(3) indicates that no operational frames can be passed. If fcFxPortPhysAdminStatus is offline(2) then fcFxPortPhysOperStatus should be offline(2). If fcFxPortPhysAdminStatus is changed to online(1) then fcFxPortPhysOperStatus should change to online(1) if the Teow Standards Track [Page 19]
RFC 2837 FC Fabric Element MIB May 2000 FxPort is ready to accept Fabric Login request from the attached NxPort; it should proceed and remain in the link- failure(4) state if and only if there is a fault that prevents it from going to the online(1) state." ::= { fcFxPortPhysEntry 2 } fcFxPortPhysLastChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the FxPort entered its current operational status. A value of zero indicates that the FxPort's operational status has not changed since the agent last restarted." ::= { fcFxPortPhysEntry 3 } fcFxPortPhysRttov OBJECT-TYPE SYNTAX MilliSeconds UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "The Receiver_Transmitter_Timeout value of the FxPort. This is used by the receiver logic to detect Loss of Synchronization." ::= { fcFxPortPhysEntry 4 } -- The FxPort Fabric Login table -- -- This table contains, one entry for each FxPort in the -- Fabric Element, the Service Parameters that have been -- established from the most recent Fabric Login, -- implicit or explicit. fcFxLoginTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxLoginEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each NxPort attached to a particular FxPort in the Fabric Element, services parameters established from the most recent Fabric Login, explicit or implicit. Note that an FxPort may have one or more NxPort attached to it." ::= { fcFeStatus 3 } Teow Standards Track [Page 20]
RFC 2837 FC Fabric Element MIB May 2000 fcFxLoginEntry OBJECT-TYPE SYNTAX FcFxLoginEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing service parameters established from a successful Fabric Login." INDEX { fcFeModuleIndex, fcFxPortIndex, fcFxPortNxLoginIndex } ::= { fcFxLoginTable 1 } FcFxLoginEntry ::= SEQUENCE { fcFxPortNxLoginIndex FcFeNxPortIndex, fcFxPortFcphVersionAgreed FcphVersion, fcFxPortNxPortBbCredit FcBbCredit, fcFxPortNxPortRxDataFieldSize FcRxDataFieldSize, fcFxPortCosSuppAgreed FcCosCap, fcFxPortIntermixSuppAgreed TruthValue, fcFxPortStackedConnModeAgreed FcStackedConnMode, fcFxPortClass2SeqDelivAgreed TruthValue, fcFxPortClass3SeqDelivAgreed TruthValue, -- fcFxPortNxPortName FcNameId, fcFxPortConnectedNxPort FcAddressId, fcFxPortBbCreditModel FcBbCreditModel } fcFxPortNxLoginIndex OBJECT-TYPE SYNTAX FcFeNxPortIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The object identifies the associated NxPort in the attachment for which the entry contains information." ::= { fcFxLoginEntry 1 } Teow Standards Track [Page 21]
RFC 2837 FC Fabric Element MIB May 2000 fcFxPortFcphVersionAgreed OBJECT-TYPE SYNTAX FcphVersion MAX-ACCESS read-only STATUS current DESCRIPTION "The version of FC-PH that the FxPort has agreed to support from the Fabric Login" ::= { fcFxLoginEntry 2 } fcFxPortNxPortBbCredit OBJECT-TYPE SYNTAX FcBbCredit UNITS "buffers" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of buffers available for holding Class 1 connect-request, Class 2 or Class 3 frames to be transmitted to the attached NxPort. It is for buffer-to- buffer flow control in the direction from FxPort to NxPort. The buffer-to-buffer flow control mechanism is indicated in the respective fcFxPortBbCreditModel." ::= { fcFxLoginEntry 3 } fcFxPortNxPortRxDataFieldSize OBJECT-TYPE SYNTAX FcRxDataFieldSize UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The Receive Data Field Size of the attached NxPort. This object specifies the largest Data Field Size for an FT_1 frame that can be received by the NxPort." ::= { fcFxLoginEntry 4 } fcFxPortCosSuppAgreed OBJECT-TYPE SYNTAX FcCosCap MAX-ACCESS read-only STATUS current DESCRIPTION "A variable indicating that the attached NxPort has requested the FxPort for the support of classes of services and the FxPort has granted the request." ::= { fcFxLoginEntry 5 } fcFxPortIntermixSuppAgreed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current Teow Standards Track [Page 22]
RFC 2837 FC Fabric Element MIB May 2000 DESCRIPTION "A variable indicating that the attached NxPort has requested the FxPort for the support of Intermix and the FxPort has granted the request. This flag is only valid if Class 1 service is supported." ::= { fcFxLoginEntry 6 } fcFxPortStackedConnModeAgreed OBJECT-TYPE SYNTAX FcStackedConnMode MAX-ACCESS read-only STATUS current DESCRIPTION "A variable indicating whether the FxPort has agreed to support stacked connect from the Fabric Login. This is only meaningful if Class 1 service has been agreed." ::= { fcFxLoginEntry 7 } fcFxPortClass2SeqDelivAgreed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A variable indicating whether the FxPort has agreed to support Class 2 sequential delivery from the Fabric Login. This is only meaningful if Class 2 service has been agreed." ::= { fcFxLoginEntry 8 } fcFxPortClass3SeqDelivAgreed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether the FxPort has agreed to support Class 3 sequential delivery from the Fabric Login. This is only meaningful if Class 3 service has been agreed." ::= { fcFxLoginEntry 9 } fcFxPortNxPortName OBJECT-TYPE SYNTAX FcNameId MAX-ACCESS read-only STATUS current DESCRIPTION "The port name of the attached NxPort." ::= { fcFxLoginEntry 10 } fcFxPortConnectedNxPort OBJECT-TYPE SYNTAX FcAddressId Teow Standards Track [Page 23]
RFC 2837 FC Fabric Element MIB May 2000 MAX-ACCESS read-only STATUS current DESCRIPTION "The address identifier of the destination NxPort with which this FxPort is currently engaged in a either a Class 1 or loop connection. If this FxPort is not engaged in a connection, then the value of this object is '000000'H." ::= { fcFxLoginEntry 11 } fcFxPortBbCreditModel OBJECT-TYPE SYNTAX FcBbCreditModel MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the BB_Credit model used by the FxPort." ::= { fcFxLoginEntry 12 } -- the Error group -- This group consists of tables that contain information about -- the various types of errors detected. The management station -- may use the information in this group to determine the -- quality of the link between the FxPort and its attached NxPort. -- the FxPort Error table -- This table contains, one entry for each FxPort in the Fabric -- Element, counters recording numbers of errors detected -- since the management agent re-initialized. -- The first 6 columnar objects after the port index corresponds -- to the counters in the Link Error Status Block. fcFxPortErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each FxPort, counters that record the numbers of errors detected." ::= { fcFeError 1 } fcFxPortErrorEntry OBJECT-TYPE SYNTAX FcFxPortErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing error counters of a FxPort." AUGMENTS { fcFxPortEntry } Teow Standards Track [Page 24]
RFC 2837 FC Fabric Element MIB May 2000 ::= { fcFxPortErrorTable 1 } FcFxPortErrorEntry ::= SEQUENCE { fcFxPortLinkFailures Counter32, fcFxPortSyncLosses Counter32, fcFxPortSigLosses Counter32, fcFxPortPrimSeqProtoErrors Counter32, fcFxPortInvalidTxWords Counter32, fcFxPortInvalidCrcs Counter32, fcFxPortDelimiterErrors Counter32, fcFxPortAddressIdErrors Counter32, fcFxPortLinkResetIns Counter32, fcFxPortLinkResetOuts Counter32, fcFxPortOlsIns Counter32, fcFxPortOlsOuts Counter32 } fcFxPortLinkFailures OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of link failures detected by this FxPort." ::= { fcFxPortErrorEntry 1 } fcFxPortSyncLosses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of loss of synchronization detected by the FxPort." ::= { fcFxPortErrorEntry 2 } Teow Standards Track [Page 25]
RFC 2837 FC Fabric Element MIB May 2000 fcFxPortSigLosses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of loss of signal detected by the FxPort." ::= { fcFxPortErrorEntry 3 } fcFxPortPrimSeqProtoErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of primitive sequence protocol errors detected by the FxPort." ::= { fcFxPortErrorEntry 4 } fcFxPortInvalidTxWords OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of invalid transmission word detected by the FxPort." ::= { fcFxPortErrorEntry 5 } fcFxPortInvalidCrcs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of invalid CRC detected by this FxPort." ::= { fcFxPortErrorEntry 6 } fcFxPortDelimiterErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Delimiter Errors detected by this FxPort." ::= { fcFxPortErrorEntry 7 } fcFxPortAddressIdErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of address identifier errors detected by this Teow Standards Track [Page 26]
RFC 2837 FC Fabric Element MIB May 2000 FxPort." ::= { fcFxPortErrorEntry 8 } fcFxPortLinkResetIns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Link Reset Protocol received by this FxPort from the attached NxPort." ::= { fcFxPortErrorEntry 9 } fcFxPortLinkResetOuts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Link Reset Protocol issued by this FxPort to the attached NxPort." ::= { fcFxPortErrorEntry 10 } fcFxPortOlsIns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Offline Sequence received by this FxPort." ::= { fcFxPortErrorEntry 11 } fcFxPortOlsOuts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Offline Sequence issued by this FxPort." ::= { fcFxPortErrorEntry 12 } -- Accounting Groups: -- (1) Class 1 Accounting Group, -- (2) Class 2 Accounting Group, and -- (3) Class 3 Accounting Group. -- Each group consists of a table that contains accounting -- information for the FxPorts in the Fabric Element. -- the Class 1 Accounting table -- This table contains, one entry for each FxPort in the Fabric Teow Standards Track [Page 27]
RFC 2837 FC Fabric Element MIB May 2000 -- Element, Counter32s for certain types of events occurred in the -- the FxPorts since the the management agent has re-initialized. fcFxPortC1AccountingTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortC1AccountingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, Class 1 accounting information recorded since the management agent has re-initialized." ::= { fcFeAccounting 1 } fcFxPortC1AccountingEntry OBJECT-TYPE SYNTAX FcFxPortC1AccountingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing Class 1 accounting information for each FxPort." AUGMENTS { fcFxPortEntry } ::= { fcFxPortC1AccountingTable 1 } FcFxPortC1AccountingEntry ::= SEQUENCE { fcFxPortC1InFrames Counter32, fcFxPortC1OutFrames Counter32, fcFxPortC1InOctets Counter32, fcFxPortC1OutOctets Counter32, fcFxPortC1Discards Counter32, fcFxPortC1FbsyFrames Counter32, fcFxPortC1FrjtFrames Counter32, fcFxPortC1InConnections Counter32, fcFxPortC1OutConnections Counter32, fcFxPortC1ConnTime MilliSeconds } Teow Standards Track [Page 28]
RFC 2837 FC Fabric Element MIB May 2000 fcFxPortC1InFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 1 frames (other than Class 1 connect- request) received by this FxPort from its attached NxPort." ::= { fcFxPortC1AccountingEntry 1 } fcFxPortC1OutFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 1 frames (other than Class 1 connect- request) delivered through this FxPort to its attached NxPort." ::= { fcFxPortC1AccountingEntry 2 } fcFxPortC1InOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 1 frame octets, including the frame delimiters, received by this FxPort from its attached NxPort." ::= { fcFxPortC1AccountingEntry 3 } fcFxPortC1OutOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 1 frame octets, including the frame delimiters, delivered through this FxPort its attached NxPort." ::= { fcFxPortC1AccountingEntry 4 } fcFxPortC1Discards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 1 frames discarded by this FxPort." ::= { fcFxPortC1AccountingEntry 5 } fcFxPortC1FbsyFrames OBJECT-TYPE Teow Standards Track [Page 29]
RFC 2837 FC Fabric Element MIB May 2000 SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of F_BSY frames generated by this FxPort against Class 1 connect-request." ::= { fcFxPortC1AccountingEntry 6 } fcFxPortC1FrjtFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of F_RJT frames generated by this FxPort against Class 1 connect-request." ::= { fcFxPortC1AccountingEntry 7 } fcFxPortC1InConnections OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 1 connections successfully established in which the attached NxPort is the source of the connect- request." ::= { fcFxPortC1AccountingEntry 8 } fcFxPortC1OutConnections OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 1 connections successfully established in which the attached NxPort is the destination of the connect-request." ::= { fcFxPortC1AccountingEntry 9 } fcFxPortC1ConnTime OBJECT-TYPE SYNTAX MilliSeconds UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The cumulative time that this FxPort has been engaged in Class 1 connection. The amount of time is counted from after a connect-request has been accepted until the connection is disengaged, either by an EOFdt or Link Reset." Teow Standards Track [Page 30]
RFC 2837 FC Fabric Element MIB May 2000 ::= { fcFxPortC1AccountingEntry 10 } -- the Class 2 Accounting table -- This table contains, one entry for each FxPort in the Fabric -- Element, Counter32s for certain types of events occurred in the -- the FxPorts since the the management agent has re-initialized. fcFxPortC2AccountingTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortC2AccountingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, Class 2 accounting information recorded since the management agent has re-initialized." ::= { fcFeAccounting 2 } fcFxPortC2AccountingEntry OBJECT-TYPE SYNTAX FcFxPortC2AccountingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing Class 2 accounting information for each FxPort." AUGMENTS { fcFxPortEntry } ::= { fcFxPortC2AccountingTable 1 } FcFxPortC2AccountingEntry ::= SEQUENCE { fcFxPortC2InFrames Counter32, fcFxPortC2OutFrames Counter32, fcFxPortC2InOctets Counter32, fcFxPortC2OutOctets Counter32, fcFxPortC2Discards Counter32, fcFxPortC2FbsyFrames Counter32, fcFxPortC2FrjtFrames Counter32 } fcFxPortC2InFrames OBJECT-TYPE Teow Standards Track [Page 31]
RFC 2837 FC Fabric Element MIB May 2000 SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames received by this FxPort from its attached NxPort." ::= { fcFxPortC2AccountingEntry 1 } fcFxPortC2OutFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames delivered through this FxPort to its attached NxPort." ::= { fcFxPortC2AccountingEntry 2 } fcFxPortC2InOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frame octets, including the frame delimiters, received by this FxPort from its attached NxPort." ::= { fcFxPortC2AccountingEntry 3 } fcFxPortC2OutOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frame octets, including the frame delimiters, delivered through this FxPort to its attached NxPort." ::= { fcFxPortC2AccountingEntry 4 } fcFxPortC2Discards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames discarded by this FxPort." ::= { fcFxPortC2AccountingEntry 5 } fcFxPortC2FbsyFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only Teow Standards Track [Page 32]
RFC 2837 FC Fabric Element MIB May 2000 STATUS current DESCRIPTION "The number of F_BSY frames generated by this FxPort against Class 2 frames." ::= { fcFxPortC2AccountingEntry 6 } fcFxPortC2FrjtFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of F_RJT frames generated by this FxPort against Class 2 frames." ::= { fcFxPortC2AccountingEntry 7 } -- the Class 3 Accounting Group -- This table contains, one entry for each FxPort in the Fabric -- Element, Counter32s for certain types of events occurred in the -- the FxPorts since the management agent has re-initialized. fcFxPortC3AccountingTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortC3AccountingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, Class 3 accounting information recorded since the management agent has re-initialized." ::= { fcFeAccounting 3 } fcFxPortC3AccountingEntry OBJECT-TYPE SYNTAX FcFxPortC3AccountingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing Class 3 accounting information for each FxPort." AUGMENTS { fcFxPortEntry } ::= { fcFxPortC3AccountingTable 1 } FcFxPortC3AccountingEntry ::= SEQUENCE { fcFxPortC3InFrames Counter32, fcFxPortC3OutFrames Counter32, fcFxPortC3InOctets Teow Standards Track [Page 33]
RFC 2837 FC Fabric Element MIB May 2000 Counter32, fcFxPortC3OutOctets Counter32, fcFxPortC3Discards Counter32 } fcFxPortC3InFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames received by this FxPort from its attached NxPort." ::= { fcFxPortC3AccountingEntry 1 } fcFxPortC3OutFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames delivered through this FxPort to its attached NxPort." ::= { fcFxPortC3AccountingEntry 2 } fcFxPortC3InOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frame octets, including the frame delimiters, received by this FxPort from its attached NxPort." ::= { fcFxPortC3AccountingEntry 3 } fcFxPortC3OutOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frame octets, including the frame delimiters, delivered through this FxPort to its attached NxPort." ::= { fcFxPortC3AccountingEntry 4 } fcFxPortC3Discards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only Teow Standards Track [Page 34]
RFC 2837 FC Fabric Element MIB May 2000 STATUS current DESCRIPTION "The number of Class 3 frames discarded by this FxPort." ::= { fcFxPortC3AccountingEntry 5 } -- The Capability Group - consists of a table describing -- information about what each FxPort is inherently capable -- of operating or supporting. -- A capability may be used, as expressed in its respective -- object value in the Configuration group. fcFxPortCapTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortCapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each FxPort, the capabilities of the port within the Fabric Element." ::= { fcFeCapabilities 1 } fcFxPortCapEntry OBJECT-TYPE SYNTAX FcFxPortCapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing the Cap of a FxPort." AUGMENTS { fcFxPortEntry } ::= { fcFxPortCapTable 1 } FcFxPortCapEntry ::= SEQUENCE { fcFxPortCapFcphVersionHigh FcphVersion, fcFxPortCapFcphVersionLow FcphVersion, fcFxPortCapBbCreditMax FcBbCredit, fcFxPortCapBbCreditMin FcBbCredit, fcFxPortCapRxDataFieldSizeMax FcRxDataFieldSize, fcFxPortCapRxDataFieldSizeMin FcRxDataFieldSize, fcFxPortCapCos FcCosCap, fcFxPortCapIntermix Teow Standards Track [Page 35]
RFC 2837 FC Fabric Element MIB May 2000 TruthValue, fcFxPortCapStackedConnMode FcStackedConnMode, fcFxPortCapClass2SeqDeliv TruthValue, fcFxPortCapClass3SeqDeliv TruthValue, fcFxPortCapHoldTimeMax MicroSeconds, fcFxPortCapHoldTimeMin MicroSeconds } fcFxPortCapFcphVersionHigh OBJECT-TYPE SYNTAX FcphVersion MAX-ACCESS read-only STATUS current DESCRIPTION "The highest or most recent version of FC-PH that the FxPort is capable of supporting." ::= { fcFxPortCapEntry 1 } fcFxPortCapFcphVersionLow OBJECT-TYPE SYNTAX FcphVersion MAX-ACCESS read-only STATUS current DESCRIPTION "The lowest or earliest version of FC-PH that the FxPort is capable of supporting." ::= { fcFxPortCapEntry 2 } fcFxPortCapBbCreditMax OBJECT-TYPE SYNTAX FcBbCredit UNITS "buffers" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of receive buffers available for holding Class 1 connect-request, Class 2 or Class 3 frames from the attached NxPort." ::= { fcFxPortCapEntry 3 } fcFxPortCapBbCreditMin OBJECT-TYPE SYNTAX FcBbCredit UNITS "buffers" MAX-ACCESS read-only STATUS current DESCRIPTION Teow Standards Track [Page 36]
RFC 2837 FC Fabric Element MIB May 2000 "The minimum number of receive buffers available for holding Class 1 connect-request, Class 2 or Class 3 frames from the attached NxPort." ::= { fcFxPortCapEntry 4 } fcFxPortCapRxDataFieldSizeMax OBJECT-TYPE SYNTAX FcRxDataFieldSize UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum size in bytes of the Data Field in a frame that the FxPort is capable of receiving from its attached NxPort." ::= { fcFxPortCapEntry 5 } fcFxPortCapRxDataFieldSizeMin OBJECT-TYPE SYNTAX FcRxDataFieldSize UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum size in bytes of the Data Field in a frame that the FxPort is capable of receiving from its attached NxPort." ::= { fcFxPortCapEntry 6 } fcFxPortCapCos OBJECT-TYPE SYNTAX FcCosCap MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating the set of Classes of Service that the FxPort is capable of supporting." ::= { fcFxPortCapEntry 7 } fcFxPortCapIntermix OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not the FxPort is capable of supporting the intermixing of Class 2 and Class 3 frames during a Class 1 connection. This flag is only valid if the port is capable of supporting Class 1 service." ::= { fcFxPortCapEntry 8 } fcFxPortCapStackedConnMode OBJECT-TYPE Teow Standards Track [Page 37]
RFC 2837 FC Fabric Element MIB May 2000 SYNTAX FcStackedConnMode MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating the mode of Stacked Connect request that the FxPort is capable of supporting." ::= { fcFxPortCapEntry 9 } fcFxPortCapClass2SeqDeliv OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not the FxPort is capable of supporting Class 2 Sequential Delivery." ::= { fcFxPortCapEntry 10 } fcFxPortCapClass3SeqDeliv OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A flag indicating whether or not the FxPort is capable of supporting Class 3 Sequential Delivery." ::= { fcFxPortCapEntry 11 } fcFxPortCapHoldTimeMax OBJECT-TYPE SYNTAX MicroSeconds UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum holding time (in microseconds) that the FxPort is capable of supporting." ::= { fcFxPortCapEntry 12 } fcFxPortCapHoldTimeMin OBJECT-TYPE SYNTAX MicroSeconds UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum holding time (in microseconds) that the FxPort is capable of supporting." ::= { fcFxPortCapEntry 13 } -- conformance information Teow Standards Track [Page 38]
RFC 2837 FC Fabric Element MIB May 2000 fcFeMIBConformance OBJECT IDENTIFIER ::= { fcFeMIB 2 } fcFeMIBCompliances OBJECT IDENTIFIER ::= { fcFeMIBConformance 1 } fcFeMIBGroups OBJECT IDENTIFIER ::= { fcFeMIBConformance 2 } -- compliance statements fcFeMIBMinimumCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The minimum compliance statement for SNMP entities which implement the FIBRE-CHANNEL-FE-MIB." MODULE -- this module MANDATORY-GROUPS { fcFeConfigGroup, fcFeStatusGroup, fcFeErrorGroup } OBJECT fcFeFabricName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT fcFeElementName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT fcFeModuleName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT fcFxPortAdminMode MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT fcFxPortPhysAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT fcFxPortPhysRttov MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT fcFxPortBbCreditModel MIN-ACCESS read-only DESCRIPTION "Write access is not required." Teow Standards Track [Page 39]
RFC 2837 FC Fabric Element MIB May 2000 ::= { fcFeMIBCompliances 1 } fcFeMIBFullCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The full compliance statement for SNMP entities which implement the FIBRE-CHANNEL-FE-MIB." MODULE -- this module MANDATORY-GROUPS { fcFeConfigGroup, fcFeStatusGroup, fcFeErrorGroup, fcFeCapabilitiesGroup } GROUP fcFeClass1AccountingGroup DESCRIPTION "This group is mandatory for all fibre channel fabric elements which support class 1 frames." GROUP fcFeClass2AccountingGroup DESCRIPTION "This group is mandatory for all fibre channel fabric elements which support class 2 frames." GROUP fcFeClass3AccountingGroup DESCRIPTION "This group is mandatory for all fibre channel fabric elements which support class 3 frames." OBJECT fcFeFabricName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT fcFeElementName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT fcFeModuleName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT fcFxPortAdminMode MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT fcFxPortPhysAdminStatus MIN-ACCESS read-only Teow Standards Track [Page 40]
RFC 2837 FC Fabric Element MIB May 2000 DESCRIPTION "Write access is not required." OBJECT fcFxPortPhysRttov MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT fcFxPortBbCreditModel MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { fcFeMIBCompliances 2 } -- units of conformance fcFeConfigGroup OBJECT-GROUP OBJECTS { fcFeFabricName, fcFeElementName, fcFeModuleCapacity, fcFeModuleDescr, fcFeModuleObjectID, fcFeModuleOperStatus, fcFeModuleLastChange, fcFeModuleFxPortCapacity, fcFeModuleName, fcFxPortName, fcFxPortFcphVersionHigh, fcFxPortFcphVersionLow, fcFxPortBbCredit, fcFxPortRxBufSize, fcFxPortRatov, fcFxPortEdtov, fcFxPortCosSupported, fcFxPortIntermixSupported, fcFxPortStackedConnMode, fcFxPortClass2SeqDeliv, fcFxPortClass3SeqDeliv, fcFxPortHoldTime } STATUS current DESCRIPTION "A collection of objects providing the configuration and service parameters of the Fabric Element, the modules, and FxPorts." ::= { fcFeMIBGroups 1 } fcFeStatusGroup OBJECT-GROUP OBJECTS { fcFxPortID, fcFxPortBbCreditAvailable, fcFxPortOperMode, fcFxPortAdminMode, fcFxPortPhysAdminStatus, fcFxPortPhysOperStatus, fcFxPortPhysLastChange, fcFxPortPhysRttov, fcFxPortFcphVersionAgreed, fcFxPortNxPortBbCredit, fcFxPortNxPortRxDataFieldSize, fcFxPortCosSuppAgreed, fcFxPortIntermixSuppAgreed, fcFxPortStackedConnModeAgreed, fcFxPortClass2SeqDelivAgreed, fcFxPortClass3SeqDelivAgreed, fcFxPortNxPortName, fcFxPortConnectedNxPort, fcFxPortBbCreditModel } STATUS current DESCRIPTION Teow Standards Track [Page 41]
RFC 2837 FC Fabric Element MIB May 2000 "A collection of objects providing the operational status and established service parameters for the Fabric Element and the attached NxPorts." ::= { fcFeMIBGroups 2 } fcFeErrorGroup OBJECT-GROUP OBJECTS { fcFxPortLinkFailures, fcFxPortSyncLosses, fcFxPortSigLosses, fcFxPortPrimSeqProtoErrors, fcFxPortInvalidTxWords, fcFxPortInvalidCrcs, fcFxPortDelimiterErrors, fcFxPortAddressIdErrors, fcFxPortLinkResetIns, fcFxPortLinkResetOuts, fcFxPortOlsIns, fcFxPortOlsOuts } STATUS current DESCRIPTION "A collection of objects providing various error statistics detected by the FxPorts." ::= { fcFeMIBGroups 3 } fcFeClass1AccountingGroup OBJECT-GROUP OBJECTS { fcFxPortC1InFrames, fcFxPortC1OutFrames, fcFxPortC1InOctets, fcFxPortC1OutOctets, fcFxPortC1Discards, fcFxPortC1FbsyFrames, fcFxPortC1FrjtFrames, fcFxPortC1InConnections, fcFxPortC1OutConnections, fcFxPortC1ConnTime } STATUS current DESCRIPTION "A collection of objects providing various class 1 performance statistics detected by the FxPorts." ::= { fcFeMIBGroups 4 } fcFeClass2AccountingGroup OBJECT-GROUP OBJECTS { fcFxPortC2InFrames, fcFxPortC2OutFrames, fcFxPortC2InOctets, fcFxPortC2OutOctets, fcFxPortC2Discards, fcFxPortC2FbsyFrames, fcFxPortC2FrjtFrames } STATUS current DESCRIPTION "A collection of objects providing various class 2 performance statistics detected by the FxPorts." ::= { fcFeMIBGroups 5 } fcFeClass3AccountingGroup OBJECT-GROUP OBJECTS { fcFxPortC3InFrames, fcFxPortC3OutFrames, fcFxPortC3InOctets, fcFxPortC3OutOctets, fcFxPortC3Discards } Teow Standards Track [Page 42]
RFC 2837 FC Fabric Element MIB May 2000 STATUS current DESCRIPTION "A collection of objects providing various class 3 performance statistics detected by the FxPorts." ::= { fcFeMIBGroups 6 } fcFeCapabilitiesGroup OBJECT-GROUP OBJECTS { fcFxPortCapFcphVersionHigh, fcFxPortCapFcphVersionLow, fcFxPortCapBbCreditMax, fcFxPortCapBbCreditMin, fcFxPortCapRxDataFieldSizeMax, fcFxPortCapRxDataFieldSizeMin, fcFxPortCapCos, fcFxPortCapIntermix, fcFxPortCapStackedConnMode, fcFxPortCapClass2SeqDeliv, fcFxPortCapClass3SeqDeliv, fcFxPortCapHoldTimeMax, fcFxPortCapHoldTimeMin } STATUS current DESCRIPTION "A collection of objects providing the inherent capability of each FxPort within the Fabric Element." ::= { fcFeMIBGroups 7 } END -- End of Object Definitions 4. Security Considerations There are a number of management objects defined in this MIB that have a MAX-ACCESS clause of read-write. Such objects may be considered sensitive or vulnerable in some network environments. The support for SET operations in a non-secure environment without proper protection can have a negative effect on network operations. SNMPv1 by itself is not a secure environment. Even if the network itself is secure (for example by using IPSec), even then, there is no control as to who on the secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB. It is recommended that the implementers consider the security features as provided by the SNMPv3 framework. Specifically, the use of the User-based Security Model RFC 2574 [12] and the View-based Access Control Model RFC 2575 [15] is recommended. Teow Standards Track [Page 43]
RFC 2837 FC Fabric Element MIB May 2000 It is then a customer/user responsibility to ensure that the SNMP entity giving access to an instance of this MIB, is properly configured to give access to the objects only to those principals (users) that have legitimate rights to indeed GET or SET (change/delete) them. 5. Intellectual Property The IETF takes no position regarding the validity or scope of any intellectual property or other rights that might be claimed to pertain to the implementation or use of the technology described in this document or the extent to which any license under such rights might or might not be available; neither does it represent that it has made any effort to identify any such rights. Information on the IETF's procedures with respect to rights in standards-track and standards-related documentation can be found in BCP-11. Copies of claims of rights made available for publication and any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementors or users of this specification can be obtained from the IETF Secretariat. The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights which may cover technology that may be required to practice this standard. Please address the information to the IETF Executive Director. 6. Acknowledgements The editors would like to thank the following individuals for their assistance and constructive comments: Juergen Schoenwaelder, Technical University Braunschweig Vincent Guan, Brocade Gavin Bowlby, Gadzoox Bent Stoevhase, Brocade Jeff Meyer, HP John Y. Chu, IBM Yakov Rekhter, Cisco Martin Sachs, IBM Dan Eisenhauer, IBM Beth Vanderbeck, IBM Carl Zeitler, Compaq Paul Griffiths, IBM KC Chennappan, IBM Jessie Haug, IBM Bob Cornelius, ANCOR Lansing Sloan, LLNL Paul Rupert, LLNL Rich Taborak, NSerial Steve Wilson, Brocade Jerry Rouse, IBM Dal Allan, ENDL Hubert Huot, IBM Venkat Rao, HP Amir Artsi, RADWAY International Ltd. Teow Standards Track [Page 44]
RFC 2837 FC Fabric Element MIB May 2000 7. References 7.1. IETF References [1] Harrington, D., Presuhn, R. and B. Wijnen, "An Architecture for Describing SNMP Management Frameworks", RFC 2571, April 1999. [2] Rose, M. and K. McCloghrie, "Structure and Identification of Management Information for TCP/IP-based Internets", STD 16, RFC 1155, May 1990. [3] Rose, M. and K. McCloghrie, "Concise MIB Definitions", STD 16, RFC 1212, March 1991. [4] Rose, M., "A Convention for Defining Traps for use with the SNMP", RFC 1215, March 1991. [5] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M. and S. Waldbusser, "Structure of Management Information Version 2 (SMIv2)", STD 58, RFC 2578, April 1999. [6] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M. and S. Waldbusser, "Textual Conventions for SMIv2", STD 58, RFC 2579, April 1999. [7] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M. and S. Waldbusser, "Conformance Statements for SMIv2", STD 58, RFC 2580, April 1999. [8] Case, J., Fedor, M., Schoffstall, M. and J. Davin, "Simple Network Management Protocol", STD 15, RFC 1157, May 1990. [9] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Introduction to Community-based SNMPv2", RFC 1901, January 1996. [10] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Transport Mappings for Version 2 of the Simple Network Management Protocol (SNMPv2)", RFC 1906, January 1996. [11] Case, J., Harrington D., Presuhn R. and B. Wijnen, "Message Processing and Dispatching for the Simple Network Management Protocol (SNMP)", RFC 2572, April 1999. [12] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)", RFC 2574, April 1999. Teow Standards Track [Page 45]
RFC 2837 FC Fabric Element MIB May 2000 [13] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Protocol Operations for Version 2 of the Simple Network Management Protocol (SNMPv2)", RFC 1905, January 1996. [14] Levi, D., Meyer, P. and B. Stewart, "SNMPv3 Applications", RFC 2573, April 1999. [15] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP)", RFC 2575, April 1999. [16] Case, J., Mundy, R., Partain, D. and B. Stewart, "Introduction to Version 3 of the Internet-standard Network Management Framework", RFC 2570, April 1999. 7.2. Approved ANSI/NCITS References [17] Fibre Channel Physical and Signaling Interface (FC-PH), American National Standard for Information Systems X3.230:1994, Computer and Business Equipment Manufacturers Association, Washington, DC. [18] Fibre Channel Fabric Generic (FC-FG), American National Standard for Information Systems X3.289:1996, Computer and Business Equipment Manufacturers Association, Washington, DC. [19] Fibre Channel Generic Services (FC-GS), American National Standard for Information Systems X3.288:1996, Computer and Business Equipment Manufacturers Association, Washington, DC. [20] Fibre Channel Arbitrated Loop (FC-AL), American National Standard for Information Systems X3.272:1996, Computer and Business Equipment Manufacturers Association, Washington, DC. [21] Fibre Channel Physical and Signaling Interface-2 (FC-PH-2), American National Standard for Information Systems, X3.297:1997, Computer and Business Equipment Manufacturers Association, Washington, DC. [22] Fibre Channel Physical and Signaling Interface-3 (FC-PH-3), American National Standard for Information Systems, X3.303:1998, Computer and Business Equipment Manufacturers Association, Washington, DC. [23] Fibre Channel Switch Fabric (FC-SW), American National Standard for Information Systems, NCITS 321:1998, Computer and Business Equipment Manufacturers Association, Washington, DC. Teow Standards Track [Page 46]
RFC 2837 FC Fabric Element MIB May 2000 7.3. ANSI/NCITS References Under Development [24] Fibre Channel Arbitrated Loop-2 (FC-AL-2), American National Standard for Information Systems, X3T11/1133D Rev 5.2, Computer and Business Equipment Manufacturers Association, Washington, DC. 8. Editor's Address Kha Sin Teow Brocade Communications Systems, Inc. 1901 Guadalupe Parkway, San Jose, CA 95131 U.S.A. Phone: +1 408-487-8180 Email: khasin@Brocade.COM Teow Standards Track [Page 47]
RFC 2837 FC Fabric Element MIB May 2000 9. Full Copyright Statement Copyright (C) The Internet Society (2000). All Rights Reserved. This document and translations of it may be copied and furnished to others, and derivative works that comment on or otherwise explain it or assist in its implementation may be prepared, copied, published and distributed, in whole or in part, without restriction of any kind, provided that the above copyright notice and this paragraph are included on all such copies and derivative works. However, this document itself may not be modified in any way, such as by removing the copyright notice or references to the Internet Society or other Internet organizations, except as needed for the purpose of developing Internet standards in which case the procedures for copyrights defined in the Internet Standards process must be followed, or as required to translate it into languages other than English. The limited permissions granted above are perpetual and will not be revoked by the Internet Society or its successors or assigns. This document and the information contained herein is provided on an "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Acknowledgement Funding for the RFC Editor function is currently provided by the Internet Society. Teow Standards Track [Page 48]