Network Working Group                                         A. Bierman
Request for Comments: 3434                                 K. McCloghrie
Category:Standards Track                             Cisco Systems, Inc.
                                                           December 2002


                  Remote Monitoring MIB Extensions for
                          High Capacity Alarms

Status of this Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (2002).  All Rights Reserved.

Abstract

   This memo defines a portion of the Management Information Base (MIB)
   for use with network management protocols in the Internet community.
   In particular, it describes managed objects for extending the alarm
   thresholding capabilities found in the Remote Monitoring (RMON) MIB
   (RFC 2819), to provide similar threshold monitoring of objects based
   on the Counter64 data type.

Table of Contents

   1 The Internet-Standard Management Framework ...................    2
   2 Terms ........................................................    2
   3 Overview .....................................................    2
     3.1 Relationship to the Remote Monitoring MIBs ...............    3
   4 MIB Structure ................................................    4
     4.1 MIB Group Overview .......................................    4
         4.1.1 High Capacity Alarm Control Group ..................    5
         4.1.2 High Capacity Alarm Capabilities ...................    6
         4.1.3 High Capacity Alarm Notifications ..................    6
   5 Definitions ..................................................    6
   6 Intellectual Property ........................................   21
   7 Acknowledgements .............................................   21
   8 Normative References .........................................   21
   9 Informative References .......................................   22





Bierman & McCloghrie        Standards Track                     [Page 1]


RFC 3434                High Capacity Alarm MIB            December 2002


   10 Security Considerations .....................................   22
   11 Authors' Addresses ..........................................   23
   12 Full Copyright Statement ....................................   24

1. The Internet-Standard Management Framework

   For a detailed overview of the documents that describe the current
   Internet-Standard Management Framework, please refer to section 7 of
   RFC 3410 [RFC3410].

   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB.  MIB objects are generally
   accessed through the Simple Network Management Protocol (SNMP).
   Objects in the MIB are defined using the mechanisms defined in the
   Structure of Management Information (SMI).  This memo specifies a MIB
   module that is compliant to the SMIv2, which is described in STD 58,
   RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
   [RFC2580].

2.  Terms

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED",  "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in BCP 14, RFC 2119.
   [RFC2119]

3.  Overview

   There is a need for a standardized way of providing the same type of
   alarm thresholding capabilities for Counter64 objects, as already
   exists for Counter32 objects.  The RMON-1 alarmTable objects and
   RMON-1 notification types are specific to 32-bit objects, and cannot
   be used to properly monitor Counter64-based objects.  Extensions to
   these existing constructs which explicitly support Counter64-based
   objects are needed.  These extensions are completely independent of
   the existing RMON-1 alarm mechanisms.

   The usage of Counter64 objects is increasing.  One of the causes for
   this increase is the increasing speeds of network interfaces; RFC
   2863 [RFC2863] says:

      As the speed of network media increase, the minimum time in which
      a 32 bit counter will wrap decreases.  For example, a 10Mbs stream
      of back-to-back, full-size packets causes ifInOctets to wrap in
      just over 57 minutes; at 100Mbs, the minimum wrap time is 5.7
      minutes, and at 1Gbs, the minimum is 34 seconds.  Requiring that
      interfaces be polled frequently enough not to miss a counter wrap
      is increasingly problematic.



Bierman & McCloghrie        Standards Track                     [Page 2]


RFC 3434                High Capacity Alarm MIB            December 2002


   and therefore requires:

      For interfaces that operate at 20,000,000 (20 million) bits per
      second or less, 32-bit byte and packet counters MUST be supported.
      For interfaces that operate faster than 20,000,000 bits/second,
      and slower than 650,000,000 bits/second, 32-bit packet counters
      MUST be supported and 64-bit octet counters MUST be supported.
      For interfaces that operate at 650,000,000 bits/second or faster,
      64-bit packet counters AND 64-bit octet counters MUST be
      supported.

   Of the variables on which thresholds are set using RMON-1's
   alarmTable, two of the most popular are: ifInOctets and ifOutOctets.
   Thus, the increasing usage of the 64-bit versions: ifHCInOctets and
   ifHCOutOctets means that there is an increasing requirement to use
   RMON-1's thresholding capability for ifHCInOctets and ifHCOutOctets.

   The RMON-1 Alarm Group is implemented not only by all RMON probes,
   but also by the SNMP agents in many other types of devices for the
   purpose of monitoring any of their (non-RMON) integer-valued MIB
   objects.  The fact that it has been so widely implemented indicates
   its obvious value.  Without this extension, that obvious value is
   becoming incomplete because of its lack of support for 64-bit
   integers.  This extension is the easiest, simplest, and most
   compatible way for an implementation to overcome that lack of
   support.

3.1.  Relationship to the Remote Monitoring MIBs

   This MIB is intended to be implemented in Remote Monitoring (RMON)
   probes, which may also support the RMON-1 MIB [RFC2819].  Such probes
   may be stand-alone devices, or may be co-located with other
   networking devices (e.g., ethernet switches and repeaters).

   The functionality of the High Capacity Alarm Group is a superset of
   RMON-1's Alarm Group.  Thus, one day in the distant future, it is a
   possibility that RMON-1's Alarm Group will be deprecated in favor of
   this MIB's High Capacity Alarm Group.  However, that day will not
   come before this document, or one of its successors, reaches the same
   standardization state as RMON-1.











Bierman & McCloghrie        Standards Track                     [Page 3]


RFC 3434                High Capacity Alarm MIB            December 2002


4.  MIB Structure

        Figure 1: HC-ALARM MIB Functional Structure

    +---------------------------------------------+
    |                                             |
    |     (RMON-1)              (HC-ALARM)        |
    |   +-----------+          +-----------+      |
    |   |           |          |           |      |
    |   |   alarm   |          |  hcAlarm  |      |
    |   |   Table   |          |  Table    |      |
    |   |           |          |           |      |
    |   +-----------+          +-----------+      |
    |         |                      |            |
    |         V      (RMON-1)        V            |
    |   +----------------------------------+      |
    |   |                                  |      |
    |   |            eventTable            |      |
    |   |                                  |      |
    |   +----------------------------------+      |
    |         |                      |            |
    |         |                      |            |
    |         V                      V            |
    |   +---------------+    +----------------+   |
    |   | risingAlarm   |    | hcRisingAlarm  |   |
    |   | fallingAlarm  |    | hcFallingAlarm |   |
    |   | Notifications |    | Notifications  |   |
    |   +---------------+    +----------------+   |
    |       (RMON-1)             (HC-ALARM)       |
    +---------------------------------------------+

4.1.  MIB Group Overview

   The HC-ALARM MIB contains three MIB groups:

     - hcAlarmControlObjects group
        Controls the configuration of alarms for high capacity MIB
        object instances.

     - hcAlarmCapabilities group
        Describes the high capacity alarm capabilities provided by the
        agent.

     - hcAlarmNotifications group
        Provide new rising and falling threshold notifications for high
        capacity objects.





Bierman & McCloghrie        Standards Track                     [Page 4]


RFC 3434                High Capacity Alarm MIB            December 2002


4.1.1.  High Capacity Alarm Control Group

   This group contains one table, which is used by a management station
   to configure high capacity alarm entries.  To configure alarm
   thresholding for Counter64 or CounterBasedGauge64 objects, a
   management application must configure the hcAlarmTable in a manner
   similar to how RMON-1's alarmTable is configured.

   Because the language in some of the DESCRIPTION clauses of objects in
   the alarmTable is specific to the alarmTable itself, their defined
   semantics do not allow them to be used for this MIB also.  Therefore,
   the following objects are essentially cloned from the alarmTable to
   the hcAlarmTable:

       alarmTable                 hcAlarmTable
       ----------                 ------------
       alarmIndex                 hcAlarmIndex
       alarmInterval              hcAlarmInterval
       alarmVariable              hcAlarmVariable
       alarmSampleType            hcAlarmSampleType
       alarmStartupAlarm          hcAlarmStartupAlarm
       alarmRisingEventIndex      hcAlarmRisingEventIndex
       alarmFallingEventIndex     hcAlarmFallingEventIndex
       alarmOwner                 hcAlarmOwner
       alarmStatus                hcAlarmStatus

   In addition, the following hcAlarmTable objects are used as high
   capacity values instead of the corresponding 32-bit version in the
   alarmTable.

       alarmTable                 hcAlarmTable
       ----------                 ------------
       alarmValue                 hcAlarmAbsValue
                                  hcAlarmValueStatus
       alarmRisingThreshold       hcAlarmRisingThreshAbsValueLo
                                  hcAlarmRisingThreshAbsValueHi
                                  hcAlarmRisingThresholdValStatus
       alarmFallingThreshold      hcAlarmFallingThreshAbsValueLo
                                  hcAlarmFallingThreshAbsValueHi
                                  hcAlarmFallingThresholdValStatus

   Nevertheless, the hcAlarmTable does have a few differences from the
   alarmTable:

      - Counter64 based objects are thresholded properly
      - an entry is not destroyed if the instance identified by the
        hcAlarmVariable is not available during a polling interval.




Bierman & McCloghrie        Standards Track                     [Page 5]


RFC 3434                High Capacity Alarm MIB            December 2002


      - the RowStatus textual convention is used instead of EntryStatus
        for the hcAlarmStatus object.
      - the non-volatile storage of an HC alarm entry is explicitly
        controlled with a StorageType parameter.
      - a counter is provided to indicate the number of times the
        hcAlarmVariable object value could not be retrieved by the
        agent.

4.1.2.  High Capacity Alarm Capabilities

   This group contains a single scalar object, called
   hcAlarmCapabilities.  It describes the basic high capacity alarm
   features supported by the agent.

4.1.3.  High Capacity Alarm Notifications

   This group contains two notifications, hcRisingAlarm and
   hcFallingAlarm.  These are generated for high capacity alarms in the
   same manner and used to convey essentially the same information as
   RMON-1's risingAlarm and fallingAlarm notifications do for
   alarmTable-specified alarms.

5.  Definitions

HC-ALARM-MIB DEFINITIONS ::= BEGIN

IMPORTS
        MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
        Integer32, Counter32, Unsigned32
                FROM SNMPv2-SMI
        MODULE-COMPLIANCE, OBJECT-GROUP,
        NOTIFICATION-GROUP
                FROM SNMPv2-CONF
        RowStatus, VariablePointer, StorageType,
        TEXTUAL-CONVENTION
                FROM SNMPv2-TC
        CounterBasedGauge64
                FROM HCNUM-TC
        rmon, OwnerString, rmonEventGroup
                FROM RMON-MIB;

hcAlarmMIB MODULE-IDENTITY
    LAST-UPDATED    "200212160000Z"
    ORGANIZATION    "IETF RMONMIB Working Group"
    CONTACT-INFO
            "        Andy Bierman
                     Cisco Systems, Inc.
                Tel: +1 408 527-3711



Bierman & McCloghrie        Standards Track                     [Page 6]


RFC 3434                High Capacity Alarm MIB            December 2002


             E-mail: abierman@cisco.com
             Postal: 170 West Tasman Drive
                     San Jose, CA USA 95134

                     Keith McCloghrie
                     Cisco Systems, Inc.
                Tel: +1 408 526-5260
             E-mail: kzm@cisco.com
             Postal: 170 West Tasman Drive
                     San Jose, CA USA 95134

             Send comments to <rmonmib@ietf.org>
             Mailing list subscription info:
                 http://www.ietf.org/mailman/listinfo/rmonmib "
    DESCRIPTION
            "This module defines Remote Monitoring MIB extensions for
             High Capacity Alarms.

             Copyright (C) The Internet Society (2002). This version
             of this MIB module is part of RFC 3434; see the RFC
             itself for full legal notices."

    REVISION        "200212160000Z"
    DESCRIPTION
            "Initial version of the High Capacity Alarm MIB module.
             This version published as RFC 3434."
    ::= { rmon 29 }

hcAlarmObjects       OBJECT IDENTIFIER ::= { hcAlarmMIB 1 }
hcAlarmNotifications OBJECT IDENTIFIER ::= { hcAlarmMIB 2 }
hcAlarmConformance   OBJECT IDENTIFIER ::= { hcAlarmMIB 3 }

hcAlarmControlObjects OBJECT IDENTIFIER ::= { hcAlarmObjects 1 }
hcAlarmCapabilitiesObjects OBJECT IDENTIFIER
                                        ::= { hcAlarmObjects 2 }

--
-- Textual Conventions
--

HcValueStatus ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
            "This data type indicates the validity and sign of the data
            in associated object instances which represent the absolute
            value of a high capacity numeric quantity.  Such an object
            may be represented with one or more object instances. An
            object of type HcValueStatus MUST be defined within the same



Bierman & McCloghrie        Standards Track                     [Page 7]


RFC 3434                High Capacity Alarm MIB            December 2002


            structure as the object(s) representing the high capacity
            absolute value.

            If the associated object instance(s) representing the high
            capacity absolute value could not be accessed during the
            sampling interval, and is therefore invalid, then the
            associated HcValueStatus object will contain the value
            'valueNotAvailable(1)'.

            If the associated object instance(s) representing the high
            capacity absolute value are valid and actual value of the
            sample is greater than or equal to zero, then the associated
            HcValueStatus object will contain the value
            'valuePositive(2)'.

            If the associated object instance(s) representing the high
            capacity absolute value are valid and the actual value of
            the sample is less than zero, then the associated
            HcValueStatus object will contain the value
            'valueNegative(3)'.  The associated absolute value should be
            multiplied by -1 to obtain the true sample value."
    SYNTAX INTEGER {
        valueNotAvailable(1),
        valuePositive(2),
        valueNegative(3)
    }

--
-- High Capacity Alarm Table
--

hcAlarmTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF HcAlarmEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "A list of entries for the configuration of high capacity
            alarms."
    ::= { hcAlarmControlObjects 1 }

hcAlarmEntry OBJECT-TYPE
    SYNTAX      HcAlarmEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "A conceptual row in the hcAlarmTable. Entries are usually
            created in this table by management application action, but
            may also be created by agent action as well."



Bierman & McCloghrie        Standards Track                     [Page 8]


RFC 3434                High Capacity Alarm MIB            December 2002


    INDEX { hcAlarmIndex }
    ::= { hcAlarmTable 1 }

HcAlarmEntry ::= SEQUENCE {
    hcAlarmIndex                     Integer32,
    hcAlarmInterval                  Integer32,
    hcAlarmVariable                  VariablePointer,
    hcAlarmSampleType                INTEGER,
    hcAlarmAbsValue                  CounterBasedGauge64,
    hcAlarmValueStatus               HcValueStatus,
    hcAlarmStartupAlarm              INTEGER,
    hcAlarmRisingThreshAbsValueLo    Unsigned32,
    hcAlarmRisingThreshAbsValueHi    Unsigned32,
    hcAlarmRisingThresholdValStatus  HcValueStatus,
    hcAlarmFallingThreshAbsValueLo   Unsigned32,
    hcAlarmFallingThreshAbsValueHi   Unsigned32,
    hcAlarmFallingThresholdValStatus HcValueStatus,
    hcAlarmRisingEventIndex          Integer32,
    hcAlarmFallingEventIndex         Integer32,
    hcAlarmValueFailedAttempts       Counter32,
    hcAlarmOwner                     OwnerString,
    hcAlarmStorageType               StorageType,
    hcAlarmStatus                    RowStatus }

hcAlarmIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..65535)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "An arbitrary integer index value used to uniquely identify
            this high capacity alarm entry."
    ::= { hcAlarmEntry 1 }

hcAlarmInterval OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    UNITS      "seconds"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
            "The interval in seconds over which the data is sampled and
            compared with the rising and falling thresholds.  When
            setting this variable, care should be taken in the case of
            deltaValue sampling - the interval should be set short
            enough that the sampled variable is very unlikely to
            increase or decrease by more than 2^63 - 1 during a single
            sampling interval.





Bierman & McCloghrie        Standards Track                     [Page 9]


RFC 3434                High Capacity Alarm MIB            December 2002


            This object may not be modified if the associated
            hcAlarmStatus object is equal to active(1)."
    ::= { hcAlarmEntry 2 }

hcAlarmVariable OBJECT-TYPE
    SYNTAX      VariablePointer
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
            "The object identifier of the particular variable to be
            sampled.  Only variables that resolve to an ASN.1 primitive
            type of INTEGER (INTEGER, Integer32, Counter32, Counter64,
            Gauge, or TimeTicks) may be sampled.

            Because SNMP access control is articulated entirely in terms
            of the contents of MIB views, no access control mechanism
            exists that can restrict the value of this object to
            identify only those objects that exist in a particular MIB
            view.  Because there is thus no acceptable means of
            restricting the read access that could be obtained through
            the alarm mechanism, the probe must only grant write access
            to this object in those views that have read access to all
            objects on the probe.

            This object may not be modified if the associated
            hcAlarmStatus object is equal to active(1)."
    ::= { hcAlarmEntry 3 }

hcAlarmSampleType OBJECT-TYPE
    SYNTAX INTEGER {
               absoluteValue(1),
               deltaValue(2)
           }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
            "The method of sampling the selected variable and
            calculating the value to be compared against the thresholds.
            If the value of this object is absoluteValue(1), the value
            of the selected variable will be compared directly with the
            thresholds at the end of the sampling interval.  If the
            value of this object is deltaValue(2), the value of the
            selected variable at the last sample will be subtracted from
            the current value, and the difference compared with the
            thresholds.

            If the associated hcAlarmVariable instance could not be
            obtained at the previous sample interval, then a delta



Bierman & McCloghrie        Standards Track                    [Page 10]


RFC 3434                High Capacity Alarm MIB            December 2002


            sample is not possible, and the value of the associated
            hcAlarmValueStatus object for this interval will be
            valueNotAvailable(1).

            This object may not be modified if the associated
            hcAlarmStatus object is equal to active(1)."
    ::= { hcAlarmEntry 4 }

hcAlarmAbsValue OBJECT-TYPE
    SYNTAX      CounterBasedGauge64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The absolute value (i.e., unsigned value) of the
            hcAlarmVariable statistic during the last sampling period.
            The value during the current sampling period is not made
            available until the period is completed.

            To obtain the true value for this sampling interval, the
            associated instance of hcAlarmValueStatus must be checked,
            and the value of this object adjusted as necessary.

            If the MIB instance could not be accessed during the
            sampling interval, then this object will have a value of
            zero and the associated instance of hcAlarmValueStatus will
            be set to 'valueNotAvailable(1)'."
    ::= { hcAlarmEntry 5 }

hcAlarmValueStatus OBJECT-TYPE
    SYNTAX      HcValueStatus
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "This object indicates the validity and sign of the data for
            the hcAlarmAbsValue object, as described in the
            HcValueStatus textual convention."
    ::= { hcAlarmEntry 6 }

hcAlarmStartupAlarm OBJECT-TYPE
    SYNTAX     INTEGER {
                  risingAlarm(1),
                  fallingAlarm(2),
                  risingOrFallingAlarm(3)
               }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
            "The alarm that may be sent when this entry is first set to



Bierman & McCloghrie        Standards Track                    [Page 11]


RFC 3434                High Capacity Alarm MIB            December 2002


            active.  If the first sample after this entry becomes active
            is greater than or equal to the rising threshold and this
            object is equal to risingAlarm(1) or
            risingOrFallingAlarm(3), then a single rising alarm will be
            generated.  If the first sample after this entry becomes
            valid is less than or equal to the falling threshold and
            this object is equal to fallingAlarm(2) or
            risingOrFallingAlarm(3), then a single falling alarm will be
            generated.

            This object may not be modified if the associated
            hcAlarmStatus object is equal to active(1)."
    ::= { hcAlarmEntry 7 }

hcAlarmRisingThreshAbsValueLo OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
            "The lower 32 bits of the absolute value for threshold for
            the sampled statistic.  The actual threshold value is
            determined by the associated instances of the
            hcAlarmRisingThreshAbsValueHi and
            hcAlarmRisingThresholdValStatus objects, as follows:

               ABS(threshold) = hcAlarmRisingThreshAbsValueLo +
                     (hcAlarmRisingThreshAbsValueHi * 2^^32)

            The absolute value of the threshold is adjusted as required,
            as described in the HcValueStatus textual convention.  These
            three object instances are conceptually combined to
            represent the rising threshold for this entry.

            When the current sampled value is greater than or equal to
            this threshold, and the value at the last sampling interval
            was less than this threshold, a single event will be
            generated.  A single event will also be generated if the
            first sample after this entry becomes valid is greater than
            or equal to this threshold and the associated
            hcAlarmStartupAlarm is equal to risingAlarm(1) or
            risingOrFallingAlarm(3).

            After a rising event is generated, another such event will
            not be generated until the sampled value falls below this
            threshold and reaches the threshold identified by the
            hcAlarmFallingThreshAbsValueLo,
            hcAlarmFallingThreshAbsValueHi, and
            hcAlarmFallingThresholdValStatus objects.



Bierman & McCloghrie        Standards Track                    [Page 12]


RFC 3434                High Capacity Alarm MIB            December 2002


            This object may not be modified if the associated
            hcAlarmStatus object is equal to active(1)."

    ::= { hcAlarmEntry 8 }

hcAlarmRisingThreshAbsValueHi OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
            "The upper 32 bits of the absolute value for threshold for
            the sampled statistic.  The actual threshold value is
            determined by the associated instances of the
            hcAlarmRisingThreshAbsValueLo and
            hcAlarmRisingThresholdValStatus objects, as follows:

               ABS(threshold) = hcAlarmRisingThreshAbsValueLo +
                     (hcAlarmRisingThreshAbsValueHi * 2^^32)

            The absolute value of the threshold is adjusted as required,
            as described in the HcValueStatus textual convention.  These
            three object instances are conceptually combined to
            represent the rising threshold for this entry.

            When the current sampled value is greater than or equal to
            this threshold, and the value at the last sampling interval
            was less than this threshold, a single event will be
            generated.  A single event will also be generated if the
            first sample after this entry becomes valid is greater than
            or equal to this threshold and the associated
            hcAlarmStartupAlarm is equal to risingAlarm(1) or
            risingOrFallingAlarm(3).

            After a rising event is generated, another such event will
            not be generated until the sampled value falls below this
            threshold and reaches the threshold identified by the
            hcAlarmFallingThreshAbsValueLo,
            hcAlarmFallingThreshAbsValueHi, and
            hcAlarmFallingThresholdValStatus objects.

            This object may not be modified if the associated
            hcAlarmStatus object is equal to active(1)."
    ::= { hcAlarmEntry 9 }

hcAlarmRisingThresholdValStatus OBJECT-TYPE
    SYNTAX      HcValueStatus
    MAX-ACCESS  read-create
    STATUS      current



Bierman & McCloghrie        Standards Track                    [Page 13]


RFC 3434                High Capacity Alarm MIB            December 2002


    DESCRIPTION
            "This object indicates the sign of the data for the rising
            threshold, as defined by the hcAlarmRisingThresAbsValueLo
            and hcAlarmRisingThresAbsValueHi objects, as described in
            the HcValueStatus textual convention.

            The enumeration 'valueNotAvailable(1)' is not allowed, and
            the associated hcAlarmStatus object cannot be equal to
            'active(1)' if this object is set to this value.

            This object may not be modified if the associated
            hcAlarmStatus object is equal to active(1)."
    ::= { hcAlarmEntry 10 }

hcAlarmFallingThreshAbsValueLo OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
            "The lower 32 bits of the absolute value for threshold for
            the sampled statistic.  The actual threshold value is
            determined by the associated instances of the
            hcAlarmFallingThreshAbsValueHi and
            hcAlarmFallingThresholdValStatus objects, as follows:

               ABS(threshold) = hcAlarmFallingThreshAbsValueLo +
                     (hcAlarmFallingThreshAbsValueHi * 2^^32)

            The absolute value of the threshold is adjusted as required,
            as described in the HcValueStatus textual convention.  These
            three object instances are conceptually combined to
            represent the falling threshold for this entry.

            When the current sampled value is less than or equal to this
            threshold, and the value at the last sampling interval was
            greater than this threshold, a single event will be
            generated.  A single event will also be generated if the
            first sample after this entry becomes valid is less than or
            equal to this threshold and the associated
            hcAlarmStartupAlarm is equal to fallingAlarm(2) or
            risingOrFallingAlarm(3).

            After a falling event is generated, another such event will
            not be generated until the sampled value rises above this
            threshold and reaches the threshold identified by the
            hcAlarmRisingThreshAbsValueLo,
            hcAlarmRisingThreshAbsValueHi, and
            hcAlarmRisingThresholdValStatus objects.



Bierman & McCloghrie        Standards Track                    [Page 14]


RFC 3434                High Capacity Alarm MIB            December 2002


            This object may not be modified if the associated
            hcAlarmStatus object is equal to active(1)."
    ::= { hcAlarmEntry 11 }

hcAlarmFallingThreshAbsValueHi OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
            "The upper 32 bits of the absolute value for threshold for
            the sampled statistic.  The actual threshold value is
            determined by the associated instances of the
            hcAlarmFallingThreshAbsValueLo and
            hcAlarmFallingThresholdValStatus objects, as follows:

               ABS(threshold) = hcAlarmFallingThreshAbsValueLo +
                     (hcAlarmFallingThreshAbsValueHi * 2^^32)

            The absolute value of the threshold is adjusted as required,
            as described in the HcValueStatus textual convention.  These
            three object instances are conceptually combined to
            represent the falling threshold for this entry.

            When the current sampled value is less than or equal to this
            threshold, and the value at the last sampling interval was
            greater than this threshold, a single event will be
            generated.  A single event will also be generated if the
            first sample after this entry becomes valid is less than or
            equal to this threshold and the associated
            hcAlarmStartupAlarm is equal to fallingAlarm(2) or
            risingOrFallingAlarm(3).

            After a falling event is generated, another such event will
            not be generated until the sampled value rises above this
            threshold and reaches the threshold identified by the
            hcAlarmRisingThreshAbsValueLo,
            hcAlarmRisingThreshAbsValueHi, and
            hcAlarmRisingThresholdValStatus objects.

            This object may not be modified if the associated
            hcAlarmStatus object is equal to active(1)."
    ::= { hcAlarmEntry 12 }

hcAlarmFallingThresholdValStatus OBJECT-TYPE
    SYNTAX      HcValueStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION



Bierman & McCloghrie        Standards Track                    [Page 15]


RFC 3434                High Capacity Alarm MIB            December 2002


            "This object indicates the sign of the data for the falling
            threshold, as defined by the hcAlarmFallingThreshAbsValueLo
            and hcAlarmFallingThreshAbsValueHi objects, as described in
            the HcValueStatus textual convention.

            The enumeration 'valueNotAvailable(1)' is not allowed, and
            the associated hcAlarmStatus object cannot be equal to
            'active(1)' if this object is set to this value.

            This object may not be modified if the associated
            hcAlarmStatus object is equal to active(1)."
    ::= { hcAlarmEntry 13 }

hcAlarmRisingEventIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
            "The index of the eventEntry that is used when a rising
            threshold is crossed.  The eventEntry identified by a
            particular value of this index is the same as identified by
            the same value of the eventIndex object.  If there is no
            corresponding entry in the eventTable, then no association
            exists.  In particular, if this value is zero, no associated
            event will be generated, as zero is not a valid event index.

            This object may not be modified if the associated
            hcAlarmStatus object is equal to active(1)."
    ::= { hcAlarmEntry 14 }

hcAlarmFallingEventIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
            "The index of the eventEntry that is used when a falling
            threshold is crossed.  The eventEntry identified by a
            particular value of this index is the same as identified by
            the same value of the eventIndex object.  If there is no
            corresponding entry in the eventTable, then no association
            exists.  In particular, if this value is zero, no associated
            event will be generated, as zero is not a valid event index.

            This object may not be modified if the associated
            hcAlarmStatus object is equal to active(1)."
    ::= { hcAlarmEntry 15 }

hcAlarmValueFailedAttempts OBJECT-TYPE



Bierman & McCloghrie        Standards Track                    [Page 16]


RFC 3434                High Capacity Alarm MIB            December 2002


    SYNTAX     Counter32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The number of times the associated hcAlarmVariable instance
            was polled on behalf of this hcAlarmEntry, (while in the
            active state) and the value was not available.  This counter
            may experience a discontinuity if the agent restarts,
            indicated by the value of sysUpTime."
    ::= { hcAlarmEntry 16 }

hcAlarmOwner OBJECT-TYPE
    SYNTAX     OwnerString
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
            "The entity that configured this entry and is therefore
            using the resources assigned to it."
    ::= { hcAlarmEntry 17 }

hcAlarmStorageType OBJECT-TYPE
    SYNTAX     StorageType
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
            "The type of non-volatile storage configured for this entry.
            If this object is equal to 'permanent(4)', then the
            associated hcAlarmRisingEventIndex and
            hcAlarmFallingEventIndex objects must be writable."
    ::= { hcAlarmEntry 18 }

hcAlarmStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
            "The status of this row.

            An entry MUST NOT exist in the active state unless all
            objects in the entry have an appropriate value, as described
            in the description clause for each writable object.

            The hcAlarmStatus object may be modified if the associated
            instance of this object is equal to active(1),
            notInService(2), or notReady(3).  All other writable objects
            may be modified if the associated instance of this object is
            equal to notInService(2) or notReady(3)."
    ::= { hcAlarmEntry 19 }



Bierman & McCloghrie        Standards Track                    [Page 17]


RFC 3434                High Capacity Alarm MIB            December 2002


--
-- Capabilities
--

hcAlarmCapabilities OBJECT-TYPE
    SYNTAX      BITS {
       hcAlarmCreation(0),
       hcAlarmNvStorage(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "An indication of the high capacity alarm capabilities
            supported by this agent.

            If the 'hcAlarmCreation' BIT is set, then this agent allows
            NMS applications to create entries in the hcAlarmTable.

            If the 'hcAlarmNvStorage' BIT is set, then this agent allows
            entries in the hcAlarmTable which will be recreated after a
            system restart, as controlled by the hcAlarmStorageType
            object."
    ::= { hcAlarmCapabilitiesObjects 1 }

--
-- Notifications
--

hcAlarmNotifPrefix OBJECT IDENTIFIER
      ::= { hcAlarmNotifications 0 }

hcRisingAlarm NOTIFICATION-TYPE
    OBJECTS  { hcAlarmVariable,
               hcAlarmSampleType,
               hcAlarmAbsValue,
               hcAlarmValueStatus,
               hcAlarmRisingThreshAbsValueLo,
               hcAlarmRisingThreshAbsValueHi,
               hcAlarmRisingThresholdValStatus,
               hcAlarmRisingEventIndex }
    STATUS   current
    DESCRIPTION
            "The SNMP notification that is generated when a high
            capacity alarm entry crosses its rising threshold and
            generates an event that is configured for sending SNMP
            traps.

            The hcAlarmEntry object instances identified in the OBJECTS



Bierman & McCloghrie        Standards Track                    [Page 18]


RFC 3434                High Capacity Alarm MIB            December 2002


            clause are from the entry that causes this notification to
            be generated."
     ::= { hcAlarmNotifPrefix 1 }

hcFallingAlarm NOTIFICATION-TYPE
    OBJECTS { hcAlarmVariable,
              hcAlarmSampleType,
              hcAlarmAbsValue,
              hcAlarmValueStatus,
              hcAlarmFallingThreshAbsValueLo,
              hcAlarmFallingThreshAbsValueHi,
              hcAlarmFallingThresholdValStatus,
              hcAlarmFallingEventIndex }
    STATUS    current
    DESCRIPTION
            "The SNMP notification that is generated when a high
            capacity alarm entry crosses its falling threshold and
            generates an event that is configured for sending SNMP
            traps.

            The hcAlarmEntry object instances identified in the OBJECTS
            clause are from the entry that causes this notification to
            be generated."
     ::= { hcAlarmNotifPrefix 2 }

--
-- Conformance Section
--

hcAlarmCompliances OBJECT IDENTIFIER ::= { hcAlarmConformance 1 }
hcAlarmGroups      OBJECT IDENTIFIER ::= { hcAlarmConformance 2 }

hcAlarmCompliance MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
            "Describes the requirements for conformance to the High
            Capacity Alarm MIB."
    MODULE  -- this module
        MANDATORY-GROUPS {
                           hcAlarmControlGroup,
                           hcAlarmCapabilitiesGroup,
                           hcAlarmNotificationsGroup
                         }

    MODULE RMON-MIB
        MANDATORY-GROUPS { rmonEventGroup }

    ::= { hcAlarmCompliances 1 }



Bierman & McCloghrie        Standards Track                    [Page 19]


RFC 3434                High Capacity Alarm MIB            December 2002


-- Object Groups

hcAlarmControlGroup OBJECT-GROUP
    OBJECTS {
             hcAlarmInterval,
             hcAlarmVariable,
             hcAlarmSampleType,
             hcAlarmAbsValue,
             hcAlarmValueStatus,
             hcAlarmStartupAlarm,
             hcAlarmRisingThreshAbsValueLo,
             hcAlarmRisingThreshAbsValueHi,
             hcAlarmRisingThresholdValStatus,
             hcAlarmFallingThreshAbsValueLo,
             hcAlarmFallingThreshAbsValueHi,
             hcAlarmFallingThresholdValStatus,
             hcAlarmRisingEventIndex,
             hcAlarmFallingEventIndex,
             hcAlarmValueFailedAttempts,
             hcAlarmOwner,
             hcAlarmStorageType,
             hcAlarmStatus
    }
    STATUS  current
    DESCRIPTION
            "A collection of objects used to configure entries for high
            capacity alarm threshold monitoring purposes."
    ::= { hcAlarmGroups 1 }

hcAlarmCapabilitiesGroup OBJECT-GROUP
    OBJECTS {
             hcAlarmCapabilities
    }
    STATUS  current
    DESCRIPTION
            "A collection of objects used to indicate an agent's high
            capacity alarm threshold monitoring capabilities."
    ::= { hcAlarmGroups 2 }

hcAlarmNotificationsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
            hcRisingAlarm,
            hcFallingAlarm
    }
    STATUS  current
    DESCRIPTION
            "A collection of notifications to deliver information
            related to a high capacity rising or falling threshold event



Bierman & McCloghrie        Standards Track                    [Page 20]


RFC 3434                High Capacity Alarm MIB            December 2002


            to a management application."
    ::= { hcAlarmGroups 3 }

END

6.  Intellectual Property

   The IETF takes no position regarding the validity or scope of any
   intellectual property or other rights that might be claimed to
   pertain to the implementation or use of the technology described in
   this document or the extent to which any license under such rights
   might or might not be available; neither does it represent that it
   has made any effort to identify any such rights.  Information on the
   IETF's procedures with respect to rights in standards-track and
   standards-related documentation can be found in BCP-11.  Copies of
   claims of rights made available for publication and any assurances of
   licenses to be made available, or the result of an attempt made to
   obtain a general license or permission for the use of such
   proprietary rights by implementors or users of this specification can
   be obtained from the IETF Secretariat.

   The IETF invites any interested party to bring to its attention any
   copyrights, patents or patent applications, or other proprietary
   rights which may cover technology that may be required to practice
   this standard.  Please address the information to the IETF Executive
   Director.

7.  Acknowledgements

   This memo is a product of the RMONMIB working group, and is based on
   existing alarmTable objects in the RMON-1 MIB module [RFC2819].  In
   order to maintain the RMON 'look-and-feel' and semantic consistency,
   some of Steve Waldbusser's text from [RFC2819] has been adapted for
   use in this MIB.

8.  Normative References

   [RFC2026] Bradner, S., "The Internet Standards Process -- Revision
             3", BCP 9, RFC 2026, October 1996.

   [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
             Requirement Levels", BCP 14, RFC 2119, March 1997.









Bierman & McCloghrie        Standards Track                    [Page 21]


RFC 3434                High Capacity Alarm MIB            December 2002


   [RFC2578] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
             Rose, M. and S. Waldbusser, "Structure of Management
             Information Version 2 (SMIv2)", STD 58, RFC 2578, April
             1999.

   [RFC2579] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
             Rose, M. and S. Waldbusser, "Textual Conventions for
             SMIv2", STD 58, RFC 2579, April 1999.

   [RFC2580] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
             Rose, M. and S. Waldbusser, "Conformance Statements for
             SMIv2", RFC 2580, STD 58, April 1999.

   [RFC2819] Waldbusser, S., "Remote Network Monitoring Management
             Information Base", STD 59, RFC 2819, May 2000.

   [RFC3414] Blumenthal, U. and B. Wijnen, "User-based Security Model
             (USM) for version 3 of the Simple Network Management
             Protocol (SNMPv3)", STD 62, RFC 3414, December 2002.

   [RFC3415] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based
             Access Control Model (VACM) for the Simple Network
             Management Protocol (SNMP)", STD 62, RFC 3415, December
             2002.

9.  Informative References

   [RFC3410] Case, J., Mundy, R., Partain, D. and B. Stewart,
             "Introduction and Applicability Statements for Internet-
             Standard Management Framework", RFC 3410, December 2002.

   [RFC2863] McCloghrie, K. and F. Kastenholz, "The Interfaces Group
             MIB", RFC 2863, June, 2000.

10.  Security Considerations

   There are a number of management objects defined in this MIB that
   have a MAX-ACCESS clause of read-write and/or read-create.  Such
   objects may be considered sensitive or vulnerable in some network
   environments.  The support for SET operations in a non-secure
   environment without proper protection can have a negative effect on
   network operations.

   There are a number of managed objects in this MIB that may contain
   sensitive information. These are:

        hcAlarmAbsValue
        hcAlarmValueStatus



Bierman & McCloghrie        Standards Track                    [Page 22]


RFC 3434                High Capacity Alarm MIB            December 2002


   These objects are used together, and may expose the values of
   particular MIB instances, as identified by associated instances of
   the hcAlarmVariable object.

        hcAlarmVariable

   This object identifies the object instance that the associated
   hcAlarmEntry will periodically sample.  Because SNMP access control
   is articulated entirely in terms of the contents of MIB views, no
   access control mechanism exists that can restrict the value of this
   object to identify only those objects that exist in a particular MIB
   view.  Thus, because there is no acceptable means of restricting the
   read access that could be obtained through the alarm mechanism, the
   probe must only grant write access to this object in those views that
   have read access to all objects on the probe.

   SNMPv1 by itself is not a secure environment.  Even if the network
   itself is secure (for example by using IPSec), there is no control as
   to who on the secure network is allowed to access and GET/SET
   (read/change/create/delete) the objects in this MIB.

   It is recommended that the implementors consider the security
   features as provided by the SNMPv3 framework.  Specifically, the use
   of the User-based Security Model STD 62, RFC 3414 [RFC3414] and the
   View-based Access Control Model STD 62, RFC 3415 [RFC3415] is
   recommended.

   It is then a customer/user responsibility to ensure that the SNMP
   entity giving access to an instance of this MIB, is properly
   configured to give access to only the objects, and to those
   principals (users) that have legitimate rights to indeed GET or SET
   (change/create/delete) them.

11.  Authors' Addresses

   Andy Bierman
   Cisco Systems, Inc.
   170 West Tasman Drive
   San Jose, CA USA 95134
   Phone: +1 408-527-3711
   EMail: abierman@cisco.com

   Keith McCloghrie
   Cisco Systems, Inc.
   170 West Tasman Drive
   San Jose, CA USA 95134
   Phone: +1 408-526-5260
   EMail: kzm@cisco.com



Bierman & McCloghrie        Standards Track                    [Page 23]


RFC 3434                High Capacity Alarm MIB            December 2002


12.  Full Copyright Statement

   Copyright (C) The Internet Society (2002).  All Rights Reserved.

   This document and translations of it may be copied and furnished to
   others, and derivative works that comment on or otherwise explain it
   or assist in its implementation may be prepared, copied, published
   and distributed, in whole or in part, without restriction of any
   kind, provided that the above copyright notice and this paragraph are
   included on all such copies and derivative works.  However, this
   document itself may not be modified in any way, such as by removing
   the copyright notice or references to the Internet Society or other
   Internet organizations, except as needed for the purpose of
   developing Internet standards in which case the procedures for
   copyrights defined in the Internet Standards process must be
   followed, or as required to translate it into languages other than
   English.

   The limited permissions granted above are perpetual and will not be
   revoked by the Internet Society or its successors or assigns.

   This document and the information contained herein is provided on an
   "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
   TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
   BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
   HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Acknowledgement

   Funding for the RFC Editor function is currently provided by the
   Internet Society.



















Bierman & McCloghrie        Standards Track                    [Page 24]

mirror server hosted at Truenetwork, Russian Federation.